Skip to content

Convectair heat pump efficiency: 8 outdoor models compared

Convectair has 8 heat pump outdoor models certified with this refrigerant group, in 20 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Convectair makes. Convectair has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
8
AHRI certifications
20
Efficiency index
71%
Typical model vs same-size, same-type peers (12 models)
Meet CEE 2025
100%
8 models

How Convectair compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
Convectair against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of Convectair’s own modelsConvectair is strongest on capacity retention at 5°F (its typical model beats 85% of comparable models) and weakest on COP at 5°F (44%).
  • Convectair
  • Middle half of its models
  • Other ranked manufacturers
Convecta…

Source: AHRI Directory, NEEP · as of

Average peer percentile of Convectair’s models
RatingBeats comparable modelsRankRaw median
Efficiency index12 models scored71%Not ranked—
COP at 5°F12 models scored44%Not ranked2.00
Capacity retention at 5°F12 models scored85%Not ranked96%
HSPF212 models scored81%Not ranked10.5
SEER212 models scored68%Not ranked21.5
EER212 models scored75%Not ranked12.8
Heating capacity at 5°F12 models scored83%Not ranked21,000 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
Convectair’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • Convectair (median, middle 50%, 10th–90th)
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons177%63%79%83%
Ducted, 2.5–3 tons281%56%87%86%
Ducted, 3.5–4.5 tons184%54%99%96%
Non-ducted, up to 1.5 tons471%41%82%68%
Non-ducted, 2 tons173%51%95%67%
Non-ducted, 2.5–3 tons255%26%71%37%
Non-ducted, 3.5–4.5 tons163%37%57%56%

Every Convectair model in the market

Convectair’s 12 models with a known size and duct type, over the shape of the whole catalog.
Convectair models by size and ratingColoured: Convectair · grey shapes: all 14,508 models · lines: catalog medians by size
  • Convectair models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 12 convectair models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 14,508 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8261.641.711.751.852.24
Ducted, 1 ton4071.801.902.052.412.45
Ducted, 1.5 tons9921.751.862.002.172.40
Ducted, 2 tons9991.751.862.002.182.30
Ducted, 2.5 tons1,0401.701.802.002.102.36
Ducted, 3 tons6961.801.902.002.102.42
Ducted, 3.5 tons8651.701.802.002.102.46
Ducted, 4 tons7261.801.862.002.122.41
Ducted, 4.5 tons6901.701.801.902.102.20
Ducted, 5 tons861.892.002.102.102.10
Non-ducted, 0.5 tons1,1861.751.801.902.002.22
Non-ducted, 1 ton1,3431.801.801.992.102.21
Non-ducted, 1.5 tons1,2611.801.802.002.102.31
Non-ducted, 2 tons7611.801.982.002.102.30
Non-ducted, 2.5 tons4031.801.852.002.002.10
Non-ducted, 3 tons4731.901.982.002.032.20
Non-ducted, 3.5 tons2802.002.002.002.052.10
Non-ducted, 4 tons2041.962.002.052.102.11
Non-ducted, 4.5 tons781.901.911.952.012.01
Non-ducted, 5 tons841.992.002.052.202.20

Source: AHRI Directory · as of

Top Convectair models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 Convectair cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1500006193Convectair · 500 Series4 tons47,000 Btu/h · Ducted100%2.0011.048,00020.4CEE 25CEE 26XcelES CC3218001471Ducted, 3.5–4.5 tons82.7
2500006192Convectair · 500 Series3 tons36,000 Btu/h · Ducted106%2.0010.438,00019.4CEE 25CEE 26XcelES CC3218001468Ducted, 2.5–3 tons82.5
3500004494Convectair · 500 Serieswith ductless indoor unit 5000044931.5 tons18,000 Btu/h · Non-ducted100%2.0010.818,00021.7CEE 25CEE 26XcelES CC2216772610Non-ducted, up to 1.5 tons78.3
4500004496Convectair · 500 Serieswith ductless indoor unit 5000044952 tons23,000 Btu/h · Non-ducted92%2.0013.324,00022.3CEE 25CEE 26XcelES CC2216772611Non-ducted, 2 tons77.2
5500006218Convectair · 500 Series2.5 tons28,000 Btu/h · Ducted96%2.009.527,00019.0CEE 25CEE 26XcelES CC3218001465Ducted, 2.5–3 tons72.7

All-around best

Top 5 Convectair models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1500006193Convectair · 500 Series4 tons47,000 Btu/h · Ducted100%2.0011.020.411.7CEE 25CEE 26XcelES CC3218001471Ducted, 3.5–4.5 tons83.982.785.182.7
2500006192Convectair · 500 Series3 tons36,000 Btu/h · Ducted106%2.0010.419.412.0CEE 25CEE 26XcelES CC3218001468Ducted, 2.5–3 tons83.682.584.882.5
3500004490Convectair · 500 Serieswith ductless indoor unit 5000044791 ton9,000 Btu/h · Non-ducted96%1.8012.526.015.0CEE 25CEE 26XcelES CC2216772608Non-ducted, up to 1.5 tons79.565.193.865.1
4500006217Convectair · 500 Series1.5 tons19,000 Btu/h · Ducted90%2.0010.020.013.0CEE 25CEE 26XcelES CC3218001462Ducted, up to 1.5 tons77.470.884.070.8
5500006218Convectair · 500 Series2.5 tons28,000 Btu/h · Ducted96%2.009.519.012.0CEE 25CEE 26XcelES CC3218001465Ducted, 2.5–3 tons77.472.782.172.7

Best model on each rating

Convectair’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°F5000062172.00Ducted, up to 1.5 tons63%218001462
Capacity retention at 5°F500006192104%Non-ducted, 2.5–3 tons95%218001469
HSPF250000619311.0Ducted, 3.5–4.5 tons99%218001471
SEER250000619320.4Ducted, 3.5–4.5 tons96%218001471
EER250000449015.0Non-ducted, up to 1.5 tons91%216772608
Heating capacity at 5°F50000619237,400 Btu/hNon-ducted, 2.5–3 tons94%218001469

All 8 Convectair models in Explore

Convectair size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
Convectair: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons70.8(50 is the typical model of its size class)5000062171 of 1 models qualify · AHRI 21800146277.4(50 is the typical model of its size class)5000062171 of 1 models have all five ratings · AHRI 218001462
Ducted, 2.5–3 tons82.5(50 is the typical model of its size class)5000061922 of 2 models qualify · AHRI 21800146883.6(50 is the typical model of its size class)5000061922 of 2 models have all five ratings · AHRI 218001468
Ducted, 3.5–4.5 tons82.7(50 is the typical model of its size class)5000061931 of 1 models qualify · AHRI 21800147183.9(50 is the typical model of its size class)5000061931 of 1 models have all five ratings · AHRI 218001471
Non-ducted, up to 1.5 tons78.3(50 is the typical model of its size class)500004494with ductless indoor unit 5000044934 of 4 models qualify · AHRI 21677261079.5(50 is the typical model of its size class)500004490with ductless indoor unit 5000044794 of 4 models have all five ratings · AHRI 216772608
Non-ducted, 2 tons77.2(50 is the typical model of its size class)500004496with ductless indoor unit 5000044951 of 1 models qualify · AHRI 21677261172.9(50 is the typical model of its size class)500004496with ductless indoor unit 5000044951 of 1 models have all five ratings · AHRI 216772611
Non-ducted, 2.5–3 tons72.6(50 is the typical model of its size class)5000061922 of 2 models qualify · AHRI 21800146966.3(50 is the typical model of its size class)5000061922 of 2 models have all five ratings · AHRI 218001467
Non-ducted, 3.5–4.5 tons68.7(50 is the typical model of its size class)5000061931 of 1 models qualify · AHRI 21800147262.6(50 is the typical model of its size class)5000061931 of 1 models have all five ratings · AHRI 218001470

All-around board, every manufacturer

Newest Convectair certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified Convectair outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
500004496Convectair · 500 Serieswith ductless indoor unit 5000062162 tons23,000 Btu/h · Non-ducted2.0092%13.322.3CEE 25CEE 26XcelES CC2218026183
500004494Convectair · 500 Serieswith ductless indoor unit 5000062151.5 tons18,000 Btu/h · Non-ducted2.00100%10.821.7CEE 25CEE 26XcelES CC2218026182
500004492Convectair · 500 Serieswith ductless indoor unit 5000062141 ton12,000 Btu/h · Non-ducted1.8096%10.524.0CEE 25CEE 26XcelES CC2218026181
500004490Convectair · 500 Serieswith ductless indoor unit 5000062131 ton9,000 Btu/h · Non-ducted1.8096%12.526.0CEE 25CEE 26XcelES CC2218026180
500006193Convectair · 500 Series4 tons46,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0099%10.620.8CEE 25CEE 26XcelES CC3218001472

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare Convectair

Manufacturers of a similar size, side by side.

Convectair includes these brand names as listed in AHRI: Convectair. Standards are checked against published thresholds; program rules beyond ratings are not checked.