Skip to content

Coast Air heat pump efficiency: 4 outdoor models compared

Coast Air has 4 heat pump outdoor models certified with this refrigerant group, in 4 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Coast Air makes. Coast Air has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
4
AHRI certifications
4
Efficiency index
67%
Typical model vs same-size, same-type peers (4 models)
Meet CEE 2025
100%
4 models

How Coast Air compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
Coast Air against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of Coast Air’s own modelsCoast Air is strongest on COP at 5°F (its typical model beats 76% of comparable models) and weakest on capacity retention at 5°F (29%).
  • Coast Air
  • Middle half of its models
  • Other ranked manufacturers
Coast Air

Source: AHRI Directory, NEEP · as of

Average peer percentile of Coast Air’s models
RatingBeats comparable modelsRankRaw median
Efficiency index4 models scored67%Not ranked—
COP at 5°F4 models scored76%Not ranked2.13
Capacity retention at 5°F4 models scored29%Not ranked71%
HSPF24 models scored75%Not ranked10.9
SEER24 models scored72%Not ranked23.1
EER24 models scored75%Not ranked13.2
Heating capacity at 5°F4 models scored37%Not ranked10,600 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
Coast Air’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • Coast Air (median, middle 50%, 10th–90th)
  • All models of the group
Non-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Non-ducted, up to 1.5 tons370%84%86%72%
Non-ducted, 2 tons156%51%44%75%

Every Coast Air model in the market

Coast Air’s 4 models with a known size and duct type, over the shape of the whole catalog.
Coast Air models by size and ratingColoured: Coast Air · grey shapes: all 14,508 models · lines: catalog medians by size
  • Coast Air models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 4 coast air models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 14,508 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8261.641.711.751.852.24
Ducted, 1 ton4071.801.902.052.412.45
Ducted, 1.5 tons9921.751.862.002.172.40
Ducted, 2 tons9991.751.862.002.182.30
Ducted, 2.5 tons1,0401.701.802.002.102.36
Ducted, 3 tons6961.801.902.002.102.42
Ducted, 3.5 tons8641.701.802.002.102.46
Ducted, 4 tons7271.801.862.002.122.40
Ducted, 4.5 tons6901.701.801.902.102.20
Ducted, 5 tons861.892.002.102.102.10
Non-ducted, 0.5 tons1,1861.751.801.902.002.22
Non-ducted, 1 ton1,3431.801.801.992.102.21
Non-ducted, 1.5 tons1,2611.801.802.002.102.31
Non-ducted, 2 tons7611.801.982.002.102.30
Non-ducted, 2.5 tons4031.801.852.002.002.10
Non-ducted, 3 tons4731.901.982.002.032.20
Non-ducted, 3.5 tons2802.002.002.002.052.10
Non-ducted, 4 tons2041.962.002.052.102.11
Non-ducted, 4.5 tons781.901.911.952.012.01
Non-ducted, 5 tons841.992.002.052.202.20

Source: AHRI Directory · as of

Top Coast Air models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 3 Coast Air cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1A-CAD18-1BCoast Air · A Serieswith ductless indoor unit B-CAD18-1B1.5 tons18,000 Btu/h · Non-ducted71%2.4411.512,80022.5CEE 25CEE 26XcelES CC1217187391Non-ducted, up to 1.5 tons73.1
2A-CAD09-0BCoast Air · A Serieswith ductless indoor unit B-CAD09-0B1 ton9,000 Btu/h · Non-ducted73%2.1611.57,30023.6CEE 25CEE 26XcelES CC1217187389Non-ducted, up to 1.5 tons70.6
3A-CAD12-0BCoast Air · A Serieswith ductless indoor unit B-CAD12-0B1 ton12,000 Btu/h · Non-ducted70%2.0910.28,40023.5CEE 25CEE 26XcelES CC1217187390Non-ducted, up to 1.5 tons57.5

All-around best

Top 4 Coast Air models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1A-CAD09-0BCoast Air · A Serieswith ductless indoor unit B-CAD09-0B1 ton9,000 Btu/h · Non-ducted73%2.1611.523.614.0CEE 25CEE 26XcelES CC1217187389Non-ducted, up to 1.5 tons75.670.680.570.6
2A-CAD18-1BCoast Air · A Serieswith ductless indoor unit B-CAD18-1B1.5 tons18,000 Btu/h · Non-ducted71%2.4411.522.513.7CEE 25CEE 26XcelES CC1217187391Non-ducted, up to 1.5 tons73.373.173.473.1
3A-CAD12-0BCoast Air · A Serieswith ductless indoor unit B-CAD12-0B1 ton12,000 Btu/h · Non-ducted70%2.0910.223.512.5CEE 25CEE 26XcelES CC1217187390Non-ducted, up to 1.5 tons62.057.566.557.5
4A-CAD24-1BCoast Air · A Serieswith ductless indoor unit B-CAD24-1B2 tons24,000 Btu/h · Non-ducted67%2.009.522.712.7CEE 25CEE 261217187392Non-ducted, 2 tons56.238.374.1Not a pick

Best model on each rating

Coast Air’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FA-CAD18-1B2.44Non-ducted, up to 1.5 tons98%217187391
Capacity retention at 5°FA-CAD09-0B73%Non-ducted, up to 1.5 tons38%217187389
HSPF2A-CAD09-0B11.5Non-ducted, up to 1.5 tons88%217187389
SEER2A-CAD24-1B22.7Non-ducted, 2 tons71%217187392
EER2A-CAD09-0B14.0Non-ducted, up to 1.5 tons83%217187389
Heating capacity at 5°FA-CAD18-1B12,800 Btu/hNon-ducted, up to 1.5 tons73%217187391

All 4 Coast Air models in Explore

Coast Air size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
Coast Air: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Non-ducted, up to 1.5 tons73.1(50 is the typical model of its size class)A-CAD18-1Bwith ductless indoor unit B-CAD18-1B3 of 3 models qualify · AHRI 21718739175.6(50 is the typical model of its size class)A-CAD09-0Bwith ductless indoor unit B-CAD09-0B3 of 3 models have all five ratings · AHRI 217187389
Non-ducted, 2 tonsNone on this board (0 of 1 models qualify)56.2(50 is the typical model of its size class)A-CAD24-1Bwith ductless indoor unit B-CAD24-1B1 of 1 models have all five ratings · AHRI 217187392

All-around board, every manufacturer

Newest Coast Air certifications

By AHRI reference number; AHRI issues references in increasing order.
The 4 most recently certified Coast Air outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
A-CAD24-1BCoast Air · A Serieswith ductless indoor unit B-CAD24-1B2 tons24,000 Btu/h · Non-ducted2.0067%9.522.7CEE 25CEE 261217187392
A-CAD18-1BCoast Air · A Serieswith ductless indoor unit B-CAD18-1B1.5 tons18,000 Btu/h · Non-ducted2.4471%11.522.5CEE 25CEE 26XcelES CC1217187391
A-CAD12-0BCoast Air · A Serieswith ductless indoor unit B-CAD12-0B1 ton12,000 Btu/h · Non-ducted2.0970%10.223.5CEE 25CEE 26XcelES CC1217187390
A-CAD09-0BCoast Air · A Serieswith ductless indoor unit B-CAD09-0B1 ton9,000 Btu/h · Non-ducted2.1673%11.523.6CEE 25CEE 26XcelES CC1217187389

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare Coast Air

Manufacturers of a similar size, side by side.

Coast Air includes these brand names as listed in AHRI: Coast Air. Standards are checked against published thresholds; program rules beyond ratings are not checked.