Convectair heat pump efficiency: 16 outdoor models compared
Convectair has 16 heat pump outdoor models certified with this refrigerant group, in 24 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Convectair makes. Convectair has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 16
- AHRI certifications
- 24
- Efficiency index
- 62%
- Typical model vs same-size, same-type peers (20 models)
- Meet CEE 2025
- 75%
- 12 models
How Convectair compares with comparable models
- Convectair
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index20 models scored | 62% | Not ranked | — |
| COP at 5°F20 models scored | 43% | Not ranked | 1.87 |
| Capacity retention at 5°F20 models scored | 70% | Not ranked | 89% |
| HSPF220 models scored | 69% | Not ranked | 10.2 |
| SEER220 models scored | 63% | Not ranked | 21.7 |
| EER220 models scored | 62% | Not ranked | 12.5 |
| Heating capacity at 5°F20 models scored | 68% | Not ranked | 15,750 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 75% | 12 |
| CEE 2026 Tier 1 (Split ASHP) | 75% | 12 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 75% | 12 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- Convectair (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 1 | 59% | 13% | 49% | 68% |
| Ducted, 2.5–3 tons | 2 | 73% | 22% | 89% | 88% |
| Ducted, 3.5–4.5 tons | 1 | 82% | 65% | 74% | 98% |
| Non-ducted, up to 1.5 tons | 10 | 55% | 40% | 64% | 55% |
| Non-ducted, 2 tons | 3 | 52% | 63% | 64% | 40% |
| Non-ducted, 2.5–3 tons | 2 | 78% | 40% | 92% | 81% |
| Non-ducted, 3.5–4.5 tons | 1 | 78% | 74% | 68% | 79% |
Every Convectair model in the market
- Convectair models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top Convectair models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 18028-C24-OConvectair · 8-serieswith ductless indoor unit 8028-C24-I | 2 tons24,000 Btu/h · Non-ducted | 86% | 2.21 | 11.4 | 25,000 | 21.5 | CEE 25CEE 26Xcel | 1 | 207709207 | Non-ducted, 2 tons | 84.5 |
| 28240-OConvectair · 8-serieswith ductless indoor unit 8240-I | 2 tons21,600 Btu/h · Non-ducted | 100% | 2.07 | 10.4 | 26,000 | 18.9 | CEE 25CEE 26Xcel | 1 | 206422439 | Non-ducted, 2 tons | 82.7 |
| 38422-C36-OConvectair · 8-series | 3 tons36,000 Btu/h · Non-ducted | 97% | 1.90 | 10.3 | 36,000 | 22.2 | CEE 25CEE 26Xcel | 3 | 207657622 | Non-ducted, 2.5–3 tons | 79.3 |
| 48028-C09-OConvectair · 8-serieswith ductless indoor unit 8028-C09-I | 1 ton9,000 Btu/h · Non-ducted | 88% | 1.97 | 11.5 | 10,600 | 28.1 | CEE 25CEE 26Xcel | 1 | 207709204 | Non-ducted, up to 1.5 tons | 76.2 |
| 58522-C48-OConvectair · 8-series | 4 tons48,000 Btu/h · Non-ducted | 92% | 2.00 | 9.8 | 45,000 | 21.8 | CEE 25CEE 26Xcel | 3 | 207590852 | Non-ducted, 3.5–4.5 tons | 76.2 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 18028-C09-OConvectair · 8-serieswith ductless indoor unit 8028-C09-I | 1 ton9,000 Btu/h · Non-ducted | 88% | 1.97 | 11.5 | 28.1 | 16.2 | CEE 25CEE 26Xcel | 1 | 207709204 | Non-ducted, up to 1.5 tons | 87.0 | 76.2 | 97.9 | 76.2 |
| 28028-C24-OConvectair · 8-serieswith ductless indoor unit 8028-C24-I | 2 tons24,000 Btu/h · Non-ducted | 86% | 2.21 | 11.4 | 21.5 | 13.0 | CEE 25CEE 26Xcel | 1 | 207709207 | Non-ducted, 2 tons | 84.3 | 84.5 | 84.1 | 84.5 |
| 38422-C36-OConvectair · 8-series | 3 tons36,000 Btu/h · Non-ducted | 97% | 1.90 | 10.3 | 22.2 | 13.6 | CEE 25CEE 26Xcel | 3 | 207657622 | Non-ducted, 2.5–3 tons | 82.8 | 79.3 | 86.4 | 79.3 |
| 48522-C48-OConvectair · 8-series | 4 tons47,000 Btu/h · Ducted | 87% | 2.00 | 9.0 | 20.9 | 11.7 | CEE 25CEE 26Xcel | 3 | 207590853 | Ducted, 3.5–4.5 tons | 82.0 | 74.9 | 89.1 | 74.9 |
| 58522-C48-OConvectair · 8-series | 4 tons48,000 Btu/h · Non-ducted | 92% | 2.00 | 9.8 | 21.8 | 11.7 | CEE 25CEE 26Xcel | 3 | 207590852 | Non-ducted, 3.5–4.5 tons | 77.9 | 76.2 | 79.5 | 76.2 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | 8028-C24-O | 2.21 | Non-ducted, 2 tons | 91% | 207709207 |
| Capacity retention at 5°F | 8222-C18-O | 100% | Ducted, up to 1.5 tons | 85% | 207590847 |
| HSPF2 | 8322-C27-O | 10.6 | Non-ducted, 2.5–3 tons | 95% | 207590849 |
| SEER2 | 8522-C48-O | 20.9 | Ducted, 3.5–4.5 tons | 99% | 207590853 |
| EER2 | 8028-C09-O | 16.2 | Non-ducted, up to 1.5 tons | 98% | 207709204 |
| Heating capacity at 5°F | 8222-C18-O | 20,000 Btu/h | Non-ducted, up to 1.5 tons | 96% | 207590846 |
Convectair size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 50.4(50 is the typical model of its size class)8222-C18-O1 of 1 models qualify · AHRI 207590847 | 58.6(50 is the typical model of its size class)8222-C18-O1 of 1 models have all five ratings · AHRI 207590847 |
| Ducted, 2.5–3 tons | 66.7(50 is the typical model of its size class)8322-C27-O2 of 2 models qualify · AHRI 207590850 | 74.6(50 is the typical model of its size class)8322-C27-O2 of 2 models have all five ratings · AHRI 207590850 |
| Ducted, 3.5–4.5 tons | 74.9(50 is the typical model of its size class)8522-C48-O1 of 1 models qualify · AHRI 207590853 | 82.0(50 is the typical model of its size class)8522-C48-O1 of 1 models have all five ratings · AHRI 207590853 |
| Non-ducted, up to 1.5 tons | 76.2(50 is the typical model of its size class)8028-C09-Owith ductless indoor unit 8028-C09-I8 of 10 models qualify · AHRI 207709204 | 87.0(50 is the typical model of its size class)8028-C09-Owith ductless indoor unit 8028-C09-I10 of 10 models have all five ratings · AHRI 207709204 |
| Non-ducted, 2 tons | 84.5(50 is the typical model of its size class)8028-C24-Owith ductless indoor unit 8028-C24-I2 of 3 models qualify · AHRI 207709207 | 84.3(50 is the typical model of its size class)8028-C24-Owith ductless indoor unit 8028-C24-I3 of 3 models have all five ratings · AHRI 207709207 |
| Non-ducted, 2.5–3 tons | 79.3(50 is the typical model of its size class)8422-C36-O2 of 2 models qualify · AHRI 207657622 | 82.8(50 is the typical model of its size class)8422-C36-O2 of 2 models have all five ratings · AHRI 207657622 |
| Non-ducted, 3.5–4.5 tons | 76.2(50 is the typical model of its size class)8522-C48-O1 of 1 models qualify · AHRI 207590852 | 77.9(50 is the typical model of its size class)8522-C48-O1 of 1 models have all five ratings · AHRI 207590852 |
Newest Convectair certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| 8028-C24-OConvectair · 8-serieswith ductless indoor unit 8028-C24-I | 2 tons24,000 Btu/h · Non-ducted | 2.21 | 86% | 11.4 | 21.5 | CEE 25CEE 26Xcel | 1 | 207709207 |
| 8028-C18-OConvectair · 8-serieswith ductless indoor unit 8028-C18-I | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 100% | 11.3 | 21.5 | CEE 25CEE 26Xcel | 1 | 207709206 |
| 8028-C12-OConvectair · 8-serieswith ductless indoor unit 8028-C12-I | 1 ton12,000 Btu/h · Non-ducted | 1.80 | 100% | 10.4 | 25.5 | CEE 25CEE 26Xcel | 1 | 207709205 |
| 8028-C09-OConvectair · 8-serieswith ductless indoor unit 8028-C09-I | 1 ton9,000 Btu/h · Non-ducted | 1.97 | 88% | 11.5 | 28.1 | CEE 25CEE 26Xcel | 1 | 207709204 |
| 8016-C24-OConvectairwith ductless indoor unit 8016-C24-I | 2 tons24,000 Btu/h · Non-ducted | 1.80 | 63% | 8.0 | 16.7 | None | 1 | 207709203 |
Compare Convectair
Convectair includes these brand names as listed in AHRI: Convectair. Standards are checked against published thresholds; program rules beyond ratings are not checked.