ROVSUN vs Samsung heat pumps
Measured against models of the same size and duct type, Samsung scores higher on 6 of the 6 ratings. ROVSUN has 82 outdoor models, Samsung has 82 outdoor models. ROVSUN has no QMID on file and is not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- ROVSUN
- Samsung
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | ROVSUN | Samsung |
|---|---|---|
| Efficiency index | 45%median — | 63%median — · 5th ranked |
| COP at 5°F | 38%median 1.85 | 47%median 2.00 · 21st ranked |
| Capacity retention at 5°F | 43%median 73% | 65%median 79% · 2nd ranked |
| HSPF2 | 53%median 9.5 | 61%median 9.7 · 8th ranked |
| SEER2 | 52%median 20.0 | 63%median 21.2 · 4th ranked |
| EER2 | 37%median 11.1 | 73%median 13.0 · 1st ranked |
| Heating capacity at 5°F | 48%median 10,750 Btu/h | 70%median 17,300 Btu/h · 1st ranked |
| Outdoor models | 82 | 82 |
| AHRI certifications | 91 | 569 |
Share of models meeting each standard
| Standard | ROVSUN | Samsung |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 78%64 models | 95.1%78 models |
| CEE 2026 Tier 1 (Split ASHP) | 78%64 models | 95.1%78 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 9.8%8 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 74.4%61 models | 90.2%74 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 9.8%8 models |
| ENERGY STAR Cold Climate | 35.4%29 models | 70.7%58 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- ROVSUN
- Samsung
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | ROVSUN | Samsung |
|---|---|---|
| Ducted, up to 1.5 tons | 12 · index 55% | 5 · index 55% |
| Ducted, 2 tons | 4 · index 47% | 8 · index 57% |
| Ducted, 2.5 to 3 tons | 3 · index 45% | 11 · index 65% |
| Ducted, 3.5 to 4.5 tons | 4 · index 39% | 9 · index 59% |
| Ducted, 5 tons and up | None | 3 · index 68% |
| Non-ducted, up to 1.5 tons | 46 · index 41% | 41 · index 68% |
| Non-ducted, 2 tons | 8 · index 47% | 15 · index 59% |
| Non-ducted, 2.5 to 3 tons | 6 · index 53% | 10 · index 60% |
| Non-ducted, 3.5 to 4.5 tons | 1 · index 27% | 5 · index 45% |
| Non-ducted, 5 tons and up | None | 3 · index 73% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | ROVSUNCold-climate score, best model | SamsungCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 59.9(50 is the typical model of its size class) (higher)TD-09D2HRH/DVOAlso listed as TC-09CHRH/DVO-D, TSC-09HA2/I3XI23B-O, RVD-O9D2/O12 of 12 models qualify · AHRI 217154242 | 57.2(50 is the typical model of its size class)AC009DXSCCGwith ducted air handler AC009DNHDCG4 of 5 models qualify · AHRI 216441745 |
| Ducted, 2 tons | 68.8(50 is the typical model of its size class) (higher)RV-AHU24S-Owith ducted air handler RV-AHU24S-I3 of 4 models qualify · AHRI 218471396 | 64.5(50 is the typical model of its size class)AC024FCUPCGwith ducted air handler HE**-XX-5-BC**+TXV+RDS+TDR6 of 8 models qualify · AHRI 218405855 |
| Ducted, 2.5 to 3 tons | 64.2(50 is the typical model of its size class)RV-AHU36S-Owith ducted air handler RV-AHU36S-I2 of 3 models qualify · AHRI 218471397 | 80.4(50 is the typical model of its size class) (higher)AC036FCUPCGwith ducted air handler CV362B*A+TXV+AEF48BXP11 of 11 models qualify · AHRI 217993392 |
| Ducted, 3.5 to 4.5 tons | 66.5(50 is the typical model of its size class)RV-AHU55S-Owith ducted air handler RV-AHU55S-I4 of 4 models qualify · AHRI 218471398 | 76.6(50 is the typical model of its size class) (higher)AC048FCUPCGwith ducted air handler L(E,G)M48FJ8 of 9 models qualify · AHRI 218159537 |
| Ducted, 5 tons and up | No models in this size class | 84.3(50 is the typical model of its size class)AM060FCMDCG13 of 3 models qualify · AHRI 216016316 |
| Non-ducted, up to 1.5 tons | 70.1(50 is the typical model of its size class)TMSC-18HA2/I2XI20B-OAlso listed as TMSC-18HA2/I2XI20B-O33 of 46 models qualify · AHRI 216020714 | 92.9(50 is the typical model of its size class) (higher)AR15DXDACWKXwith ductless indoor unit AR15DXDABWKNAlso listed as AR15DXDABWKX35 of 41 models qualify · AHRI 215222778 |
| Non-ducted, 2 tons | 63.9(50 is the typical model of its size class)TSC-24HA2/I3XI21B-Owith ductless indoor unit TC-24CHRH/DVIAlso listed as RVC-24/O5 of 8 models qualify · AHRI 217598675 | 83.8(50 is the typical model of its size class) (higher)AM024HCMDCG13 of 15 models qualify · AHRI 218717190 |
| Non-ducted, 2.5 to 3 tons | 58.2(50 is the typical model of its size class)TMSC-27HA2/I2XI19B-OAlso listed as TMSC-27HA2/I2XI19B-O6 of 6 models qualify · AHRI 216020715 | 82.8(50 is the typical model of its size class) (higher)AM036FCMDCGAlso listed as AM036HCMDCS9 of 10 models qualify · AHRI 216032693 |
| Non-ducted, 3.5 to 4.5 tons | 24.6(50 is the typical model of its size class)RV42M2/19-O1 of 1 models qualify · AHRI 218035868 | 57.5(50 is the typical model of its size class) (higher)AM048FCMDCGAlso listed as AM048HCMDCS3 of 5 models qualify · AHRI 216032694 |
| Non-ducted, 5 tons and up | No models in this size class | 84.1(50 is the typical model of its size class)AM060FCMDCG13 of 3 models qualify · AHRI 216032696 |
All-around best
| Size and duct type | ROVSUNAll-around score, best model | SamsungAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 66.1(50 is the typical model of its size class)TD-09D2HRH/DVOAlso listed as TC-09CHRH/DVO-D, TSC-09HA2/I3XI23B-O, RVD-O9D2/O12 of 12 models have all five ratings · AHRI 217154242 | 72.3(50 is the typical model of its size class) (higher)AC009DXSCCGwith ducted air handler AC009DNLDCG4 of 5 models have all five ratings · AHRI 216441743 |
| Ducted, 2 tons | 70.1(50 is the typical model of its size class)RV-AHU24S-Owith ducted air handler RV-AHU24S-I4 of 4 models have all five ratings · AHRI 218471396 | 79.2(50 is the typical model of its size class) (higher)AJ020DXS3CG7 of 8 models have all five ratings · AHRI 216372803 |
| Ducted, 2.5 to 3 tons | 58.0(50 is the typical model of its size class)RV-AHU36S-Owith ducted air handler RV-AHU36S-I3 of 3 models have all five ratings · AHRI 218471397 | 80.5(50 is the typical model of its size class) (higher)AC030DXSCCGwith ducted air handler AC030DNHDCG11 of 11 models have all five ratings · AHRI 215385456 |
| Ducted, 3.5 to 4.5 tons | 55.3(50 is the typical model of its size class)RV-AHU55S-Owith ducted air handler RV-AHU55S-I4 of 4 models have all five ratings · AHRI 218471398 | 74.3(50 is the typical model of its size class) (higher)AM048FCMDCGAlso listed as AM048HCMDCS9 of 9 models have all five ratings · AHRI 216014183 |
| Ducted, 5 tons and up | No models in this size class | 84.7(50 is the typical model of its size class)AM060FCMDCG13 of 3 models have all five ratings · AHRI 216016316 |
| Non-ducted, up to 1.5 tons | 73.9(50 is the typical model of its size class)TMSC-18HA2/I2XI20B-OAlso listed as TMSC-18HA2/I2XI20B-O46 of 46 models have all five ratings · AHRI 216020714 | 90.4(50 is the typical model of its size class) (higher)AR09DXDACWKXwith ductless indoor unit AR09DXDABWKNAlso listed as AR09DXDABWKX40 of 41 models have all five ratings · AHRI 215399292 |
| Non-ducted, 2 tons | 60.9(50 is the typical model of its size class)TSC-24HA2/I3XI21B-Owith ductless indoor unit TC-24CHRH/DVIAlso listed as RVC-24/O8 of 8 models have all five ratings · AHRI 217598675 | 91.2(50 is the typical model of its size class) (higher)AM024HCMDCG14 of 15 models have all five ratings · AHRI 218717190 |
| Non-ducted, 2.5 to 3 tons | 65.9(50 is the typical model of its size class)TMSC-27HA2/I2XI19B-OAlso listed as TMSC-27HA2/I2XI19B-O6 of 6 models have all five ratings · AHRI 216020715 | 79.2(50 is the typical model of its size class) (higher)AM036FCMDCGAlso listed as AM036HCMDCS9 of 10 models have all five ratings · AHRI 216032693 |
| Non-ducted, 3.5 to 4.5 tons | 26.8(50 is the typical model of its size class)RV42M2/19-O1 of 1 models have all five ratings · AHRI 218035868 | 66.4(50 is the typical model of its size class) (higher)AM048FCMDCGAlso listed as AM048HCMDCS4 of 5 models have all five ratings · AHRI 216032694 |
| Non-ducted, 5 tons and up | No models in this size class | 91.6(50 is the typical model of its size class)AM060FCMDCG13 of 3 models have all five ratings · AHRI 216032696 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | ROVSUN | Samsung |
|---|---|---|
| COP at 5°F | beats 78% · 2.10TSC-12HA1/I3XI22B-OAlso listed as TSC-12HA1/I3XI22B-O, RV12T1/22-ONon-ducted, up to 1.5 tons | beats 98% · 2.50AR15DXDACWKXAlso listed as AR15DXDABWKXNon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 92% · 100%RV-AHU24S-ODucted, 2 tons | beats 99% · 85%AM060FCMDCG1Ducted, 5 tons and up |
| HSPF2 | beats 83% · 10.4TSC-24HA2/I3XI21B-OAlso listed as RVC-24/ONon-ducted, 2 tons | beats 99% · 10.5AM060FCMDCG1Ducted, 5 tons and up |
| SEER2 | beats 90% · 20.3TD-18D2HRH/DVOAlso listed as TSC-18HA2/I3XI21B-O, RVD-18D2/ODucted, up to 1.5 tons | beats 98% · 23.0AM060FCMDCG1Non-ducted, 5 tons and up |
| EER2 | beats 73% · 13.0TSC-09HA1/I3XI22B-OAlso listed as TSC-09HA1/I3XI22B-O, TSC-09HA2/I3XI23B-O, RV09T1/22-ONon-ducted, up to 1.5 tons | beats 100% · 17.0AM024HCMDCGNon-ducted, 2 tons |
| Heating capacity at 5°F | beats 92% · 50,000 Btu/hRV-AHU55S-ODucted, 3.5 to 4.5 tons | beats 100% · 54,000 Btu/hAC024DXSCCGNon-ducted, 2 tons |