KLIMAIRE heat pump efficiency: 29 outdoor models compared

KLIMAIRE has 29 heat pump outdoor models certified with this refrigerant group, in 49 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes KLIMAIRE makes. KLIMAIRE has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

Simple view, for homeowners: top picks by size and what each rating measures →

ManufacturerData as of updated · sources

Outdoor models
29
AHRI certifications
49
Efficiency index
54%
Typical model vs same-size, same-type peers (39 models)
Meet CEE 2025
72.4%
21 models

How KLIMAIRE compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
KLIMAIRE against every ranked manufacturerPeer scores, 0 to 100 · grey ticks: each ranked manufacturer · shaded: the middle half of KLIMAIRE’s own modelsKLIMAIRE is strongest on SEER2 (its typical model beats 62% of comparable models) and weakest on COP at 5°F (48%).
  • KLIMAIRE
  • Middle half of its models
  • Other ranked manufacturers
KLIMAIRE

Source: AHRI Directory, NEEP · as of

Average peer percentile of KLIMAIRE’s models
RatingBeats comparable modelsRankRaw median
Efficiency index39 models scored54%Not ranked—
COP at 5°F39 models scored48%Not ranked2.00
Capacity retention at 5°F39 models scored49%Not ranked72%
HSPF239 models scored61%Not ranked9.5
SEER239 models scored62%Not ranked20.0
EER239 models scored49%Not ranked11.7
Heating capacity at 5°F39 models scored56%Not ranked19,000 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
KLIMAIRE’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th to 90th percentile line
  • KLIMAIRE (median, middle 50%, 10th to 90th)
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons276%75%79%83%
Ducted, 2 tons251%36%57%75%
Ducted, 2.5 to 3 tons471%51%79%88%
Ducted, 3.5 to 4.5 tons566%47%79%83%
Ducted, 5 tons and up163%67%82%89%
Non-ducted, up to 1.5 tons1049%50%54%50%
Non-ducted, 2 tons342%27%47%57%
Non-ducted, 2.5 to 3 tons746%43%54%48%
Non-ducted, 3.5 to 4.5 tons453%56%54%56%
Non-ducted, 5 tons and up127%41%18%16%

Every KLIMAIRE model in the market

KLIMAIRE’s 39 models with a known size and duct type, over the shape of the whole catalog.
KLIMAIRE models by size and ratingColoured: KLIMAIRE · grey shapes: all 15,936 models · lines: catalog medians by size
  • KLIMAIRE models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 39 klimaire models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 15,936 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8971.641.711.751.852.24
Ducted, 1 ton4631.801.862.002.412.44
Ducted, 1.5 tons1,0351.751.822.002.202.40
Ducted, 2 tons1,0731.751.862.002.182.30
Ducted, 2.5 tons1,1361.701.802.002.102.36
Ducted, 3 tons7361.801.902.002.102.42
Ducted, 3.5 tons8981.701.802.002.102.46
Ducted, 4 tons7691.801.852.002.122.39
Ducted, 4.5 tons7241.701.801.902.102.20
Ducted, 5 tons911.892.002.102.102.10
Non-ducted, 0.5 tons1,3821.751.801.902.002.21
Non-ducted, 1 ton1,6201.801.801.952.102.21
Non-ducted, 1.5 tons1,4831.801.802.002.102.28
Non-ducted, 2 tons8611.801.982.002.102.30
Non-ducted, 2.5 tons4541.801.882.002.002.21
Non-ducted, 3 tons5221.801.972.002.032.20
Non-ducted, 3.5 tons3042.002.002.002.052.10
Non-ducted, 4 tons2141.962.002.052.102.11
Non-ducted, 4.5 tons801.901.911.962.012.01
Non-ducted, 5 tons881.992.042.052.202.20

Source: AHRI Directory · as of

KLIMAIRE in the cold

From NEEP’s cold-climate listings: 24 KLIMAIRE models against all 6,343 listed models.
KLIMAIRE capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°FAt 5°F a typical KLIMAIRE model keeps 68% of its 47°F capacity; the typical listed model keeps 69%.
  • All listed models (median, middle 50% and 80%)
  • KLIMAIRE (median, middle 50%)
Heating capacity, % of its 47°F maximum68%COP at maximum capacity2.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
KLIMAIRE: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
KLIMAIRE, 47°F24100%100%100%100%100%
KLIMAIRE, 17°F2467%70%74%79%83%
KLIMAIRE, 5°F2460%65%68%72%77%
KLIMAIRE: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
KLIMAIRE, 47°F242.572.873.123.53.58
KLIMAIRE, 17°F241.972.192.242.42.61
KLIMAIRE, 5°F241.81.922.052.1

Source: NEEP ccASHP list · as of

Top KLIMAIRE models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 KLIMAIRE cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1KMHR536-H224-4KLIMAIRE · KMH Series3 tons36,000 Btu/h · Ducted106%2.0010.438,00019.4CEE 25CEE 26Xcel3217489290Ducted, 2.5 to 3 tons82.7
2KMHR648-H224-4KLIMAIRE · KMH Series4 tons47,000 Btu/h · Ducted100%2.0011.048,00020.4CEE 25CEE 26Xcel3217489293Ducted, 3.5 to 4.5 tons82.6
3KMHR660-H218-4KLIMAIRE · KMH Series4.5 tons53,000 Btu/h · Ducted87%2.1010.748,00020.0CEE 25CEE 26Xcel3217489296Ducted, 3.5 to 4.5 tons81.2
4KMIR648-H224-4KLIMAIRE · KMI Series4 tons45,000 Btu/h · Ducted81%2.1010.638,00020.4CEE 25CEE 26Xcel3217489278Ducted, 3.5 to 4.5 tons78.1
5KMIR319-H221-4KLIMAIRE · KMI Series1.5 tons18,000 Btu/h · Ducted77%2.3010.014,60020.0CEE 25CEE 26Xcel3217489269Ducted, up to 1.5 tons73.2

All-around best

Top 5 KLIMAIRE models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1KMIR648-H224-4KLIMAIRE · KMI Series4 tons45,000 Btu/h · Ducted81%2.1010.620.412.0CEE 25CEE 26Xcel3217489278Ducted, 3.5 to 4.5 tons85.378.192.678.1
2KMHR648-H224-4KLIMAIRE · KMH Series4 tons47,000 Btu/h · Ducted100%2.0011.020.411.7CEE 25CEE 26Xcel3217489293Ducted, 3.5 to 4.5 tons84.382.686.082.6
3KMHR536-H224-4KLIMAIRE · KMH Series3 tons36,000 Btu/h · Ducted106%2.0010.419.412.0CEE 25CEE 26Xcel3217489290Ducted, 2.5 to 3 tons83.982.785.182.7
4KMHR660-H218-4KLIMAIRE · KMH Series4.5 tons53,000 Btu/h · Ducted87%2.1010.720.011.7CEE 25CEE 26Xcel3217489296Ducted, 3.5 to 4.5 tons82.581.283.881.2
5KMHR319-H221-4KLIMAIRE · KMH Series1.5 tons19,000 Btu/h · Ducted90%2.0010.020.013.0CEE 25CEE 26Xcel3217489284Ducted, up to 1.5 tons77.971.384.671.3

Best model on each rating

KLIMAIRE’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FKMIR319-H221-42.25Non-ducted, up to 1.5 tons90%217489270
Capacity retention at 5°FKMHR536-H224-4104%Non-ducted, 2.5 to 3 tons95%217489291
HSPF2KMHR648-H224-411.0Ducted, 3.5 to 4.5 tons99%217489293
SEER2KMIR648-H224-420.4Ducted, 3.5 to 4.5 tons96%217489278
EER2KMHR319-H221-413.0Ducted, up to 1.5 tons85%217489284
Heating capacity at 5°FKMHR536-H224-437,400 Btu/hNon-ducted, 2.5 to 3 tons95%217489291

All 29 KLIMAIRE models in Explore

KLIMAIRE size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
KLIMAIRE: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are kept)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons73.2(50 is the typical model of its size class)KMIR319-H221-42 of 2 models qualify · AHRI 21748926977.9(50 is the typical model of its size class)KMHR319-H221-42 of 2 models have all five ratings · AHRI 217489284
Ducted, 2 tons48.1(50 is the typical model of its size class)KMIR427-H225-42 of 2 models qualify · AHRI 21748927264.6(50 is the typical model of its size class)KMIR427-H225-42 of 2 models have all five ratings · AHRI 217489272
Ducted, 2.5 to 3 tons82.7(50 is the typical model of its size class)KMHR536-H224-44 of 4 models qualify · AHRI 21748929083.9(50 is the typical model of its size class)KMHR536-H224-44 of 4 models have all five ratings · AHRI 217489290
Ducted, 3.5 to 4.5 tons82.6(50 is the typical model of its size class)KMHR648-H224-45 of 5 models qualify · AHRI 21748929385.3(50 is the typical model of its size class)KMIR648-H224-45 of 5 models have all five ratings · AHRI 217489278
Ducted, 5 tons and upNone on this board (0 of 1 models qualify)63.2(50 is the typical model of its size class)KMIR660-H218-41 of 1 models have all five ratings · AHRI 217489281
Non-ducted, up to 1.5 tons70.1(50 is the typical model of its size class)KMIP218-H225-47 of 10 models qualify · AHRI 21806707273.9(50 is the typical model of its size class)KMIP218-H225-410 of 10 models have all five ratings · AHRI 218067072
Non-ducted, 2 tons43.2(50 is the typical model of its size class)KMIR427-H225-42 of 3 models qualify · AHRI 21748927159.0(50 is the typical model of its size class)KMIR427-H225-43 of 3 models have all five ratings · AHRI 217489271
Non-ducted, 2.5 to 3 tons72.8(50 is the typical model of its size class)KMHR536-H224-45 of 7 models qualify · AHRI 21748929167.0(50 is the typical model of its size class)KMHR536-H224-47 of 7 models have all five ratings · AHRI 217489289
Non-ducted, 3.5 to 4.5 tons70.3(50 is the typical model of its size class)KMHR660-H218-44 of 4 models qualify · AHRI 21748929762.6(50 is the typical model of its size class)KMHR660-H218-44 of 4 models have all five ratings · AHRI 217489295
Non-ducted, 5 tons and upNone on this board (0 of 1 models qualify)32.9(50 is the typical model of its size class)KMIR660-H218-41 of 1 models have all five ratings · AHRI 217489280

All-around board, every manufacturer

Newest KLIMAIRE certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified KLIMAIRE outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
KOIT60H2-41GKlimairewith ducted air handler KIDT60H2-41X4.5 tons53,000 Btu/h · Ducted1.8072%8.217.0None1218082670
KOIT48H2-41GKlimairewith ducted air handler KIDT48H2-41X4.5 tons53,000 Btu/h · Ducted1.8072%8.217.0None1218082669
KOIT36H2-41GKlimairewith ducted air handler KIDT36H2-41X3 tons34,000 Btu/h · Ducted1.9076%9.019.0CEE 25CEE 26Xcel1218082668
KOIT24H2-41GKlimairewith ducted air handler KIDT24H2-41X2 tons24,000 Btu/h · Ducted1.8075%9.018.0CEE 25CEE 26Xcel1218082667
KOIQ36H2-45TKlimairewith ductless indoor unit KIWQ36H2-45T3 tons36,000 Btu/h · Non-ducted2.0357%9.019.0None1218067081

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare KLIMAIRE

Manufacturers of a similar size, side by side.

KLIMAIRE includes these brand names as listed in AHRI: KLIMAIRE. Standards are checked against published thresholds; program rules beyond ratings are not checked.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter