ACIQ heat pump efficiency: 161 outdoor models compared
ACIQ has 161 heat pump outdoor models certified with this refrigerant group, in 6,584 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes ACIQ makes. ACIQ has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 161
- AHRI certifications
- 6,584
- Efficiency index
- 47%
- Typical model vs same-size, same-type peers (177 models)
- Meet CEE 2025
- 41%
- 66 models
How ACIQ compares with comparable models
- ACIQ
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index177 models scored | 47% | Not ranked | — |
| COP at 5°F177 models scored | 48% | Not ranked | 1.94 |
| Capacity retention at 5°F177 models scored | 43% | Not ranked | 59% |
| HSPF2183 models scored | 44% | Not ranked | 8.1 |
| SEER2183 models scored | 45% | Not ranked | 16.0 |
| EER2183 models scored | 50% | Not ranked | 11.1 |
| Heating capacity at 5°F177 models scored | 44% | Not ranked | 19,100 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 41% | 66 |
| CEE 2026 Tier 1 (Split ASHP) | 34.2% | 55 |
| CEE Advanced Tier (Split ASHP) | 1.2% | 2 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 31.7% | 51 |
| DOE Cold Climate Heat Pump Challenge | 1.2% | 2 |
| ENERGY STAR Cold Climate | 19.3% | 31 |
Sizes and duct types offered
- ACIQ (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 14 | 50% | 52% | 47% | 48% |
| Ducted, 2 tons | 23 | 45% | 48% | 45% | 45% |
| Ducted, 2.5–3 tons | 40 | 43% | 49% | 39% | 40% |
| Ducted, 3.5–4.5 tons | 52 | 46% | 50% | 43% | 44% |
| Ducted, 5 tons and up | 5 | 48% | 57% | 38% | 32% |
| Non-ducted, up to 1.5 tons | 22 | 52% | 43% | 51% | 56% |
| Non-ducted, 2 tons | 6 | 52% | 52% | 57% | 51% |
| Non-ducted, 2.5–3 tons | 14 | 51% | 40% | 43% | 44% |
| Non-ducted, 3.5–4.5 tons | 7 | 48% | 38% | 48% | 51% |
Every ACIQ model in the market
- ACIQ models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top ACIQ models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ACIQ-06ZPL-HP230BACIQ · ACIQwith ductless indoor unit ACIQ-06W-HH-MC | 0.5 tons6,000 Btu/h · Non-ducted | 107% | 2.09 | 13.6 | 7,500 | 26.5 | CEE 25CEE 26XcelES CC | 2 | 210857314 | Non-ducted, up to 1.5 tons | 89.3 |
| 2ACIQ-18-HPBACIQ · ACIQ serieswith ducted air handler ACIQ-18W-WM | 1.5 tons18,000 Btu/h · Ducted | 99% | 2.30 | 10.8 | 18,800 | 19.3 | CEE 25CEE 26XcelES CC | 5 | 213433248 | Ducted, up to 1.5 tons | 86.9 |
| 3ACIQ-48ZPL-HP230BACIQ · ACIQwith ducted air handler ACIQ-48CD-HH-MB | 4 tons48,000 Btu/h · Ducted | 88% | 2.02 | 10.3 | 46,000 | 14.3 | None | 3 | 210857322 | Ducted, 3.5–4.5 tons | 86.4 |
| 4ACIQ-24ZPL-HP230BACIQ · ACIQwith ductless indoor unit ACIQ-24FM-HH-MB | 2 tons24,000 Btu/h · Non-ducted | 100% | 2.10 | 11.0 | 25,000 | 20.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 5 | 207825544 | Non-ducted, 2 tons | 85.4 |
| 5ACIQ-60ZPL-HP230BACIQ · ACIQwith ducted air handler ACIQ-60CD-HH-MB | 4.5 tons55,000 Btu/h · Ducted | 93% | 1.97 | 9.5 | 53,000 | 15.8 | ES CC | 2 | 210857323 | Ducted, 3.5–4.5 tons | 82.0 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ACIQ-06ZPL-HP230BACIQ · ACIQwith ductless indoor unit ACIQ-06W-HH-MC | 0.5 tons6,000 Btu/h · Non-ducted | 107% | 2.09 | 13.6 | 26.5 | 15.8 | CEE 25CEE 26XcelES CC | 2 | 210857314 | Non-ducted, up to 1.5 tons | 92.0 | 89.3 | 94.7 | 89.3 |
| 2SC-09ZPL-HP230ACIQwith ductless indoor unit SC-09WPL-HP230 | 1 ton9,000 Btu/h · Non-ducted | 144% | 1.91 | 11.0 | 27.0 | 16.6 | CEE 25CEE 26Xcel | 1 | 208650735 | Non-ducted, up to 1.5 tons | 88.7 | 80.1 | 97.3 | 80.1 |
| 3ACIQ-09ZPL-HP230BACIQ · ACIQwith ductless indoor unit ACIQ-09W-HH-MB | 1 ton9,000 Btu/h · Non-ducted | 88% | 1.97 | 11.5 | 28.1 | 16.2 | CEE 25CEE 26XcelES CC | 5 | 207825531 | Non-ducted, up to 1.5 tons | 87.0 | 76.2 | 97.9 | 76.2 |
| 4ACIQ-09ZPL-HP230BACIQ · ACIQwith ducted air handler ACIQ-09CD-HH-MB | 1 ton9,000 Btu/h · Ducted | 108% | 1.90 | 12.0 | 20.2 | 13.2 | CEE 25CEE 26XcelES CC | 5 | 207825538 | Ducted, up to 1.5 tons | 85.2 | 74.9 | 95.5 | 74.9 |
| 5ACIQ-24ZPL-HP230BACIQ · ACIQwith ductless indoor unit ACIQ-24W-HH-MB | 2 tons24,000 Btu/h · Non-ducted | 86% | 2.21 | 11.4 | 21.5 | 13.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 5 | 207825534 | Non-ducted, 2 tons | 84.3 | 84.5 | 84.1 | 85.4 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | R4H5S30*K*AAA* | 2.57 | Ducted, 2.5–3 tons | 93% | 215415939 |
| Capacity retention at 5°F | HVH837GKA2* | 140% | Ducted, 2.5–3 tons | 100% | 213067201 |
| HSPF2 | ACIQ-48ZPL-HP230B | 10.3 | Ducted, 3.5–4.5 tons | 99% | 210857322 |
| SEER2 | ES-27Z-M3B | 24.6 | Non-ducted, 2.5–3 tons | 99% | 210857386 |
| EER2 | SC-09ZPL-HP230 | 16.6 | Non-ducted, up to 1.5 tons | 99% | 208650735 |
| Heating capacity at 5°F | ACIQ-60ZPL-HP230B | 56,500 Btu/h | Non-ducted, 3.5–4.5 tons | 99% | 210857326 |
ACIQ size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 86.9(50 is the typical model of its size class)ACIQ-18-HPBwith ducted air handler ACIQ-18W-WM9 of 14 models qualify · AHRI 213433248 | 85.2(50 is the typical model of its size class)ACIQ-09ZPL-HP230Bwith ducted air handler ACIQ-09CD-HH-MB14 of 14 models have all five ratings · AHRI 207825538 |
| Ducted, 2 tons | 79.4(50 is the typical model of its size class)ACIQ-24ZPL-HP230Bwith ducted air handler ACIQ-24CD-HH-MB9 of 22 models qualify · AHRI 207825541 | 80.1(50 is the typical model of its size class)ACIQ-24ZPL-HP230Bwith ducted air handler ACIQ-24CD-HH-MB23 of 23 models have all five ratings · AHRI 207825541 |
| Ducted, 2.5–3 tons | 79.9(50 is the typical model of its size class)ACIQ-36ZPL-HP230Bwith ducted air handler ACIQ-36CD-HH-MB14 of 41 models qualify · AHRI 210857321 | 75.4(50 is the typical model of its size class)ES-27Z-M3B40 of 40 models have all five ratings · AHRI 210857387 |
| Ducted, 3.5–4.5 tons | 86.4(50 is the typical model of its size class)ACIQ-48ZPL-HP230Bwith ducted air handler ACIQ-48CD-HH-MB11 of 52 models qualify · AHRI 210857322 | 82.0(50 is the typical model of its size class)ACIQ-48Z-HH-M5B50 of 53 models have all five ratings · AHRI 207825586 |
| Ducted, 5 tons and up | None on this board (0 of 5 models qualify) | 54.0(50 is the typical model of its size class)H4H5S60*K*AAA*with ducted air handler FJMA4*60L*D4 of 4 models have all five ratings · AHRI 213069077 |
| Non-ducted, up to 1.5 tons | 89.3(50 is the typical model of its size class)ACIQ-06ZPL-HP230Bwith ductless indoor unit ACIQ-06W-HH-MC16 of 22 models qualify · AHRI 210857314 | 92.0(50 is the typical model of its size class)ACIQ-06ZPL-HP230Bwith ductless indoor unit ACIQ-06W-HH-MC22 of 22 models have all five ratings · AHRI 210857314 |
| Non-ducted, 2 tons | 85.4(50 is the typical model of its size class)ACIQ-24ZPL-HP230Bwith ductless indoor unit ACIQ-24FM-HH-MB4 of 6 models qualify · AHRI 207825544 | 84.3(50 is the typical model of its size class)ACIQ-24ZPL-HP230Bwith ductless indoor unit ACIQ-24W-HH-MB6 of 6 models have all five ratings · AHRI 207825534 |
| Non-ducted, 2.5–3 tons | 79.3(50 is the typical model of its size class)ACIQ-36Z-HH-M4B6 of 14 models qualify · AHRI 207825582 | 82.8(50 is the typical model of its size class)ACIQ-36Z-HH-M4B11 of 14 models have all five ratings · AHRI 207825582 |
| Non-ducted, 3.5–4.5 tons | 76.8(50 is the typical model of its size class)ACIQ-60ZPL-HP230Bwith ductless indoor unit ACIQ-60FM-HH-MB5 of 7 models qualify · AHRI 210857326 | 77.9(50 is the typical model of its size class)ACIQ-48Z-HH-M5B7 of 7 models have all five ratings · AHRI 207825585 |
Newest ACIQ certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| SC-27Z-HH-M4BACIQ · Extreme Heat | 2 tons23,200 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 90% | 10.0 | 21.0 | CEE 25CEE 26XcelES CC | 3 | 215742358 |
| ACIQ-30-HPBACIQ · ACIQ Serieswith ducted air handler ACIQ-30-AHB | 2.5 tons30,000 Btu/h · Ducted | 1.80 | 73% | 8.9 | 16.2 | CEE 25CEE 26XcelES CC | 11 | 215570365 |
| R4H5S30*K*AAA*ACIQwith ducted air handler ACIQ-3619UDXBCB+ACIQ-EF1520FD-MH | 2.5 tons27,200 Btu/h · Ducted | 2.57 | 55% | 7.6 | 14.5 | None | 172 | 215426598 |
| R4H5S24*K*AAA*ACIQwith ducted air handler ACIQ-2413UDPBCA+ACIQ-EF1520FD-MH | 2 tons22,400 Btu/h · Ducted | 2.50 | 57% | 7.5 | 15.0 | None | 71 | 215426597 |
| R4H5S18*K*AAA*ACIQwith ducted air handler ACIQ-2413UDPBCA+ACIQ-EF1520FD-MH | 1.5 tons16,900 Btu/h · Ducted | 2.34 | 51% | 7.7 | 14.3 | None | 111 | 215426596 |
Compare ACIQ