KLIMAIRE vs Panasonic heat pumps

Measured against models of the same size and duct type, Panasonic scores higher on 6 of the 6 ratings. KLIMAIRE has 29 outdoor models, Panasonic has 29 outdoor models. KLIMAIRE and Panasonic have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
KLIMAIRE and Panasonic on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Panasonic scores higher on 6 of the 6 ratings.
  • KLIMAIRE
  • Panasonic
  • Other ranked manufacturers
KLIMAIREPanasonic

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingKLIMAIREPanasonic
Efficiency index54%median —68%median —
COP at 5°F48%median 2.0069%median 2.08
Capacity retention at 5°F49%median 72%66%median 85%
HSPF261%median 9.578%median 10.3
SEER262%median 20.069%median 20.0
EER249%median 11.762%median 11.8
Heating capacity at 5°F56%median 19,000 Btu/h70%median 21,600 Btu/h
Outdoor models2929
AHRI certifications49289

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardKLIMAIREPanasonic
CEE 2025 Tier 1 (Split ASHP)72.4%21 models96.6%28 models
CEE 2026 Tier 1 (Split ASHP)72.4%21 models96.6%28 models
CEE Advanced Tier (Split ASHP)0%0 models20.7%6 models
Xcel Energy Colorado cold-climate ASHP (2025)69%20 models89.7%26 models
DOE Cold Climate Heat Pump Challenge0%0 models20.7%6 models
ENERGY STAR Cold Climate0%0 models93.1%27 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • KLIMAIRE
  • Panasonic
  • All models of the group
Ducted, up to 1.5 tons1.901,917 modelsDucted, 2 tons2.001,153 modelsDucted, 2.5 to 3 tons2.002,055 modelsDucted, 3.5 to 4.5 tons2.002,328 modelsDucted, 5 tons and up2.00343 modelsNon-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsNon-ducted, 5 tons and up2.0589 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeKLIMAIREPanasonic
Ducted, up to 1.5 tons2 · index 76%6 · index 68%
Ducted, 2 tons2 · index 51%3 · index 64%
Ducted, 2.5 to 3 tons4 · index 71%6 · index 64%
Ducted, 3.5 to 4.5 tons5 · index 66%5 · index 52%
Ducted, 5 tons and up1 · index 63%None
Non-ducted, up to 1.5 tons10 · index 49%9 · index 82%
Non-ducted, 2 tons3 · index 42%5 · index 74%
Non-ducted, 2.5 to 3 tons7 · index 46%2 · index 60%
Non-ducted, 3.5 to 4.5 tons4 · index 53%1 · index 51%
Non-ducted, 5 tons and up1 · index 27%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeKLIMAIRECold-climate score, best modelPanasonicCold-climate score, best model
Ducted, up to 1.5 tons73.0(50 is the typical model of its size class)KMIR319-H221-42 of 2 models qualify · AHRI 21748926980.4(50 is the typical model of its size class) (higher)CU-YM9CBUCwith ducted air handler CS-YM9CD2UW5 of 6 models qualify · AHRI 218027968
Ducted, 2 tons48.0(50 is the typical model of its size class)KMIR427-H225-42 of 2 models qualify · AHRI 21748927277.1(50 is the typical model of its size class) (higher)CU-YM24CBUCwith ducted air handler CS-YM24CD1UW3 of 3 models qualify · AHRI 218027971
Ducted, 2.5 to 3 tons82.7(50 is the typical model of its size class)KMHR536-H224-44 of 4 models qualify · AHRI 21748929083.4(50 is the typical model of its size class) (higher)CU-5YM36CBUC5 of 6 models qualify · AHRI 218027980
Ducted, 3.5 to 4.5 tons82.6(50 is the typical model of its size class)KMHR648-H224-45 of 5 models qualify · AHRI 21748929382.6(50 is the typical model of its size class)CU-6YM48CBUC5 of 5 models qualify · AHRI 218027983
Ducted, 5 tons and upNone on this board (0 of 1 models qualify)No models in this size class
Non-ducted, up to 1.5 tons70.1(50 is the typical model of its size class)KMIP218-H225-47 of 10 models qualify · AHRI 21806707295.4(50 is the typical model of its size class) (higher)CU-XZ9AKUACwith ductless indoor unit CS-XZ9AKUAW9 of 9 models qualify · AHRI 214837752
Non-ducted, 2 tons43.2(50 is the typical model of its size class)KMIR427-H225-42 of 3 models qualify · AHRI 21748927191.6(50 is the typical model of its size class) (higher)CU-3Z22ABUC4 of 4 models qualify · AHRI 214837935
Non-ducted, 2.5 to 3 tons72.8(50 is the typical model of its size class)KMHR536-H224-45 of 7 models qualify · AHRI 21748929173.2(50 is the typical model of its size class) (higher)CU-5YM36CBUC3 of 3 models qualify · AHRI 218027981
Non-ducted, 3.5 to 4.5 tons70.3(50 is the typical model of its size class) (higher)KMHR660-H218-44 of 4 models qualify · AHRI 21748929769.1(50 is the typical model of its size class)CU-6YM48CBUC1 of 1 models qualify · AHRI 218027984
Non-ducted, 5 tons and upNone on this board (0 of 1 models qualify)No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeKLIMAIREAll-around score, best modelPanasonicAll-around score, best model
Ducted, up to 1.5 tons77.8(50 is the typical model of its size class)KMHR319-H221-42 of 2 models have all five ratings · AHRI 21748928479.0(50 is the typical model of its size class) (higher)CU-YM18CBUCwith ducted air handler CS-YM18CD1UW6 of 6 models have all five ratings · AHRI 218027970
Ducted, 2 tons64.6(50 is the typical model of its size class)KMIR427-H225-42 of 2 models have all five ratings · AHRI 21748927278.9(50 is the typical model of its size class) (higher)CU-YM24CBUCwith ducted air handler CS-YM24CD1UW3 of 3 models have all five ratings · AHRI 218027971
Ducted, 2.5 to 3 tons83.9(50 is the typical model of its size class)KMHR536-H224-44 of 4 models have all five ratings · AHRI 21748929084.3(50 is the typical model of its size class) (higher)CU-5YM36CBUC6 of 6 models have all five ratings · AHRI 218027980
Ducted, 3.5 to 4.5 tons85.3(50 is the typical model of its size class)KMIR648-H224-45 of 5 models have all five ratings · AHRI 21748927885.3(50 is the typical model of its size class)CU - 6YM48CBUC5 of 5 models have all five ratings · AHRI 218214188
Ducted, 5 tons and up63.2(50 is the typical model of its size class)KMIR660-H218-41 of 1 models have all five ratings · AHRI 217489281No models in this size class
Non-ducted, up to 1.5 tons74.0(50 is the typical model of its size class)KMIP218-H225-410 of 10 models have all five ratings · AHRI 21806707296.3(50 is the typical model of its size class) (higher)CU-XZ9AKUACwith ductless indoor unit CS-XZ9AKUAW9 of 9 models have all five ratings · AHRI 214837752
Non-ducted, 2 tons59.0(50 is the typical model of its size class)KMIR427-H225-43 of 3 models have all five ratings · AHRI 21748927188.5(50 is the typical model of its size class) (higher)CU-3Z22ABUC5 of 5 models have all five ratings · AHRI 214837935
Non-ducted, 2.5 to 3 tons67.0(50 is the typical model of its size class)KMHR536-H224-47 of 7 models have all five ratings · AHRI 21748928967.0(50 is the typical model of its size class)CU-5YM36CBUC2 of 2 models have all five ratings · AHRI 218027979
Non-ducted, 3.5 to 4.5 tons62.6(50 is the typical model of its size class)KMHR660-H218-44 of 4 models have all five ratings · AHRI 21748929562.8(50 is the typical model of its size class) (higher)CU-6YM48CBUC1 of 1 models have all five ratings · AHRI 218027982
Non-ducted, 5 tons and up32.9(50 is the typical model of its size class)KMIR660-H218-41 of 1 models have all five ratings · AHRI 217489280No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingKLIMAIREPanasonic
COP at 5°Fbeats 90% · 2.25KMIR319-H221-4Non-ducted, up to 1.5 tonsbeats 99% · 2.51CU-YM12CBUCNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 95% · 104%KMHR536-H224-4Non-ducted, 2.5 to 3 tonsbeats 100% · 113%CU-4Z24BBUCNon-ducted, 2 tons
HSPF2beats 99% · 11.0KMHR648-H224-4Ducted, 3.5 to 4.5 tonsbeats 99% · 11.0CU-6YM48CBUCDucted, 3.5 to 4.5 tons
SEER2beats 96% · 20.4KMIR648-H224-4Ducted, 3.5 to 4.5 tonsbeats 97% · 27.5CU-XZ9AKUACNon-ducted, up to 1.5 tons
EER2beats 85% · 13.0KMHR319-H221-4Ducted, up to 1.5 tonsbeats 98% · 16.4CU-XZ9AKUACNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 95% · 37,400 Btu/hKMHR536-H224-4Non-ducted, 2.5 to 3 tonsbeats 99% · 22,000 Btu/hCU-2Z18ABUCNon-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
KLIMAIRE vs Panasonic: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.7% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • KLIMAIRE (median, middle 50%)
  • Panasonic (median, middle 50%)
Heating capacity, % of its 47°F maximum68%65%COP at maximum capacity2.002.08

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
KLIMAIRE: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
KLIMAIRE, 47°F24100%100%100%100%100%
KLIMAIRE, 17°F2467%70%74%79%83%
KLIMAIRE, 5°F2460%65%68%72%77%
KLIMAIRE: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
KLIMAIRE, 47°F242.572.873.123.53.58
KLIMAIRE, 17°F241.972.192.242.42.61
KLIMAIRE, 5°F241.81.922.052.1
Panasonic: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Panasonic, 47°F29100%100%100%100%100%
Panasonic, 17°F2965%68%72%75%83%
Panasonic, 5°F2956%59%65%72%79%
Panasonic: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Panasonic, 47°F293.083.223.33.523.66
Panasonic, 17°F292.022.242.42.52.63
Panasonic, 5°F291.871.962.082.242.32

Source: NEEP ccASHP list · as of