- Insights
- Manufacturers
- AIR-CON
Both views use the same certified data. This device remembers your choice.
AIR-CON heat pump efficiency: 42 outdoor models compared
AIR-CON has 42 heat pump outdoor models certified with this refrigerant group, in 65 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes AIR-CON makes. AIR-CON has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 42
- AHRI certifications
- 65
- Efficiency index
- 45%
- Typical model vs same-size, same-type peers (35 models)
- Meet CEE 2025
- 42.9%
- 18 models
How AIR-CON compares with comparable models
- AIR-CON
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index35 models scored | 45% | Not ranked | — |
| COP at 5°F35 models scored | 56% | Not ranked | 2.00 |
| Capacity retention at 5°F35 models scored | 33% | Not ranked | 70% |
| HSPF249 models scored | 45% | Not ranked | 8.6 |
| SEER249 models scored | 42% | Not ranked | 17.0 |
| EER249 models scored | 40% | Not ranked | 11.3 |
| Heating capacity at 5°F35 models scored | 42% | Not ranked | 20,550 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 42.9% | 18 |
| CEE 2026 Tier 1 (Split ASHP) | 35.7% | 15 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 33.3% | 14 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- AIR-CON (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 3 | 79% | 93% | 42% | 43% |
| Ducted, 2 tons | 4 | 75% | 60% | 42% | 45% |
| Ducted, 2.5 to 3 tons | 10 | 54% | 58% | 48% | 50% |
| Ducted, 3.5 to 4.5 tons | 14 | 57% | 64% | 53% | 51% |
| Ducted, 5 tons and up | 1 | 66% | 90% | 94% | 76% |
| Non-ducted, up to 1.5 tons | 7 | 21% | 31% | 34% | 13% |
| Non-ducted, 2 tons | 3 | 33% | 41% | 60% | 25% |
| Non-ducted, 2.5 to 3 tons | 3 | 41% | 64% | 43% | 42% |
| Non-ducted, 3.5 to 4.5 tons | 4 | 32% | 65% | 12% | 38% |
Every AIR-CON model in the market
- AIR-CON models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top AIR-CON models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ASGCI8H4M24AIR-CONwith ductless indoor unit ASGEL8H4M24 | 2 tons24,000 Btu/h · Non-ducted | 76% | 2.27 | 11.1 | 18,600 | 21.1 | CEE 25CEE 26Xcel | 2 | 217291584 | Non-ducted, 2 tons | 79.3 |
| 2AASDCI7H4R60AIR-CON · G Serieswith ducted air handler AASDEM7H4R60-S | 4.5 tons53,500 Btu/h · Ducted | 74% | 2.24 | 9.5 | 40,000 | 18.8 | CEE 25CEE 26Xcel | 2 | 217655822 | Ducted, 3.5 to 4.5 tons | 73.7 |
| 3AVDCI7H4T48AIR-CON · SATURN INVERTERwith ducted air handler AVDEM7H4T48 | 4 tons47,000 Btu/h · Ducted | 72% | 2.30 | 9.2 | 34,000 | 18.5 | CEE 25CEE 26Xcel | 1 | 217548265 | Ducted, 3.5 to 4.5 tons | 72.3 |
| 4ASGCI8H4M18AIR-CONwith ducted air handler ASGEK8H4M18 | 1.5 tons17,500 Btu/h · Ducted | 71% | 2.41 | 11.3 | 14,200 | 20.0 | CEE 25CEE 26Xcel | 3 | 217291581 | Ducted, up to 1.5 tons | 70.9 |
| 5AVDCI7H4T60AIR-CON · SATURN INVERTERwith ducted air handler AVDEM7H4T60 | 4.5 tons55,000 Btu/h · Ducted | 73% | 2.30 | 8.8 | 40,000 | 18.0 | CEE 25CEE 26Xcel | 1 | 217548266 | Ducted, 3.5 to 4.5 tons | 69.7 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ASGCI8H4M18AIR-CONwith ducted air handler ASGEK8H4M18 | 1.5 tons17,500 Btu/h · Ducted | 71% | 2.41 | 11.3 | 20.0 | 13.3 | CEE 25CEE 26Xcel | 3 | 217291581 | Ducted, up to 1.5 tons | 79.2 | 70.9 | 87.4 | 70.9 |
| 2AASDCI7H4R60AIR-CON · G Serieswith ducted air handler AASDEM7H4R48-S | 4 tons48,000 Btu/h · Ducted | 75% | 2.18 | 9.5 | 20.0 | 11.7 | CEE 25CEE 26Xcel | 2 | 217655825 | Ducted, 3.5 to 4.5 tons | 78.4 | 73.1 | 83.8 | 73.7 |
| 3AVDCI7H4T24AIR-CON · SATURN INVERTERwith ducted air handler AVDEM7H4T24 | 2 tons24,000 Btu/h · Ducted | 79% | 2.15 | 9.5 | 19.0 | 13.2 | CEE 25CEE 26Xcel | 1 | 217548263 | Ducted, 2 tons | 76.5 | 67.6 | 85.3 | 67.6 |
| 4AVDCI7H4T48AIR-CON · SATURN INVERTERwith ducted air handler AVDEM7H4T48 | 4 tons47,000 Btu/h · Ducted | 72% | 2.30 | 9.2 | 18.5 | 11.5 | CEE 25CEE 26Xcel | 1 | 217548265 | Ducted, 3.5 to 4.5 tons | 73.3 | 72.3 | 74.4 | 72.3 |
| 5AVPI7H4T24AIR-CON | 2 tons24,000 Btu/h · Ducted | 103% | 2.00 | 9.0 | 19.0 | 12.3 | CEE 25CEE 26Xcel | 1 | 218644490 | Ducted, 2 tons | 73.3 | 68.3 | 78.3 | 68.3 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | CH7H6C48KN-AE | 2.20 | Non-ducted, 3.5 to 4.5 tons | 97% | 217643038 |
| Capacity retention at 5°F | AVPI7H4T24 | 103% | Ducted, 2 tons | 96% | 218644490 |
| HSPF2 | ASGCI8H4M60 | 9.7 | Ducted, 5 tons and up | 94% | 217291590 |
| SEER2 | CH7H6C48KN-AE | 24.0 | Non-ducted, 3.5 to 4.5 tons | 94% | 217643038 |
| EER2 | CH7H6C36KN-AE | 14.0 | Non-ducted, 2.5 to 3 tons | 97% | 217643037 |
| Heating capacity at 5°F | AVPI7H4T24 | 24,600 Btu/h | Ducted, 2 tons | 94% | 218644490 |
AIR-CON size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 70.9(50 is the typical model of its size class)ASGCI8H4M18with ducted air handler ASGEK8H4M181 of 3 models qualify · AHRI 217291581 | 79.2(50 is the typical model of its size class)ASGCI8H4M18with ducted air handler ASGEK8H4M181 of 3 models have all five ratings · AHRI 217291581 |
| Ducted, 2 tons | 68.3(50 is the typical model of its size class)AVPI7H4T242 of 4 models qualify · AHRI 218644490 | 76.5(50 is the typical model of its size class)AVDCI7H4T24with ducted air handler AVDEM7H4T242 of 4 models have all five ratings · AHRI 217548263 |
| Ducted, 2.5 to 3 tons | 64.6(50 is the typical model of its size class)AVPI7H4T363 of 10 models qualify · AHRI 218644491 | 58.3(50 is the typical model of its size class)AVPI7H4T366 of 10 models have all five ratings · AHRI 218644491 |
| Ducted, 3.5 to 4.5 tons | 73.7(50 is the typical model of its size class)AASDCI7H4R60with ducted air handler AASDEM7H4R60-S6 of 14 models qualify · AHRI 217655822 | 78.4(50 is the typical model of its size class)AASDCI7H4R60with ducted air handler AASDEM7H4R48-S8 of 14 models have all five ratings · AHRI 217655825 |
| Ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 65.9(50 is the typical model of its size class)ASGCI8H4M60with ducted air handler ASGEK8H4M601 of 1 models have all five ratings · AHRI 217291590 |
| Non-ducted, up to 1.5 tons | 69.5(50 is the typical model of its size class)ASGCI8H4M18with ductless indoor unit ASGEC8H4M181 of 7 models qualify · AHRI 217291580 | 62.0(50 is the typical model of its size class)ASGCI8H4M18with ductless indoor unit ASGEL8H4M187 of 7 models have all five ratings · AHRI 217291582 |
| Non-ducted, 2 tons | 79.3(50 is the typical model of its size class)ASGCI8H4M24with ductless indoor unit ASGEL8H4M241 of 3 models qualify · AHRI 217291584 | 71.3(50 is the typical model of its size class)ASGCI8H4M24with ductless indoor unit ASGEL8H4M243 of 3 models have all five ratings · AHRI 217291584 |
| Non-ducted, 2.5 to 3 tons | 63.6(50 is the typical model of its size class)ASGCI8H4M36with ductless indoor unit ASGEC8H4M361 of 3 models qualify · AHRI 217291586 | 69.8(50 is the typical model of its size class)CH7H6C36KN-AE3 of 3 models have all five ratings · AHRI 217643037 |
| Non-ducted, 3.5 to 4.5 tons | 55.8(50 is the typical model of its size class)ASGCI8H4M48with ductless indoor unit ASGEC8H4M481 of 4 models qualify · AHRI 217291589 | 58.5(50 is the typical model of its size class)CH7H6C48KN-AE4 of 4 models have all five ratings · AHRI 217643038 |
Newest AIR-CON certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| AVPI7H4T60AIR-CON | 4.5 tons56,000 Btu/h · Ducted | 2.00 | 71% | 8.8 | 17.0 | CEE 25CEE 26Xcel | 1 | 218644493 |
| AVPI7H4T48AIR-CON | 4 tons48,000 Btu/h · Ducted | 2.10 | 73% | 8.8 | 18.0 | CEE 25CEE 26Xcel | 1 | 218644492 |
| AVPI7H4T36AIR-CON | 3 tons33,000 Btu/h · Ducted | 2.00 | 85% | 9.0 | 18.5 | CEE 25CEE 26Xcel | 1 | 218644491 |
| AVPI7H4T24AIR-CON | 2 tons24,000 Btu/h · Ducted | 2.00 | 103% | 9.0 | 19.0 | CEE 25CEE 26Xcel | 1 | 218644490 |
| ASQCI7H4E36AIR-CONwith ductless indoor unit ASQEM7H4E36 | 3 tons35,000 Btu/h · Non-ducted | 1.80 | 51% | 8.5 | 17.0 | None | 1 | 218082666 |
Compare AIR-CON
AIR-CON includes these brand names as listed in AHRI: AIR-CON. Standards are checked against published thresholds; program rules beyond ratings are not checked.