ROVSUN vs TGM heat pumps
Measured against models of the same size and duct type, TGM scores higher on 4 of the 6 ratings. ROVSUN has 82 outdoor models, TGM has 77 outdoor models. ROVSUN and TGM have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- ROVSUN
- TGM
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | ROVSUN | TGM |
|---|---|---|
| Efficiency index | 44%median — | 45%median — |
| COP at 5°F | 37%median 1.85 | 48%median 1.91 |
| Capacity retention at 5°F | 41%median 73% | 42%median 71% |
| HSPF2 | 52% (higher)median 9.5 | 41% (higher)median 8.6 |
| SEER2 | 51% (higher)median 20.0 | 45% (higher)median 19.0 |
| EER2 | 35%median 11.1 | 42%median 11.2 |
| Heating capacity at 5°F | 46%median 10,750 Btu/h | 47%median 14,100 Btu/h |
| Outdoor models | 82 | 77 |
| AHRI certifications | 91 | 152 |
Share of models meeting each standard
| Standard | ROVSUN | TGM |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 78%64 models | 58.4%45 models |
| CEE 2026 Tier 1 (Split ASHP) | 78%64 models | 57.1%44 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 1.3%1 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 74.4%61 models | 54.5%42 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 1.3%1 models |
| ENERGY STAR Cold Climate | 35.4%29 models | 20.8%16 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- ROVSUN
- TGM
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | ROVSUN | TGM |
|---|---|---|
| Ducted, up to 1.5 tons | 12 · index 54% | 5 · index 62% |
| Ducted, 2 tons | 4 · index 47% | 8 · index 67% |
| Ducted, 2.5–3 tons | 3 · index 45% | 10 · index 50% |
| Ducted, 3.5–4.5 tons | 4 · index 39% | 11 · index 61% |
| Ducted, 5 tons and up | None | 2 · index 69% |
| Non-ducted, up to 1.5 tons | 46 · index 40% | 32 · index 34% |
| Non-ducted, 2 tons | 8 · index 45% | 9 · index 43% |
| Non-ducted, 2.5–3 tons | 6 · index 52% | 8 · index 40% |
| Non-ducted, 3.5–4.5 tons | 1 · index 27% | 5 · index 43% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | ROVSUNCold-climate score, best model | TGMCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 59.0(50 is the typical model of its size class)TD-09D2HRH/DVOAlso listed as TC-09CHRH/DVO-D, TSC-09HA2/I3XI23B-O, RVD-O9D2/O12 of 12 models qualify · AHRI 217154242 | 69.8(50 is the typical model of its size class) (higher)MRS5VHT18ASwith ducted air handler MFC5VHT18S3 of 5 models qualify · AHRI 217274613 |
| Ducted, 2 tons | 68.9(50 is the typical model of its size class)RV-AHU24S-Owith ducted air handler RV-AHU24S-I3 of 4 models qualify · AHRI 218471396 | 77.1(50 is the typical model of its size class) (higher)MRS5VHT24ASwith ducted air handler MFC5VHT24S6 of 8 models qualify · AHRI 217274615 |
| Ducted, 2.5–3 tons | 64.5(50 is the typical model of its size class) (higher)RV-AHU36S-Owith ducted air handler RV-AHU36S-I2 of 3 models qualify · AHRI 218471397 | 63.6(50 is the typical model of its size class)MTVC2OCN036Awith ducted air handler MTA20C036A3 of 10 models qualify · AHRI 218044247 |
| Ducted, 3.5–4.5 tons | 66.4(50 is the typical model of its size class)RV-AHU55S-Owith ducted air handler RV-AHU55S-I4 of 4 models qualify · AHRI 218471398 | 72.2(50 is the typical model of its size class) (higher)OTV18HN048Awith ducted air handler OTA18C006AAlso listed as OTV18HN060A7 of 11 models qualify · AHRI 217747072 |
| Ducted, 5 tons and up | No models in this size class | 64.1(50 is the typical model of its size class)MRB560HWD1 of 2 models qualify · AHRI 217194656 |
| Non-ducted, up to 1.5 tons | 68.6(50 is the typical model of its size class)TMSC-18HA2/I2XI20B-OAlso listed as TMSC-18HA2/I2XI20B-O33 of 46 models qualify · AHRI 216020714 | 79.2(50 is the typical model of its size class) (higher)ARHHBT18ASwith ductless indoor unit AWHHBT18S22 of 32 models qualify · AHRI 218620807 |
| Non-ducted, 2 tons | 62.6(50 is the typical model of its size class)TSC-24HA2/I3XI21B-Owith ductless indoor unit TC-24CHRH/DVIAlso listed as RVC-24/O5 of 8 models qualify · AHRI 217598675 | 77.9(50 is the typical model of its size class) (higher)MRS5VHT24ASwith ductless indoor unit MUV5HT24S6 of 9 models qualify · AHRI 216706039 |
| Non-ducted, 2.5–3 tons | 57.5(50 is the typical model of its size class)TMSC-27HA2/I2XI19B-OAlso listed as TMSC-27HA2/I2XI19B-O6 of 6 models qualify · AHRI 216020715 | 77.2(50 is the typical model of its size class) (higher)GMRSHT36AS46 of 8 models qualify · AHRI 217284813 |
| Non-ducted, 3.5–4.5 tons | 24.7(50 is the typical model of its size class)RV42M2/19-O1 of 1 models qualify · AHRI 218035868 | 66.5(50 is the typical model of its size class) (higher)GMRSHT42AS53 of 5 models qualify · AHRI 217284814 |
All-around best
| Size and duct type | ROVSUNAll-around score, best model | TGMAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 65.2(50 is the typical model of its size class)TD-09D2HRH/DVOAlso listed as TC-09CHRH/DVO-D, TSC-09HA2/I3XI23B-O, RVD-O9D2/O12 of 12 models have all five ratings · AHRI 217154242 | 78.4(50 is the typical model of its size class) (higher)MRS5VHT18ASwith ducted air handler MFC5VHT18S3 of 5 models have all five ratings · AHRI 217274613 |
| Ducted, 2 tons | 70.0(50 is the typical model of its size class)RV-AHU24S-Owith ducted air handler RV-AHU24S-I4 of 4 models have all five ratings · AHRI 218471396 | 79.6(50 is the typical model of its size class) (higher)CTV520HN036Awith ducted air handler CTA520C024A6 of 8 models have all five ratings · AHRI 217138121 |
| Ducted, 2.5–3 tons | 57.9(50 is the typical model of its size class)RV-AHU36S-Owith ducted air handler RV-AHU36S-I3 of 3 models have all five ratings · AHRI 218471397 | 72.8(50 is the typical model of its size class) (higher)MTVC2OCN036Awith ducted air handler MTA20C036A6 of 10 models have all five ratings · AHRI 218044247 |
| Ducted, 3.5–4.5 tons | 54.9(50 is the typical model of its size class)RV-AHU55S-Owith ducted air handler RV-AHU55S-I4 of 4 models have all five ratings · AHRI 218471398 | 72.6(50 is the typical model of its size class) (higher)OTV18HN048Awith ducted air handler OTA18C006AAlso listed as OTV18HN060A8 of 11 models have all five ratings · AHRI 217747072 |
| Ducted, 5 tons and up | No models in this size class | 70.5(50 is the typical model of its size class)MRB560HWD2 of 2 models have all five ratings · AHRI 217194656 |
| Non-ducted, up to 1.5 tons | 72.2(50 is the typical model of its size class)TMSC-18HA2/I2XI20B-OAlso listed as TMSC-18HA2/I2XI20B-O46 of 46 models have all five ratings · AHRI 216020714 | 82.9(50 is the typical model of its size class) (higher)ARHHBT18ASwith ductless indoor unit AWHHBT18S32 of 32 models have all five ratings · AHRI 218620807 |
| Non-ducted, 2 tons | 58.4(50 is the typical model of its size class)TSC-24HA2/I3XI21B-Owith ductless indoor unit TC-24CHRH/DVIAlso listed as RVC-24/O8 of 8 models have all five ratings · AHRI 217598675 | 86.5(50 is the typical model of its size class) (higher)ARHHBT24ASwith ductless indoor unit AWHHBT24S9 of 9 models have all five ratings · AHRI 218620808 |
| Non-ducted, 2.5–3 tons | 65.1(50 is the typical model of its size class) (higher)TMSC-27HA2/I2XI19B-OAlso listed as TMSC-27HA2/I2XI19B-O6 of 6 models have all five ratings · AHRI 216020715 | 64.5(50 is the typical model of its size class)GMRSHT36AS47 of 8 models have all five ratings · AHRI 217284813 |
| Non-ducted, 3.5–4.5 tons | 27.2(50 is the typical model of its size class)RV42M2/19-O1 of 1 models have all five ratings · AHRI 218035868 | 67.7(50 is the typical model of its size class) (higher)GMRSHT42AS54 of 5 models have all five ratings · AHRI 217284814 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | ROVSUN | TGM |
|---|---|---|
| COP at 5°F | beats 77% · 2.10TSC-12HA1/I3XI22B-OAlso listed as TSC-12HA1/I3XI22B-O, RV12T1/22-ONon-ducted, up to 1.5 tons | beats 98% · 2.50ARHCPT18ASNon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 92% · 100%RV-AHU24S-ODucted, 2 tons | beats 88% · 70%MRB560HWDDucted, 5 tons and up |
| HSPF2 | beats 81% · 10.4TSC-24HA2/I3XI21B-OAlso listed as RVC-24/ONon-ducted, 2 tons | beats 94% · 9.7MR5SVHT60ASDucted, 5 tons and up |
| SEER2 | beats 91% · 24.0TMSC-27HA2/I2XI19B-OAlso listed as TMSC-27HA2/I2XI19B-ONon-ducted, 2.5–3 tons | beats 97% · 22.0TMRHT18AS2Ducted, up to 1.5 tons |
| EER2 | beats 70% · 13.0TSC-09HA1/I3XI22B-OAlso listed as TSC-09HA1/I3XI22B-O, TSC-09HA2/I3XI23B-O, RV09T1/22-ONon-ducted, up to 1.5 tons | beats 96% · 14.0ARHHBT24ASNon-ducted, 2 tons |
| Heating capacity at 5°F | beats 91% · 50,000 Btu/hRV-AHU55S-ODucted, 3.5–4.5 tons | beats 86% · 15,000 Btu/hARHHBT18ASNon-ducted, up to 1.5 tons |