Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
CIAC heat pump efficiency: 21 outdoor models compared
CIAC has 21 heat pump outdoor models certified with this refrigerant group, in 38 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes CIAC makes. CIAC has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 21
- AHRI certifications
- 38
- Efficiency index
- 50%
- Typical model vs same-size, same-type peers (25 models)
- Meet CEE 2025
- 47.6%
- 10 models
How CIAC compares with comparable models
- CIAC
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index25 models scored | 50% | Not ranked | — |
| COP at 5°F25 models scored | 64% | Not ranked | 1.96 |
| Capacity retention at 5°F25 models scored | 37% | Not ranked | 63% |
| HSPF231 models scored | 54% | Not ranked | 8.8 |
| SEER231 models scored | 45% | Not ranked | 19.0 |
| EER231 models scored | 39% | Not ranked | 10.3 |
| Heating capacity at 5°F25 models scored | 40% | Not ranked | 18,200 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 47.6% | 10 |
| CEE 2026 Tier 1 (Split ASHP) | 42.9% | 9 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 23.8% | 5 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- CIAC (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 3 | 72% | 79% | 87% | 79% |
| Ducted, 2 tons | 1 | 85% | 80% | 98% | 85% |
| Ducted, 2.5–3 tons | 2 | 38% | 54% | 64% | 39% |
| Ducted, 3.5–4.5 tons | 2 | 44% | 49% | 81% | 38% |
| Ducted, 5 tons and up | 2 | 57% | 62% | 70% | 73% |
| Non-ducted, up to 1.5 tons | 7 | 49% | 62% | 54% | 47% |
| Non-ducted, 2 tons | 2 | 50% | 64% | 61% | 51% |
| Non-ducted, 2.5–3 tons | 8 | 39% | 59% | 30% | 32% |
| Non-ducted, 3.5–4.5 tons | 4 | 39% | 66% | 37% | 25% |
Every CIAC model in the market
- CIAC models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top CIAC models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1CM43BX024-H3N2HCIACwith ducted air handler CC43BX024-E3N1H | 2 tons23,000 Btu/h · Ducted | 81% | 2.30 | 11.2 | 20,000 | 19.0 | CEE 25CEE 26Xcel | 3 | 213927687 | Ducted, 2 tons | 82.4 |
| 2CM43BX024-H3N2HCIACwith ductless indoor unit CF43BX024-M3N1H | 2 tons24,000 Btu/h · Non-ducted | 76% | 2.20 | 10.3 | 18,200 | 21.2 | CEE 25CEE 26Xcel | 3 | 213927680 | Non-ducted, 2 tons | 74.2 |
| 3CM43BX009-H3N2HCIACwith ducted air handler CC43BX009-E3N1H | 1 ton9,000 Btu/h · Ducted | 80% | 2.09 | 10.2 | 8,000 | 19.2 | CEE 25CEE 26Xcel | 2 | 213927684 | Ducted, up to 1.5 tons | 70.4 |
| 4CM43BX012-H3N2HCIACwith ducted air handler CC43BX012-E3N1H | 1 ton11,500 Btu/h · Ducted | 70% | 2.26 | 10.3 | 8,400 | 19.0 | CEE 25CEE 26Xcel | 2 | 213927685 | Ducted, up to 1.5 tons | 67.8 |
| 5CM43BX009-H3N2HCIACwith ductless indoor unit CK43BX009-C3N1H | 1 ton9,000 Btu/h · Non-ducted | 80% | 1.91 | 10.0 | 8,000 | 20.0 | CEE 25CEE 26Xcel | 2 | 213927673 | Non-ducted, up to 1.5 tons | 63.3 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1CM43BX024-H3N2HCIACwith ducted air handler CC43BX024-E3N1H | 2 tons23,000 Btu/h · Ducted | 81% | 2.30 | 11.2 | 19.0 | 12.5 | CEE 25CEE 26Xcel | 3 | 213927687 | Ducted, 2 tons | 84.9 | 82.4 | 87.4 | 82.4 |
| 2CM43BX018-H3N2HCIACwith ducted air handler CC43BX018-E3N1H | 1.5 tons17,000 Btu/h · Ducted | 65% | 2.40 | 10.6 | 20.0 | 12.5 | CEE 25CEE 26 | 3 | 213927686 | Ducted, up to 1.5 tons | 78.5 | 68.7 | 88.2 | Not a pick |
| 3CM43BX009-H3N2HCIACwith ducted air handler CC43BX009-E3N1H | 1 ton9,000 Btu/h · Ducted | 80% | 2.09 | 10.2 | 19.2 | 12.5 | CEE 25CEE 26Xcel | 2 | 213927684 | Ducted, up to 1.5 tons | 76.5 | 70.4 | 82.7 | 70.4 |
| 4CM43BX024-H3N2HCIACwith ductless indoor unit CF43BX024-M3N1H | 2 tons24,000 Btu/h · Non-ducted | 76% | 2.20 | 10.3 | 21.2 | 12.5 | CEE 25CEE 26Xcel | 3 | 213927680 | Non-ducted, 2 tons | 72.0 | 74.2 | 69.8 | 74.2 |
| 5CM43BX012-H3N2HCIACwith ductless indoor unit CK43BX012-C3N1H | 1 ton12,000 Btu/h · Non-ducted | 67% | 2.28 | 10.0 | 22.7 | 14.0 | CEE 25CEE 26 | 2 | 213927674 | Non-ducted, up to 1.5 tons | 71.9 | 64.5 | 79.3 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | CM43BX012-H3N2H | 2.28 | Non-ducted, up to 1.5 tons | 92% | 213927674 |
| Capacity retention at 5°F | CM43BX060-H3N1H | 59% | Ducted, 5 tons and up | 73% | 205778936 |
| HSPF2 | CM43BX024-H3N2H | 11.2 | Ducted, 2 tons | 98% | 213927687 |
| SEER2 | CM43BX018-H3N2H | 20.0 | Ducted, up to 1.5 tons | 89% | 213927686 |
| EER2 | CM43BX024-H3N2H | 12.5 | Ducted, 2 tons | 85% | 213927687 |
| Heating capacity at 5°F | CM43BX018-H3N2H | 13,000 Btu/h | Non-ducted, up to 1.5 tons | 78% | 213927679 |
CIAC size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 70.4(50 is the typical model of its size class)CM43BX009-H3N2Hwith ducted air handler CC43BX009-E3N1H2 of 3 models qualify · AHRI 213927684 | 78.5(50 is the typical model of its size class)CM43BX018-H3N2Hwith ducted air handler CC43BX018-E3N1H3 of 3 models have all five ratings · AHRI 213927686 |
| Ducted, 2 tons | 82.4(50 is the typical model of its size class)CM43BX024-H3N2Hwith ducted air handler CC43BX024-E3N1H1 of 1 models qualify · AHRI 213927687 | 84.9(50 is the typical model of its size class)CM43BX024-H3N2Hwith ducted air handler CC43BX024-E3N1H1 of 1 models have all five ratings · AHRI 213927687 |
| Ducted, 2.5–3 tons | None on this board (0 of 2 models qualify) | 37.6(50 is the typical model of its size class)CM43BX036-H3N2Hwith ducted air handler CC43BX036-E3N1H1 of 2 models have all five ratings · AHRI 213927688 |
| Ducted, 3.5–4.5 tons | None on this board (0 of 2 models qualify) | 43.5(50 is the typical model of its size class)CM43BX048-H3N2Hwith ducted air handler CC43BX048-E3N1H1 of 2 models have all five ratings · AHRI 213927689 |
| Ducted, 5 tons and up | None on this board (0 of 2 models qualify) | 58.8(50 is the typical model of its size class)CM43BX060-H3N2Hwith ducted air handler CC43BX060-E3N1H2 of 2 models have all five ratings · AHRI 213927690 |
| Non-ducted, up to 1.5 tons | 63.3(50 is the typical model of its size class)CM43BX009-H3N2Hwith ductless indoor unit CK43BX009-C3N1H1 of 7 models qualify · AHRI 213927673 | 71.9(50 is the typical model of its size class)CM43BX012-H3N2Hwith ductless indoor unit CK43BX012-C3N1H7 of 7 models have all five ratings · AHRI 213927674 |
| Non-ducted, 2 tons | 74.2(50 is the typical model of its size class)CM43BX024-H3N2Hwith ductless indoor unit CF43BX024-M3N1H1 of 2 models qualify · AHRI 213927680 | 72.0(50 is the typical model of its size class)CM43BX024-H3N2Hwith ductless indoor unit CF43BX024-M3N1H2 of 2 models have all five ratings · AHRI 213927680 |
| Non-ducted, 2.5–3 tons | 44.1(50 is the typical model of its size class)CG43MX036PH3H1Cwith ductless indoor unit CH43MX036-H3H1C1 of 8 models qualify · AHRI 212925551 | 53.1(50 is the typical model of its size class)CG43WX030PH3N1Hwith ductless indoor unit CH43WX030-H3N1H6 of 8 models have all five ratings · AHRI 209948220 |
| Non-ducted, 3.5–4.5 tons | 56.4(50 is the typical model of its size class)CM43BX048-H3N2Hwith ductless indoor unit CF43BX048-M3N1H1 of 4 models qualify · AHRI 213927682 | 40.6(50 is the typical model of its size class)CM43BX048-H3N2Hwith ductless indoor unit CF43BX048-M3N1H2 of 4 models have all five ratings · AHRI 213927682 |
Newest CIAC certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| CG420B-X012PH1N1HCIACwith ductless indoor unit CH420B-X012-H1N1H | 1 ton12,000 Btu/h · Non-ducted | 1.78 | 53% | 8.7 | 20.8 | None | 1 | 214521882 |
| CG420B-X012PH3N1HCIACwith ductless indoor unit CH420B-X012-H3N1H | 1 ton12,000 Btu/h · Non-ducted | 1.81 | 66% | 9.2 | 21.4 | CEE 25CEE 26 | 1 | 214521881 |
| CG420B-X024PH3N1HCIACwith ductless indoor unit CH420B-X024-H3N1H | 2 tons24,000 Btu/h · Non-ducted | 1.83 | 62% | 8.6 | 18.5 | None | 1 | 214521880 |
| CG420B-X009PH3N1HCIACwith ductless indoor unit CH420B-X009-H3N1H | 1 ton9,000 Btu/h · Non-ducted | 2.14 | 69% | 9.4 | 21.7 | CEE 25CEE 26 | 1 | 214521879 |
| CG420B-X018PH3N1HCIACwith ductless indoor unit CH420B-X018-H3N1H | 1.5 tons18,000 Btu/h · Non-ducted | 2.18 | 64% | 8.7 | 19.5 | CEE 25CEE 26 | 1 | 214521878 |
Compare CIAC