- Insights
- Manufacturers
- Coast Air
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Coast Air heat pump efficiency: 6 outdoor models compared
Coast Air has 6 heat pump outdoor models certified with this refrigerant group, in 6 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Coast Air makes. Coast Air has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 6
- AHRI certifications
- 6
- Efficiency index
- 50%
- Typical model vs same-size, same-type peers (5 models)
- Meet CEE 2025
- 66.7%
- 4 models
How Coast Air compares with comparable models
- Coast Air
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index5 models scored | 50% | Not ranked | — |
| COP at 5°F5 models scored | 52% | Not ranked | 1.95 |
| Capacity retention at 5°F5 models scored | 16% | Not ranked | 63% |
| HSPF26 models scored | 46% | Not ranked | 9.1 |
| SEER26 models scored | 54% | Not ranked | 21.5 |
| EER26 models scored | 48% | Not ranked | 12.5 |
| Heating capacity at 5°F5 models scored | 26% | Not ranked | 11,700 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 66.7% | 4 |
| CEE 2026 Tier 1 (Split ASHP) | 66.7% | 4 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0% | 0 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- Coast Air (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Non-ducted, up to 1.5 tons | 3 | 60% | 62% | 64% | 77% |
| Non-ducted, 2 tons | 1 | 51% | 43% | 58% | 58% |
| Non-ducted, 2.5–3 tons | 2 | 21% | 31% | 15% | 17% |
Every Coast Air model in the market
- Coast Air models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top Coast Air models
Cold-climate picks
No Coast Air model keeps at least 70% of its heat at 5°F with all three cold-climate ratings.
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1A-CAD09-0ACoast Air · A-serieswith ductless indoor unit B-CAD09-0A | 1 ton9,000 Btu/h · Non-ducted | 65% | 1.96 | 10.8 | 25.0 | 14.5 | CEE 25CEE 26 | 1 | 214312526 | Non-ducted, up to 1.5 tons | 72.3 | 55.6 | 89.0 | Not a pick |
| 2A-CAD18-1ACoast Air · A-serieswith ductless indoor unit B-CAD18-1A | 1.5 tons18,000 Btu/h · Non-ducted | 65% | 2.05 | 9.8 | 22.7 | 12.6 | CEE 25CEE 26 | 1 | 211126491 | Non-ducted, up to 1.5 tons | 59.1 | 52.0 | 66.3 | Not a pick |
| 3A-CAD24-1ACoast Air · A-serieswith ductless indoor unit B-CAD24-1A | 2 tons23,000 Btu/h · Non-ducted | 63% | 1.83 | 9.2 | 20.5 | 12.5 | CEE 25CEE 26 | 1 | 211126489 | Non-ducted, 2 tons | 51.4 | 41.2 | 61.7 | Not a pick |
| 4A-CAD12-0ACoast Air · A-serieswith ductless indoor unit B-CAD12-0A | 1 ton12,000 Btu/h · Non-ducted | 53% | 1.95 | 9.0 | 22.5 | 12.5 | CEE 25CEE 26 | 1 | 211126490 | Non-ducted, up to 1.5 tons | 47.2 | 34.9 | 59.6 | Not a pick |
| 5A-CAD36-1ACoast Airwith ductless indoor unit B-CAD36-1A | 3 tons36,000 Btu/h · Non-ducted | 57% | 1.82 | 8.0 | 18.3 | 8.7 | None | 1 | 211126488 | Non-ducted, 2.5–3 tons | 20.9 | 18.5 | 23.2 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | A-CAD18-1A | 2.05 | Non-ducted, up to 1.5 tons | 70% | 211126491 |
| Capacity retention at 5°F | A-CAD24-1A | 63% | Non-ducted, 2 tons | 23% | 211126489 |
| HSPF2 | A-CAD09-0A | 10.8 | Non-ducted, up to 1.5 tons | 85% | 214312526 |
| SEER2 | A-CAD09-0A | 25.0 | Non-ducted, up to 1.5 tons | 87% | 214312526 |
| EER2 | A-CAD09-0A | 14.5 | Non-ducted, up to 1.5 tons | 89% | 214312526 |
| Heating capacity at 5°F | A-CAD18-1A | 11,700 Btu/h | Non-ducted, up to 1.5 tons | 63% | 211126491 |
Coast Air size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | None on this board (0 of 3 models qualify) | 72.3(50 is the typical model of its size class)A-CAD09-0Awith ductless indoor unit B-CAD09-0A3 of 3 models have all five ratings · AHRI 214312526 |
| Non-ducted, 2 tons | None on this board (0 of 1 models qualify) | 51.4(50 is the typical model of its size class)A-CAD24-1Awith ductless indoor unit B-CAD24-1A1 of 1 models have all five ratings · AHRI 211126489 |
| Non-ducted, 2.5–3 tons | None on this board (0 of 2 models qualify) | 20.9(50 is the typical model of its size class)A-CAD36-1Awith ductless indoor unit B-CAD36-1A1 of 2 models have all five ratings · AHRI 211126488 |
Newest Coast Air certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| A-CAD09-0ACoast Air · A-serieswith ductless indoor unit B-CAD09-0A | 1 ton9,000 Btu/h · Non-ducted | 1.96 | 65% | 10.8 | 25.0 | CEE 25CEE 26 | 1 | 214312526 |
| A-CAD18-1ACoast Air · A-serieswith ductless indoor unit B-CAD18-1A | 1.5 tons18,000 Btu/h · Non-ducted | 2.05 | 65% | 9.8 | 22.7 | CEE 25CEE 26 | 1 | 211126491 |
| A-CAD12-0ACoast Air · A-serieswith ductless indoor unit B-CAD12-0A | 1 ton12,000 Btu/h · Non-ducted | 1.95 | 53% | 9.0 | 22.5 | CEE 25CEE 26 | 1 | 211126490 |
| A-CAD24-1ACoast Air · A-serieswith ductless indoor unit B-CAD24-1A | 2 tons23,000 Btu/h · Non-ducted | 1.83 | 63% | 9.2 | 20.5 | CEE 25CEE 26 | 1 | 211126489 |
| A-CAD36-1ACoast Airwith ductless indoor unit B-CAD36-1A | 3 tons36,000 Btu/h · Non-ducted | 1.82 | 57% | 8.0 | 18.3 | None | 1 | 211126488 |
Compare Coast Air
Coast Air includes these brand names as listed in AHRI: Coast Air. Standards are checked against published thresholds; program rules beyond ratings are not checked.