- Insights
- Manufacturers
- Airdach
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Airdach heat pump efficiency: 29 outdoor models compared
Airdach has 29 heat pump outdoor models certified with this refrigerant group, in 45 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Airdach makes. Airdach has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 29
- AHRI certifications
- 45
- Efficiency index
- 40%
- Typical model vs same-size, same-type peers (15 models)
- Meet CEE 2025
- 24.1%
- 7 models
How Airdach compares with comparable models
- Airdach
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index15 models scored | 40% | Not ranked | — |
| COP at 5°F15 models scored | 48% | Not ranked | 1.94 |
| Capacity retention at 5°F15 models scored | 34% | Not ranked | 71% |
| HSPF229 models scored | 28% | Not ranked | 7.5 |
| SEER229 models scored | 29% | Not ranked | 14.3 |
| EER229 models scored | 49% | Not ranked | 11.4 |
| Heating capacity at 5°F15 models scored | 31% | Not ranked | 15,700 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 24.1% | 7 |
| CEE 2026 Tier 1 (Split ASHP) | 24.1% | 7 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 31% | 9 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- Airdach (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 2 | — | — | 14% | 22% |
| Ducted, 2 tons | 3 | 36% | 41% | 24% | 17% |
| Ducted, 2.5–3 tons | 7 | 48% | 60% | 35% | 29% |
| Ducted, 3.5–4.5 tons | 10 | 54% | 84% | 36% | 32% |
| Non-ducted, up to 1.5 tons | 5 | 30% | 31% | 16% | 30% |
| Non-ducted, 2 tons | 1 | 25% | 2% | 12% | 26% |
| Non-ducted, 2.5–3 tons | 1 | 30% | 7% | 12% | 49% |
Every Airdach model in the market
- Airdach models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top Airdach models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1A3TH60180OV1DGAirdachwith ducted air handler A3DH60000OE1DT | 4.5 tons55,000 Btu/h · Ducted | 73% | 2.30 | 8.8 | 40,000 | 18.0 | CEE 25CEE 26Xcel | 1 | 218797046 | Ducted, 3.5–4.5 tons | 69.8 |
| 2A3TH36180OV1DGAirdachwith ducted air handler A3DH36000OE1DT | 3 tons33,000 Btu/h · Ducted | 73% | 2.00 | 8.8 | 24,000 | 18.0 | CEE 25CEE 26Xcel | 1 | 218797045 | Ducted, 2.5–3 tons | 59.2 |
| 3ACSH0920VR1-D3Airdachwith ductless indoor unit AIWH0900VR1-D3 | 1 ton9,100 Btu/h · Non-ducted | 76% | 1.94 | 8.8 | 7,600 | 20.5 | CEE 25CEE 26Xcel | 1 | 217101992 | Non-ducted, up to 1.5 tons | 41.6 |
| 4ACSH0920VR1-A3Airdachwith ductless indoor unit AIWH0900VR1-A3 | 1 ton9,100 Btu/h · Non-ducted | 76% | 1.86 | 8.8 | 7,600 | 20.5 | CEE 25CEE 26Xcel | 1 | 217101995 | Non-ducted, up to 1.5 tons | 37.3 |
| 5ACSH1219VR1-D3Airdachwith ductless indoor unit AIWH1200VR1-D3 | 1 ton12,000 Btu/h · Non-ducted | 76% | 1.80 | 8.5 | 9,100 | 19.0 | Xcel | 1 | 217101994 | Non-ducted, up to 1.5 tons | 26.7 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1A3TH60180OV1DGAirdachwith ducted air handler A3DH60000OE1DT | 4.5 tons55,000 Btu/h · Ducted | 73% | 2.30 | 8.8 | 18.0 | 10.0 | CEE 25CEE 26Xcel | 1 | 218797046 | Ducted, 3.5–4.5 tons | 59.5 | 69.8 | 49.3 | 69.8 |
| 2A3TH36180OV1DGAirdachwith ducted air handler A3DH36000OE1DT | 3 tons33,000 Btu/h · Ducted | 73% | 2.00 | 8.8 | 18.0 | 11.2 | CEE 25CEE 26Xcel | 1 | 218797045 | Ducted, 2.5–3 tons | 57.4 | 59.2 | 55.7 | 59.2 |
| 3A4TH42152MN1DLAIRDACHwith ducted air handler A4DH4800ME1DT | 3.5 tons41,500 Btu/h · Ducted | 50% | 2.30 | 7.8 | 15.2 | 12.0 | None | 1 | 218331778 | Ducted, 3.5–4.5 tons | 57.1 | 50.1 | 64.2 | Not a pick |
| 4A4TH48152MN1DLAIRDACHwith ducted air handler A4DH4800ME1DT | 4 tons45,000 Btu/h · Ducted | 49% | 2.28 | 7.8 | 14.8 | 12.0 | None | 1 | 218331776 | Ducted, 3.5–4.5 tons | 54.8 | 49.0 | 60.5 | Not a pick |
| 5ACSH0920VR1-D3Airdachwith ductless indoor unit AIWH0900VR1-D3 | 1 ton9,100 Btu/h · Non-ducted | 76% | 1.94 | 8.8 | 20.5 | 12.5 | CEE 25CEE 26Xcel | 1 | 217101992 | Non-ducted, up to 1.5 tons | 44.9 | 41.6 | 48.3 | 41.6 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | A4TH42152MN1DL | 2.30 | Ducted, 3.5–4.5 tons | 86% | 218331778 |
| Capacity retention at 5°F | A3TH36180OV1DG | 73% | Ducted, 2.5–3 tons | 55% | 218797045 |
| HSPF2 | A3TH60180OV1DG | 8.8 | Ducted, 3.5–4.5 tons | 64% | 218797046 |
| SEER2 | A3TH60180OV1DG | 18.0 | Ducted, 3.5–4.5 tons | 76% | 218797046 |
| EER2 | A4TH48152MN1DL | 12.0 | Ducted, 3.5–4.5 tons | 83% | 218331776 |
| Heating capacity at 5°F | ACSH1820VR1-D3 | 12,100 Btu/h | Non-ducted, up to 1.5 tons | 69% | 217101993 |
Airdach size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 2 models qualify) | None on this board (0 of 2 models have all five ratings) |
| Ducted, 2 tons | None on this board (0 of 3 models qualify) | 35.7(50 is the typical model of its size class)A4TH24152MN1DLwith ducted air handler A4DH2400ME1DT1 of 3 models have all five ratings · AHRI 218331772 |
| Ducted, 2.5–3 tons | 59.2(50 is the typical model of its size class)A3TH36180OV1DGwith ducted air handler A3DH36000OE1DT1 of 7 models qualify · AHRI 218797045 | 57.4(50 is the typical model of its size class)A3TH36180OV1DGwith ducted air handler A3DH36000OE1DT3 of 7 models have all five ratings · AHRI 218797045 |
| Ducted, 3.5–4.5 tons | 69.8(50 is the typical model of its size class)A3TH60180OV1DGwith ducted air handler A3DH60000OE1DT1 of 10 models qualify · AHRI 218797046 | 59.5(50 is the typical model of its size class)A3TH60180OV1DGwith ducted air handler A3DH60000OE1DT4 of 10 models have all five ratings · AHRI 218797046 |
| Non-ducted, up to 1.5 tons | 41.6(50 is the typical model of its size class)ACSH0920VR1-D3with ductless indoor unit AIWH0900VR1-D35 of 5 models qualify · AHRI 217101992 | 44.9(50 is the typical model of its size class)ACSH0920VR1-D3with ductless indoor unit AIWH0900VR1-D35 of 5 models have all five ratings · AHRI 217101992 |
| Non-ducted, 2 tons | 13.5(50 is the typical model of its size class)ACSH2419VR1-D3with ductless indoor unit AIWH2400VR1-D31 of 1 models qualify · AHRI 217101991 | 24.5(50 is the typical model of its size class)ACSH2419VR1-D3with ductless indoor unit AIWH2400VR1-D31 of 1 models have all five ratings · AHRI 217101991 |
| Non-ducted, 2.5–3 tons | 22.3(50 is the typical model of its size class)ACSH3621VR1-D3with ductless indoor unit AIWH3600VR1-D31 of 1 models qualify · AHRI 217101990 | 30.4(50 is the typical model of its size class)ACSH3621VR1-D3with ductless indoor unit AIWH3600VR1-D31 of 1 models have all five ratings · AHRI 217101990 |
Newest Airdach certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| A3TH60152ON1DGAirdachwith ducted air handler A3DH60000OE1DT | 4.5 tons55,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | None | 2 | 218799876 |
| A3TH48152ON1DGAirdachwith ducted air handler A3DH60000OE1DT | 4 tons45,000 Btu/h · Ducted | — | — | 7.6 | 15.0 | None | 2 | 218799875 |
| A3TH42152ON1DGAirdachwith ducted air handler A3DH36000OE1DT | 3.5 tons40,000 Btu/h · Ducted | — | — | 7.6 | 15.2 | None | 2 | 218799874 |
| A3TH36152ON1DGAirdachwith ducted air handler A3DH36000OE1DT | 3 tons33,000 Btu/h · Ducted | — | — | 7.6 | 15.2 | None | 3 | 218799873 |
| A3TH30152ON1DGAirdachwith ducted air handler A3DH36000OE1DT | 2.5 tons28,000 Btu/h · Ducted | — | — | 7.6 | 15.2 | None | 3 | 218799872 |
Compare Airdach
Airdach includes these brand names as listed in AHRI: Airdach. Standards are checked against published thresholds; program rules beyond ratings are not checked.