Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
TGM heat pump efficiency: 77 outdoor models compared
TGM has 77 heat pump outdoor models certified with this refrigerant group, in 152 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes TGM makes. TGM has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 77
- AHRI certifications
- 152
- Efficiency index
- 45%
- Typical model vs same-size, same-type peers (77 models)
- Meet CEE 2025
- 58.4%
- 45 models
How TGM compares with comparable models
- TGM
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index77 models scored | 45% | Not ranked | — |
| COP at 5°F77 models scored | 48% | Not ranked | 1.91 |
| Capacity retention at 5°F78 models scored | 42% | Not ranked | 71% |
| HSPF288 models scored | 41% | Not ranked | 8.6 |
| SEER290 models scored | 45% | Not ranked | 19.0 |
| EER290 models scored | 42% | Not ranked | 11.2 |
| Heating capacity at 5°F78 models scored | 47% | Not ranked | 14,100 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 58.4% | 45 |
| CEE 2026 Tier 1 (Split ASHP) | 57.1% | 44 |
| CEE Advanced Tier (Split ASHP) | 1.3% | 1 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 54.5% | 42 |
| DOE Cold Climate Heat Pump Challenge | 1.3% | 1 |
| ENERGY STAR Cold Climate | 20.8% | 16 |
Sizes and duct types offered
- TGM (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 5 | 62% | 61% | 41% | 57% |
| Ducted, 2 tons | 8 | 67% | 62% | 53% | 57% |
| Ducted, 2.5–3 tons | 10 | 50% | 36% | 45% | 49% |
| Ducted, 3.5–4.5 tons | 11 | 61% | 60% | 57% | 57% |
| Ducted, 5 tons and up | 2 | 69% | 60% | 84% | 87% |
| Non-ducted, up to 1.5 tons | 32 | 34% | 41% | 29% | 36% |
| Non-ducted, 2 tons | 9 | 43% | 39% | 45% | 40% |
| Non-ducted, 2.5–3 tons | 8 | 40% | 52% | 41% | 37% |
| Non-ducted, 3.5–4.5 tons | 5 | 43% | 66% | 30% | 37% |
Every TGM model in the market
- TGM models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top TGM models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ARHHBT18ASTGM · M serieswith ductless indoor unit AWHHBT18S | 1.5 tons18,000 Btu/h · Non-ducted | 82% | 2.25 | 10.5 | 15,000 | 25.0 | CEE 25CEE 26XcelES CC | 1 | 218620807 | Non-ducted, up to 1.5 tons | 79.2 |
| 2MRS5VHT24ASTGM · MRS Serieswith ductless indoor unit MUV5HT24S | 2 tons24,000 Btu/h · Non-ducted | 76% | 2.27 | 11.1 | 18,600 | 21.1 | CEE 25CEE 26XcelES CC | 3 | 216706039 | Non-ducted, 2 tons | 77.9 |
| 3ARHHBT24ASTGM · C serieswith ductless indoor unit AWHHBT24S | 2 tons22,400 Btu/h · Non-ducted | 85% | 2.10 | 10.5 | 20,400 | 25.0 | CEE 25CEE 26XcelES CC | 1 | 218620808 | Non-ducted, 2 tons | 77.4 |
| 4GMRSHT36AS4TGM · M-Series | 3 tons36,000 Btu/h · Non-ducted | 100% | 2.10 | 10.0 | 36,000 | 21.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 217284813 | Non-ducted, 2.5–3 tons | 77.2 |
| 5MRS5VHT24ASTGM · MRS Serieswith ducted air handler MFC5VHT24S | 2 tons24,000 Btu/h · Ducted | 76% | 2.30 | 11.0 | 19,000 | 19.0 | CEE 25CEE 26XcelES CC | 3 | 217274615 | Ducted, 2 tons | 77.1 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ARHHBT24ASTGM · C serieswith ductless indoor unit AWHHBT24S | 2 tons22,400 Btu/h · Non-ducted | 85% | 2.10 | 10.5 | 25.0 | 14.0 | CEE 25CEE 26XcelES CC | 1 | 218620808 | Non-ducted, 2 tons | 86.5 | 77.4 | 95.6 | 77.4 |
| 2ARHHBT18ASTGM · M serieswith ductless indoor unit AWHHBT18S | 1.5 tons18,000 Btu/h · Non-ducted | 82% | 2.25 | 10.5 | 25.0 | 14.0 | CEE 25CEE 26XcelES CC | 1 | 218620807 | Non-ducted, up to 1.5 tons | 82.9 | 79.2 | 86.7 | 79.2 |
| 3CTV520HN036ATGMwith ducted air handler CTA520C024A | 2 tons24,000 Btu/h · Ducted | 83% | 2.10 | 9.4 | 20.0 | 13.3 | CEE 25CEE 26Xcel | 2 | 217138121 | Ducted, 2 tons | 79.6 | 67.2 | 92.1 | 67.2 |
| 4MRS5VHT24ASTGM · MRS Serieswith ducted air handler MFC5VHT24S | 2 tons24,000 Btu/h · Ducted | 76% | 2.30 | 11.0 | 19.0 | 12.5 | CEE 25CEE 26XcelES CC | 3 | 217274615 | Ducted, 2 tons | 78.8 | 77.1 | 80.6 | 77.1 |
| 5MRS5VHT18ASTGM · MRS Serieswith ducted air handler MFC5VHT18S | 1.5 tons17,500 Btu/h · Ducted | 71% | 2.41 | 11.3 | 20.0 | 13.3 | CEE 25CEE 26XcelES CC | 3 | 217274613 | Ducted, up to 1.5 tons | 78.4 | 69.8 | 87.0 | 69.8 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | ARHCPT18AS | 2.50 | Non-ducted, up to 1.5 tons | 98% | 218620802 |
| Capacity retention at 5°F | MRB560HWD | 70% | Ducted, 5 tons and up | 88% | 217194656 |
| HSPF2 | MR5SVHT60AS | 9.7 | Ducted, 5 tons and up | 94% | 217274621 |
| SEER2 | TMRHT18AS2 | 22.0 | Ducted, up to 1.5 tons | 97% | 218787809 |
| EER2 | ARHHBT24AS | 14.0 | Non-ducted, 2 tons | 96% | 218620808 |
| Heating capacity at 5°F | ARHHBT18AS | 15,000 Btu/h | Non-ducted, up to 1.5 tons | 86% | 218620807 |
TGM size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 69.8(50 is the typical model of its size class)MRS5VHT18ASwith ducted air handler MFC5VHT18S3 of 5 models qualify · AHRI 217274613 | 78.4(50 is the typical model of its size class)MRS5VHT18ASwith ducted air handler MFC5VHT18S3 of 5 models have all five ratings · AHRI 217274613 |
| Ducted, 2 tons | 77.1(50 is the typical model of its size class)MRS5VHT24ASwith ducted air handler MFC5VHT24S6 of 8 models qualify · AHRI 217274615 | 79.6(50 is the typical model of its size class)CTV520HN036Awith ducted air handler CTA520C024A6 of 8 models have all five ratings · AHRI 217138121 |
| Ducted, 2.5–3 tons | 63.6(50 is the typical model of its size class)MTVC2OCN036Awith ducted air handler MTA20C036A3 of 10 models qualify · AHRI 218044247 | 72.8(50 is the typical model of its size class)MTVC2OCN036Awith ducted air handler MTA20C036A6 of 10 models have all five ratings · AHRI 218044247 |
| Ducted, 3.5–4.5 tons | 72.2(50 is the typical model of its size class)OTV18HN048Awith ducted air handler OTA18C006AAlso listed as OTV18HN060A7 of 11 models qualify · AHRI 217747072 | 72.6(50 is the typical model of its size class)OTV18HN048Awith ducted air handler OTA18C006AAlso listed as OTV18HN060A8 of 11 models have all five ratings · AHRI 217747072 |
| Ducted, 5 tons and up | 64.1(50 is the typical model of its size class)MRB560HWD1 of 2 models qualify · AHRI 217194656 | 70.5(50 is the typical model of its size class)MRB560HWD2 of 2 models have all five ratings · AHRI 217194656 |
| Non-ducted, up to 1.5 tons | 79.2(50 is the typical model of its size class)ARHHBT18ASwith ductless indoor unit AWHHBT18S22 of 32 models qualify · AHRI 218620807 | 82.9(50 is the typical model of its size class)ARHHBT18ASwith ductless indoor unit AWHHBT18S32 of 32 models have all five ratings · AHRI 218620807 |
| Non-ducted, 2 tons | 77.9(50 is the typical model of its size class)MRS5VHT24ASwith ductless indoor unit MUV5HT24S6 of 9 models qualify · AHRI 216706039 | 86.5(50 is the typical model of its size class)ARHHBT24ASwith ductless indoor unit AWHHBT24S9 of 9 models have all five ratings · AHRI 218620808 |
| Non-ducted, 2.5–3 tons | 77.2(50 is the typical model of its size class)GMRSHT36AS46 of 8 models qualify · AHRI 217284813 | 64.5(50 is the typical model of its size class)GMRSHT36AS47 of 8 models have all five ratings · AHRI 217284813 |
| Non-ducted, 3.5–4.5 tons | 66.5(50 is the typical model of its size class)GMRSHT42AS53 of 5 models qualify · AHRI 217284814 | 67.7(50 is the typical model of its size class)GMRSHT42AS54 of 5 models have all five ratings · AHRI 217284814 |
Newest TGM certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| TSZRHT24ASTGMwith ductless indoor unit TMWHT24S | 2 tons24,000 Btu/h · Non-ducted | 1.80 | 67% | 9.5 | 20.0 | CEE 25CEE 26Xcel | 4 | 218787826 |
| TSZRHT18ASTGMwith ductless indoor unit TMWHT18S | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 67% | 10.0 | 20.0 | None | 4 | 218787825 |
| TSZRHT12ASTGMwith ductless indoor unit TMWHT12S | 1 ton12,000 Btu/h · Non-ducted | 1.80 | 73% | 10.0 | 20.0 | CEE 25CEE 26Xcel | 3 | 218787824 |
| TSZRHT09ASTGMwith ductless indoor unit TMWHT09S | 1 ton9,000 Btu/h · Non-ducted | 1.80 | 80% | 9.5 | 21.0 | CEE 25CEE 26Xcel | 3 | 218787823 |
| TMRHT42AS5TGM | 3.5 tons39,000 Btu/h · Ducted and non-ducted | 2.00 | 71% | 10.0 | 20.0 | CEE 25CEE 26Xcel | 2 | 218787812 |
Compare TGM
TGM includes these brand names as listed in AHRI: TGM. Standards are checked against published thresholds; program rules beyond ratings are not checked.