AIR-CON heat pump efficiency: 65 outdoor models compared
AIR-CON has 65 heat pump outdoor models certified with this refrigerant group, in 87 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes AIR-CON makes. AIR-CON has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 65
- AHRI certifications
- 87
- Efficiency index
- 55%
- Typical model vs same-size, same-type peers (57 models)
- Meet CEE 2025
- 55.4%
- 36 models
How AIR-CON compares with comparable models
- AIR-CON
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index57 models scored | 55% | Not ranked | — |
| COP at 5°F57 models scored | 47% | Not ranked | 1.87 |
| Capacity retention at 5°F57 models scored | 52% | Not ranked | 74% |
| HSPF279 models scored | 46% | Not ranked | 8.8 |
| SEER279 models scored | 54% | Not ranked | 19.0 |
| EER279 models scored | 50% | Not ranked | 11.5 |
| Heating capacity at 5°F57 models scored | 50% | Not ranked | 15,500 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 55.4% | 36 |
| CEE 2026 Tier 1 (Split ASHP) | 55.4% | 36 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 49.2% | 32 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 38.5% | 25 |
Sizes and duct types offered
- AIR-CON (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 5 | 49% | 47% | 42% | 53% |
| Ducted, 2 tons | 6 | 53% | 34% | 51% | 62% |
| Ducted, 2.5–3 tons | 9 | 56% | 44% | 51% | 61% |
| Ducted, 3.5–4.5 tons | 11 | 55% | 33% | 51% | 62% |
| Ducted, 5 tons and up | 1 | 52% | 41% | 60% | 96% |
| Non-ducted, up to 1.5 tons | 27 | 61% | 51% | 44% | 54% |
| Non-ducted, 2 tons | 9 | 52% | 48% | 45% | 46% |
| Non-ducted, 2.5–3 tons | 8 | 46% | 51% | 40% | 34% |
| Non-ducted, 3.5–4.5 tons | 2 | 53% | 68% | 41% | 65% |
| Non-ducted, 5 tons and up | 1 | 36% | 69% | 42% | 42% |
Every AIR-CON model in the market
- AIR-CON models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top AIR-CON models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ASLCI4H4S36AIR-CON · Sky Prowith ducted air handler ASLEK4H4S36 | 3 tons36,000 Btu/h · Ducted | 76% | 2.20 | 9.5 | 27,400 | 17.5 | CEE 25CEE 26Xcel | 2 | 205150424 | Ducted, 2.5–3 tons | 78.1 |
| 2ASLCI4H4S36AIR-CON · Sky Prowith ductless indoor unit ASLEC4H4S36 | 3 tons36,000 Btu/h · Non-ducted | 74% | 2.28 | 9.8 | 26,800 | 18.0 | CEE 25CEE 26Xcel | 2 | 205150423 | Non-ducted, 2.5–3 tons | 77.2 |
| 3ASLCI4H4S09AIR-CON · Sky Prowith ductless indoor unit ASLEC4H4S09 | 1 ton9,000 Btu/h · Non-ducted | 83% | 2.25 | 10.0 | 8,300 | 20.5 | CEE 25CEE 26XcelES CC | 2 | 205129515 | Non-ducted, up to 1.5 tons | 76.9 |
| 4ASDDI4H4S36AIR-CON · SD Premiumwith ducted air handler ASDVI4H4S36 | 3 tons34,000 Btu/h · Ducted | 76% | 2.05 | 9.5 | 26,000 | 18.0 | CEE 25CEE 26XcelES CC | 1 | 207026915 | Ducted, 2.5–3 tons | 75.1 |
| 5ABZCI4H4S09AIR-CON · Blizzardwith ductless indoor unit ABZEM4H4S09 | 1 ton9,000 Btu/h · Non-ducted | 81% | 2.05 | 10.5 | 8,050 | 27.5 | CEE 25CEE 26XcelES CC | 1 | 10272500 | Non-ducted, up to 1.5 tons | 73.2 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ABZCI4H4S09AIR-CON · Blizzardwith ductless indoor unit ABZEM4H4S09 | 1 ton9,000 Btu/h · Non-ducted | 81% | 2.05 | 10.5 | 27.5 | 15.5 | CEE 25CEE 26XcelES CC | 1 | 10272500 | Non-ducted, up to 1.5 tons | 84.2 | 73.2 | 95.1 | 73.2 |
| 2ABHCI4H4S09AIR-CON · Blue Hyperwith ductless indoor unit ABHEM4H4S09 | 1 ton9,000 Btu/h · Non-ducted | 86% | 1.94 | 10.5 | 25.5 | 14.5 | CEE 25CEE 26XcelES CC | 1 | 211583437 | Non-ducted, up to 1.5 tons | 80.1 | 70.3 | 89.9 | 70.3 |
| 3AMSCI4H4S36AIR-CON · Multi Split | 2.5 tons32,000 Btu/h · Ducted | 96% | 1.84 | 8.9 | 19.5 | 12.0 | CEE 25CEE 26XcelES CC | 3 | 204462799 | Ducted, 2.5–3 tons | 77.7 | 67.4 | 88.0 | 67.4 |
| 4ABZCI4H4S12AIR-CON · Blizzardwith ductless indoor unit ABZEM4H4S12 | 1 ton12,000 Btu/h · Non-ducted | 81% | 1.95 | 9.8 | 23.5 | 15.4 | CEE 25CEE 26XcelES CC | 1 | 10272501 | Non-ducted, up to 1.5 tons | 75.3 | 63.9 | 86.7 | 63.9 |
| 5AMSCI4H4S24AIR-CON · Multi Split | 2 tons24,000 Btu/h · Ducted | 100% | 1.84 | 8.6 | 21.0 | 12.1 | CEE 25CEE 26XcelES CC | 3 | 204462798 | Ducted, 2 tons | 72.2 | 56.5 | 87.9 | 56.5 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | CH4H6C36KN-AE | 2.30 | Non-ducted, 2.5–3 tons | 97% | 215746268 |
| Capacity retention at 5°F | APIV4H4R04 | 98% | Ducted, 3.5–4.5 tons | 97% | 215493894 |
| HSPF2 | ASLCI4H4S36 | 9.5 | Ducted, 2.5–3 tons | 83% | 205150424 |
| SEER2 | ABZCI4H4S09 | 27.5 | Non-ducted, up to 1.5 tons | 96% | 10272500 |
| EER2 | ABZCI4H4S09 | 15.5 | Non-ducted, up to 1.5 tons | 93% | 10272500 |
| Heating capacity at 5°F | AMSCI4H4S18 | 18,000 Btu/h | Non-ducted, up to 1.5 tons | 92% | 205150432 |
AIR-CON size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 51.6(50 is the typical model of its size class)ASLCI4H4S09with ducted air handler ASLEK4H4S093 of 5 models qualify · AHRI 205129516 | 55.5(50 is the typical model of its size class)ASLCI4H4S09with ducted air handler ASLEK4H4S094 of 5 models have all five ratings · AHRI 205129516 |
| Ducted, 2 tons | 64.8(50 is the typical model of its size class)ASLCI4H4S24with ducted air handler ASLEK4H4S243 of 6 models qualify · AHRI 205129522 | 72.2(50 is the typical model of its size class)AMSCI4H4S244 of 6 models have all five ratings · AHRI 204462798 |
| Ducted, 2.5–3 tons | 78.1(50 is the typical model of its size class)ASLCI4H4S36with ducted air handler ASLEK4H4S364 of 9 models qualify · AHRI 205150424 | 77.7(50 is the typical model of its size class)AMSCI4H4S366 of 9 models have all five ratings · AHRI 204462799 |
| Ducted, 3.5–4.5 tons | 62.4(50 is the typical model of its size class)APIV4H4R044 of 11 models qualify · AHRI 215493894 | 66.7(50 is the typical model of its size class)APIV4H4R046 of 11 models have all five ratings · AHRI 215493894 |
| Ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 51.7(50 is the typical model of its size class)CH4H6C60KN-AE1 of 1 models have all five ratings · AHRI 215746273 |
| Non-ducted, up to 1.5 tons | 76.9(50 is the typical model of its size class)ASLCI4H4S09with ductless indoor unit ASLEC4H4S0919 of 27 models qualify · AHRI 205129515 | 84.2(50 is the typical model of its size class)ABZCI4H4S09with ductless indoor unit ABZEM4H4S0921 of 27 models have all five ratings · AHRI 10272500 |
| Non-ducted, 2 tons | 68.3(50 is the typical model of its size class)ASLCI4H4S24with ductless indoor unit ASLEC4H4S244 of 9 models qualify · AHRI 205129521 | 71.3(50 is the typical model of its size class)AMSCI4H4S247 of 9 models have all five ratings · AHRI 204462794 |
| Non-ducted, 2.5–3 tons | 77.2(50 is the typical model of its size class)ASLCI4H4S36with ductless indoor unit ASLEC4H4S362 of 8 models qualify · AHRI 205150423 | 68.1(50 is the typical model of its size class)AMSCI4H4S365 of 8 models have all five ratings · AHRI 204462795 |
| Non-ducted, 3.5–4.5 tons | 42.4(50 is the typical model of its size class)AMSCI4H4S421 of 2 models qualify · AHRI 205150426 | 61.0(50 is the typical model of its size class)CH4H6C48KN-AE2 of 2 models have all five ratings · AHRI 215746269 |
| Non-ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 36.2(50 is the typical model of its size class)CH4H6C60KN-AE1 of 1 models have all five ratings · AHRI 215746270 |
Newest AIR-CON certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| CH4H6C28KN-AEAIR-CON | 2.5 tons28,000 Btu/h · Ducted and non-ducted | 1.70 | 41% | 8.5 | 18.0 | None | 2 | 215746277 |
| CH4H6C24KN-AEAIR-CON | 2 tons24,000 Btu/h · Ducted and non-ducted | 1.80 | 48% | 8.5 | 18.0 | None | 2 | 215746276 |
| CH4H6C60KN-AEAIR-CON | 5 tons60,000 Btu/h · Ducted and non-ducted | 1.90 | 48% | 8.3 | 18.0 | None | 2 | 215746273 |
| CH4H6C48KN-AEAIR-CON | 4 tons48,000 Btu/h · Ducted and non-ducted | 1.90 | 48% | 8.3 | 16.0 | None | 2 | 215746272 |
| CH4H6C36KN-AEAIR-CON | 3 tons37,600 Btu/h · Ducted and non-ducted | 1.80 | 48% | 8.0 | 18.0 | CEE 25CEE 26 | 2 | 215746271 |
Compare AIR-CON
AIR-CON includes these brand names as listed in AHRI: AIR-CON. Standards are checked against published thresholds; program rules beyond ratings are not checked.