AIRDACH heat pump efficiency: 23 outdoor models compared
AIRDACH has 23 heat pump outdoor models certified with this refrigerant group, in 34 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes AIRDACH makes. AIRDACH has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 23
- AHRI certifications
- 34
- Efficiency index
- 57%
- Typical model vs same-size, same-type peers (15 models)
- Meet CEE 2025
- 39.1%
- 9 models
How AIRDACH compares with comparable models
- AIRDACH
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index15 models scored | 57% | Not ranked | — |
| COP at 5°F15 models scored | 47% | Not ranked | 1.91 |
| Capacity retention at 5°F15 models scored | 39% | Not ranked | 67% |
| HSPF227 models scored | 49% | Not ranked | 8.1 |
| SEER227 models scored | 54% | Not ranked | 16.0 |
| EER227 models scored | 58% | Not ranked | 11.7 |
| Heating capacity at 5°F15 models scored | 41% | Not ranked | 14,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 39.1% | 9 |
| CEE 2026 Tier 1 (Split ASHP) | 39.1% | 9 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 21.7% | 5 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- AIRDACH (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 2 | 57% | 22% | 40% | 39% |
| Ducted, 2 tons | 2 | — | — | 39% | 39% |
| Ducted, 2.5–3 tons | 5 | 66% | 38% | 51% | 57% |
| Ducted, 3.5–4.5 tons | 6 | 64% | 10% | 45% | 49% |
| Non-ducted, up to 1.5 tons | 6 | 58% | 68% | 63% | 64% |
| Non-ducted, 2 tons | 1 | 56% | 58% | 50% | 69% |
| Non-ducted, 2.5–3 tons | 4 | 50% | 36% | 41% | 51% |
| Non-ducted, 3.5–4.5 tons | 1 | 52% | 22% | 47% | 61% |
Every AIRDACH model in the market
- AIRDACH models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top AIRDACH models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ACSH1823VM2-DAIRDACHwith ductless indoor unit AIWH1800VM2-D | 1.5 tons18,000 Btu/h · Non-ducted | 70% | 2.38 | 10.3 | 12,600 | 23.7 | CEE 25CEE 26Xcel | 2 | 209948207 | Non-ducted, up to 1.5 tons | 70.6 |
| 2ACSH0924VM2-DAIRDACHwith ductless indoor unit AICH0900VM1-D | 1 ton9,000 Btu/h · Non-ducted | 80% | 1.91 | 10.0 | 8,000 | 20.0 | CEE 25CEE 26Xcel | 2 | 213363365 | Non-ducted, up to 1.5 tons | 63.3 |
| 3AMSH1800VM1-DAIRDACH | 1.5 tons18,000 Btu/h · Non-ducted | 74% | 1.86 | 10.2 | 14,000 | 21.0 | CEE 25CEE 26Xcel | 3 | 210474671 | Non-ducted, up to 1.5 tons | 57.1 |
| 4AMSH2700VM1-DAIRDACH | 2.5 tons27,000 Btu/h · Non-ducted | 71% | 1.83 | 9.2 | 20,000 | 23.5 | CEE 25CEE 26Xcel | 3 | 210474674 | Non-ducted, 2.5–3 tons | 50.1 |
| 5AMSH1800VM1-DAIRDACH | 1.5 tons18,000 Btu/h · Ducted | 74% | 1.86 | 9.8 | 14,000 | 19.0 | CEE 25CEE 26Xcel | 3 | 210474672 | Ducted, up to 1.5 tons | 46.5 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ACSH1823VM2-DAIRDACHwith ductless indoor unit AIWH1800VM2-D | 1.5 tons18,000 Btu/h · Non-ducted | 70% | 2.38 | 10.3 | 23.7 | 13.5 | CEE 25CEE 26Xcel | 2 | 209948207 | Non-ducted, up to 1.5 tons | 75.9 | 70.6 | 81.2 | 70.6 |
| 2ACSH0924VM2-DAIRDACHwith ductless indoor unit AIWH0900VM2-D | 1 ton9,000 Btu/h · Non-ducted | 65% | 2.11 | 11.4 | 24.0 | 14.0 | CEE 25CEE 26Xcel | 2 | 209948205 | Non-ducted, up to 1.5 tons | 75.6 | 65.4 | 85.7 | 63.3 |
| 3AMSH2700VM1-DAIRDACH | 2.5 tons28,000 Btu/h · Ducted | 67% | 2.00 | 9.2 | 21.0 | 11.7 | CEE 25CEE 26 | 3 | 210474675 | Ducted, 2.5–3 tons | 75.5 | 65.4 | 85.6 | Not a pick |
| 4ACSH1222VM2-DAIRDACHwith ductless indoor unit AICH1200VM1-D | 1 ton12,000 Btu/h · Non-ducted | 67% | 2.27 | 10.0 | 22.7 | 14.0 | CEE 25CEE 26 | 2 | 210476736 | Non-ducted, up to 1.5 tons | 71.8 | 64.3 | 79.3 | Not a pick |
| 5AMSH2700VM1-DAIRDACH | 2.5 tons27,000 Btu/h · Non-ducted | 71% | 1.83 | 9.2 | 23.5 | 12.2 | CEE 25CEE 26Xcel | 3 | 210474674 | Non-ducted, 2.5–3 tons | 67.1 | 50.1 | 84.1 | 50.1 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | ACSH1823VM2-D | 2.38 | Non-ducted, up to 1.5 tons | 96% | 209948207 |
| Capacity retention at 5°F | ACSH0924VM2-D | 80% | Non-ducted, up to 1.5 tons | 67% | 213363365 |
| HSPF2 | AMSH4800VM1-D | 9.7 | Ducted, 3.5–4.5 tons | 95% | 210474681 |
| SEER2 | AMSH2700VM1-D | 21.0 | Ducted, 2.5–3 tons | 98% | 210474675 |
| EER2 | ACSH0924VM2-D | 14.0 | Non-ducted, up to 1.5 tons | 85% | 209948205 |
| Heating capacity at 5°F | AMSH1800VM1-D | 14,000 Btu/h | Non-ducted, up to 1.5 tons | 85% | 210474671 |
AIRDACH size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 46.5(50 is the typical model of its size class)AMSH1800VM1-D1 of 2 models qualify · AHRI 210474672 | 56.7(50 is the typical model of its size class)AMSH1800VM1-D1 of 2 models have all five ratings · AHRI 210474672 |
| Ducted, 2 tons | None on this board (0 of 2 models qualify) | None on this board (0 of 2 models have all five ratings) |
| Ducted, 2.5–3 tons | None on this board (0 of 5 models qualify) | 75.5(50 is the typical model of its size class)AMSH2700VM1-D2 of 5 models have all five ratings · AHRI 210474675 |
| Ducted, 3.5–4.5 tons | None on this board (0 of 6 models qualify) | 63.5(50 is the typical model of its size class)AMSH4800VM1-D1 of 6 models have all five ratings · AHRI 210474681 |
| Non-ducted, up to 1.5 tons | 70.6(50 is the typical model of its size class)ACSH1823VM2-Dwith ductless indoor unit AIWH1800VM2-D3 of 6 models qualify · AHRI 209948207 | 75.9(50 is the typical model of its size class)ACSH1823VM2-Dwith ductless indoor unit AIWH1800VM2-D6 of 6 models have all five ratings · AHRI 209948207 |
| Non-ducted, 2 tons | None on this board (0 of 1 models qualify) | 56.2(50 is the typical model of its size class)ACSH2421VM2-Dwith ductless indoor unit AIWH2400VM2-D1 of 1 models have all five ratings · AHRI 209948204 |
| Non-ducted, 2.5–3 tons | 50.1(50 is the typical model of its size class)AMSH2700VM1-D1 of 4 models qualify · AHRI 210474674 | 67.1(50 is the typical model of its size class)AMSH2700VM1-D3 of 4 models have all five ratings · AHRI 210474674 |
| Non-ducted, 3.5–4.5 tons | 39.4(50 is the typical model of its size class)AMSH4800VM1-D1 of 1 models qualify · AHRI 210474680 | 51.7(50 is the typical model of its size class)AMSH4800VM1-D1 of 1 models have all five ratings · AHRI 210474680 |
Newest AIRDACH certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| ACSH0924VM2-DAIRDACHwith ductless indoor unit AICH0900VM1-D | 1 ton9,000 Btu/h · Non-ducted | 1.91 | 80% | 10.0 | 20.0 | CEE 25CEE 26Xcel | 2 | 213363365 |
| ACTH6015NG2-DAIRDACHwith ducted air handler AIDC6000NG3-D | 4 tons50,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | None | 1 | 212437205 |
| ACTH4815NG2-DAIRDACHwith ducted air handler AIDC4800NG3-D | 4 tons47,500 Btu/h · Ducted | — | — | 7.5 | 14.3 | None | 1 | 212437204 |
| ACTH4215NG2-DAIRDACHwith ducted air handler AIDC4200NG3-D | 3.5 tons40,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | None | 1 | 212437203 |
| ACTH3615NG2-DAIRDACHwith ducted air handler AIDC3600NG3-D | 3 tons33,000 Btu/h · Ducted | — | — | 7.7 | 14.3 | None | 1 | 212437202 |
Compare AIRDACH
AIRDACH includes these brand names as listed in AHRI: AIRDACH. Standards are checked against published thresholds; program rules beyond ratings are not checked.