- Insights
- Manufacturers
- Cooper&Hunter
Both views use the same certified data. This device remembers your choice.
Cooper&Hunter heat pump efficiency: 57 outdoor models compared
Cooper&Hunter has 57 heat pump outdoor models certified with this refrigerant group, in 408 AHRI-certified combinations. They are also sold as C&H. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Cooper&Hunter makes. Ranks are among manufacturers with a QMID on file and at least 10 scored models.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 57
- AHRI certifications
- 408
- Efficiency index
- 58%
- Typical model vs same-size, same-type peers (75 models)
- Meet CEE 2025
- 57.9%
- 33 models
How Cooper&Hunter compares with comparable models
- Cooper&Hunter
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index75 models scored | 58% | 10th of 27 | — |
| COP at 5°F75 models scored | 56% | 11th of 27 | 2.00 |
| Capacity retention at 5°F75 models scored | 57% | 13th of 27 | 70% |
| HSPF286 models scored | 64% | 8th of 27 | 9.4 |
| SEER286 models scored | 56% | 10th of 27 | 19.8 |
| EER286 models scored | 45% | 22nd of 27 | 10.5 |
| Heating capacity at 5°F75 models scored | 54% | 14th of 27 | 17,500 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 57.9% | 33 |
| CEE 2026 Tier 1 (Split ASHP) | 56.1% | 32 |
| CEE Advanced Tier (Split ASHP) | 1.8% | 1 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 45.6% | 26 |
| DOE Cold Climate Heat Pump Challenge | 1.8% | 1 |
| ENERGY STAR Cold Climate | 42.1% | 24 |
Sizes and duct types offered
- Cooper&Hunter (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 8 | 68% | 53% | 77% | 75% |
| Ducted, 2 tons | 2 | 82% | 65% | 96% | 87% |
| Ducted, 2.5 to 3 tons | 10 | 56% | 41% | 75% | 62% |
| Ducted, 3.5 to 4.5 tons | 10 | 58% | 44% | 85% | 60% |
| Ducted, 5 tons and up | 3 | 55% | 65% | 69% | 67% |
| Non-ducted, up to 1.5 tons | 24 | 57% | 68% | 61% | 56% |
| Non-ducted, 2 tons | 5 | 48% | 55% | 37% | 46% |
| Non-ducted, 2.5 to 3 tons | 13 | 60% | 54% | 55% | 47% |
| Non-ducted, 3.5 to 4.5 tons | 11 | 49% | 47% | 50% | 42% |
Every Cooper&Hunter model in the market
- Cooper&Hunter models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 179 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 354 | 1.85 | 1.89 | 2.00 | 2.40 | 2.63 |
| Ducted, 1.5 tons | 802 | 1.75 | 1.85 | 2.00 | 2.20 | 2.52 |
| Ducted, 2 tons | 791 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 758 | 1.70 | 1.80 | 1.90 | 2.10 | 2.44 |
| Ducted, 3 tons | 674 | 1.68 | 1.73 | 1.90 | 2.06 | 2.34 |
| Ducted, 3.5 tons | 662 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 373 | 1.70 | 1.80 | 1.91 | 2.02 | 2.50 |
| Ducted, 4.5 tons | 575 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 29 | 1.80 | 1.80 | 1.86 | 1.90 | 2.10 |
| Non-ducted, 0.5 tons | 774 | 1.75 | 1.80 | 1.94 | 2.09 | 2.19 |
| Non-ducted, 1 ton | 1,135 | 1.75 | 1.80 | 1.89 | 2.07 | 2.24 |
| Non-ducted, 1.5 tons | 946 | 1.75 | 1.80 | 1.87 | 2.07 | 2.20 |
| Non-ducted, 2 tons | 598 | 1.78 | 1.80 | 1.83 | 2.00 | 2.21 |
| Non-ducted, 2.5 tons | 327 | 1.75 | 1.80 | 1.84 | 1.86 | 2.02 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.80 | 1.90 | 2.00 | 2.07 |
| Non-ducted, 3.5 tons | 71 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 269 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 106 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 31 | 1.89 | 2.00 | 2.07 | 2.30 | 2.40 |
Source: AHRI Directory · as of
Cooper&Hunter in the cold
- All listed models (median, middle 50% and 80%)
- Cooper&Hunter (median, middle 50%)
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 3,710 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 3,710 | 65% | 68% | 76% | 83% | 92% |
| All rated models, 5°F | 3,710 | 55% | 58% | 66% | 75% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 3,710 | 2.64 | 2.87 | 3.1 | 3.32 | 3.53 |
| All rated models, 17°F | 3,710 | 1.98 | 2.05 | 2.2 | 2.34 | 2.49 |
| All rated models, 5°F | 3,710 | 1.8 | 1.83 | 1.92 | 2.03 | 2.21 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Cooper&Hunter, 47°F | 38 | 100% | 100% | 100% | 100% | 100% |
| Cooper&Hunter, 17°F | 38 | 66% | 67% | 72% | 79% | 81% |
| Cooper&Hunter, 5°F | 38 | 55% | 56% | 62% | 72% | 81% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Cooper&Hunter, 47°F | 38 | 2.72 | 2.93 | 3.06 | 3.29 | 3.54 |
| Cooper&Hunter, 17°F | 38 | 1.98 | 2.07 | 2.22 | 2.4 | 2.42 |
| Cooper&Hunter, 5°F | 38 | 1.8 | 1.84 | 2 | 2.07 | 2.24 |
Source: NEEP ccASHP list · as of
Top Cooper&Hunter models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1CH-HPR06F9-230VOC&H · CH serieswith ductless indoor unit CH-06MASTWM-230VI | 0.5 tons6,000 Btu/h · Non-ducted | 107% | 2.09 | 13.6 | 7,500 | 26.5 | CEE 25CEE 26XcelES CC | 8 | 207740500 | Non-ducted, up to 1.5 tons | 89.8 |
| 2CH-HPR24-230VOC&H · CH serieswith ductless indoor unit CH-N24MSPHCT-230VI | 2 tons24,000 Btu/h · Non-ducted | 103% | 2.00 | 11.5 | 25,800 | 20.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 20 | 207742335 | Non-ducted, 2 tons | 87.1 |
| 3CH-ES09-230VOC&H · CH serieswith ductless indoor unit CH-09MASTWM-230VI | 1 ton9,000 Btu/h · Non-ducted | 86% | 2.19 | 12.3 | 8,581 | 25.5 | CEE 25CEE 26XcelES CC | 15 | 209937047 | Non-ducted, up to 1.5 tons | 86.6 |
| 4CH-HYP48LCUOC&H · CH serieswith ducted air handler CH-48LCDTU/IAlso listed as CH-NHPR48LCU-230VO | 4 tons48,000 Btu/h · Ducted | 88% | 2.02 | 10.3 | 46,000 | 14.3 | None | 10 | 205263864 | Ducted, 3.5 to 4.5 tons | 86.5 |
| 5CH-NHPR60LCU-230VOCooper&Hunter · CH serieswith ducted air handler CH-60LCDTU/I | 4.5 tons55,000 Btu/h · Ducted | 93% | 1.97 | 9.5 | 53,000 | 15.8 | ES CC | 6 | 211246028 | Ducted, 3.5 to 4.5 tons | 82.2 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1CH-HPR06F9-230VOC&H · CH serieswith ductless indoor unit CH-06MASTWM-230VI | 0.5 tons6,000 Btu/h · Non-ducted | 107% | 2.09 | 13.6 | 26.5 | 15.8 | CEE 25CEE 26XcelES CC | 8 | 207740500 | Non-ducted, up to 1.5 tons | 92.3 | 89.8 | 94.7 | 89.8 |
| 2CH-ES09-230VOC&H · CH serieswith ductless indoor unit CH-09MASTWM-230VI | 1 ton9,000 Btu/h · Non-ducted | 86% | 2.19 | 12.3 | 25.5 | 15.0 | CEE 25CEE 26XcelES CC | 15 | 209937047 | Non-ducted, up to 1.5 tons | 88.8 | 86.6 | 90.9 | 86.6 |
| 3CH-HPR09-230VOC&H · CH serieswith ductless indoor unit CH-09MASTWM-230VI | 1 ton9,000 Btu/h · Non-ducted | 88% | 1.97 | 11.5 | 28.1 | 16.2 | CEE 25CEE 26XcelES CC | 17 | 207740501 | Non-ducted, up to 1.5 tons | 87.6 | 77.3 | 97.9 | 77.3 |
| 4CH-HPR09-230VOC&H · CH serieswith ducted air handler CH-M09DTUI | 1 ton9,000 Btu/h · Ducted | 108% | 1.90 | 12.0 | 20.2 | 13.2 | CEE 25CEE 26XcelES CC | 17 | 207742328 | Ducted, up to 1.5 tons | 85.4 | 75.2 | 95.5 | 75.2 |
| 5CH-HPR24-230VOC&H · CH serieswith ductless indoor unit CH-24MASTWM-230VI | 2 tons24,000 Btu/h · Non-ducted | 86% | 2.21 | 11.4 | 21.5 | 13.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 20 | 207740504 | Non-ducted, 2 tons | 84.9 | 85.5 | 84.3 | 87.1 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | CH-ES12-230VO | 2.45 | Non-ducted, up to 1.5 tons | 98% | 209937051 |
| Capacity retention at 5°F | CH-NHPR48LCU-230VO | 97% | Ducted, 3.5 to 4.5 tons | 97% | 208141208 |
| HSPF2 | CH-HYP48LCUOAlso listed as CH-NHPR48LCU-230VO | 10.3 | Ducted, 3.5 to 4.5 tons | 99% | 205263864 |
| SEER2 | CH-HPR48M-230VO | 20.9 | Ducted, 3.5 to 4.5 tons | 99% | 207742382 |
| EER2 | CH-HPR09-230VO | 16.2 | Non-ducted, up to 1.5 tons | 98% | 207740501 |
| Heating capacity at 5°F | CH-NHPR60LCU-230VO | 57,600 Btu/h | Ducted, 3.5 to 4.5 tons | 100% | 211246029 |
Cooper&Hunter size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 75.2(50 is the typical model of its size class)CH-HPR09-230VOwith ducted air handler CH-M09DTUI7 of 8 models qualify · AHRI 207742328 | 85.4(50 is the typical model of its size class)CH-HPR09-230VOwith ducted air handler CH-M09DTUI8 of 8 models have all five ratings · AHRI 207742328 |
| Ducted, 2 tons | 80.6(50 is the typical model of its size class)CH-ES24-230VOwith ducted air handler CH-M24DTUI2 of 2 models qualify · AHRI 207742325 | 84.0(50 is the typical model of its size class)CH-ES24-230VOwith ducted air handler CH-M24DTUI2 of 2 models have all five ratings · AHRI 207742325 |
| Ducted, 2.5 to 3 tons | 80.0(50 is the typical model of its size class)CH-HYP36LCUOwith ducted air handler CH-36LCDTU/IAlso listed as CH-NHPR36LCU-230VO4 of 10 models qualify · AHRI 205901586 | 75.4(50 is the typical model of its size class)CH-28MES-230VO8 of 10 models have all five ratings · AHRI 207742365 |
| Ducted, 3.5 to 4.5 tons | 86.5(50 is the typical model of its size class)CH-HYP48LCUOwith ducted air handler CH-48LCDTU/IAlso listed as CH-NHPR48LCU-230VO5 of 10 models qualify · AHRI 205263864 | 82.1(50 is the typical model of its size class)CH-HPR48M-230VO8 of 10 models have all five ratings · AHRI 207742382 |
| Ducted, 5 tons and up | None on this board (0 of 3 models qualify) | 57.2(50 is the typical model of its size class)CH-N60LCU-230VOwith ducted air handler CH-60LCDTU/I3 of 3 models have all five ratings · AHRI 207742344 |
| Non-ducted, up to 1.5 tons | 89.8(50 is the typical model of its size class)CH-HPR06F9-230VOwith ductless indoor unit CH-06MASTWM-230VI14 of 24 models qualify · AHRI 207740500 | 92.3(50 is the typical model of its size class)CH-HPR06F9-230VOwith ductless indoor unit CH-06MASTWM-230VI24 of 24 models have all five ratings · AHRI 207740500 |
| Non-ducted, 2 tons | 87.1(50 is the typical model of its size class)CH-HPR24-230VOwith ductless indoor unit CH-N24MSPHCT-230VI3 of 5 models qualify · AHRI 207742335 | 84.9(50 is the typical model of its size class)CH-HPR24-230VOwith ductless indoor unit CH-24MASTWM-230VI5 of 5 models have all five ratings · AHRI 207740504 |
| Non-ducted, 2.5 to 3 tons | 80.2(50 is the typical model of its size class)CH-HPR36M-230VO4 of 13 models qualify · AHRI 207742379 | 83.4(50 is the typical model of its size class)CH-HPR36M-230VO9 of 13 models have all five ratings · AHRI 207742379 |
| Non-ducted, 3.5 to 4.5 tons | 76.8(50 is the typical model of its size class)CH-NHPR60LCU-230VOwith ductless indoor unit CH-60LCFC/I5 of 11 models qualify · AHRI 211246027 | 78.0(50 is the typical model of its size class)CH-HPR48M-230VO8 of 11 models have all five ratings · AHRI 207742381 |
Newest Cooper&Hunter certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| CH-HYP36LCUOCooper&Hunterwith ductless indoor unit CH-36LCCT-230VI | 3 tons36,000 Btu/h · Ducted and non-ducted | — | — | 9.0 | 18.0 | ES CC | 3 | 215374899 |
| CH-NY09MIA-115VOCooper&Hunter · CH-serieswith ductless indoor unit CH-NY09MIA-SK115V | 1 ton9,000 Btu/h · Non-ducted | 1.92 | 66% | 9.0 | 21.5 | CEE 25CEE 26XcelES CC | 5 | 214312549 |
| CH-NY18MIA-230VOCooper&Hunterwith ductless indoor unit CH-NY18MIA-SK230V | 1.5 tons18,000 Btu/h · Non-ducted | 2.18 | 64% | 8.7 | 19.0 | CEE 25CEE 26 | 5 | 214312548 |
| CH-NY12MIA-230VOCooper&Hunterwith ductless indoor unit CH-NY12MIA-SK230V | 1 ton12,000 Btu/h · Non-ducted | 1.68 | 45% | 9.1 | 21.4 | CEE 25CEE 26 | 5 | 214312547 |
| CH-NY09MIA-230VOCooper&Hunter · CH-serieswith ductless indoor unit CH-NY09MIA-SK230V | 1 ton9,000 Btu/h · Non-ducted | 1.95 | 64% | 9.1 | 21.7 | CEE 25CEE 26XcelES CC | 5 | 214312546 |
Compare Cooper&Hunter
Cooper&Hunter includes these brand names as listed in AHRI: C&H, Cooper&Hunter. Standards are checked against published thresholds; program rules beyond ratings are not checked.