Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Dettson heat pumps: how do their ratings compare?
A typical Dettson heat pump beats 52% of similar heat pumps (same size and type), which is about average. Dettson has 10 heat pump models in this list.
Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated
Overall score
52%
of similar heat pumps beaten by its typical model
About averageDettson has no QMID (the manufacturer ID the 25C tax credit needs) on file, so it is not ranked against other brands. Based on 10 models with every rating.
- Efficiency on a 5°F dayCOP at 5°FBeats 55%
- Heating power kept at 5°FCapacity at 5°F vs 47°FBeats 71%
- Winter-long heating efficiencyHSPF2Beats 78%
- Summer-long cooling efficiencySEER2Beats 42%
- Hot-day cooling efficiencyEER2Beats 30%
Average (50%)
Each bar: the share of similar heat pumps a typical model beats on that rating.
Want Dettson’s ranks and its models inside every size class? Switch to Advanced
Rebate standards
60%
meet CEE 2025 Tier 1, the level many utility rebates use.
6 models. All brands: 48%.
80%
meet Xcel Energy Colorado’s cold-climate rebate levels.
8 models. All brands: 38%.
0%
reach the cold-climate tier: full heating output and a COP of 2.1 or more at 5°F.
None of its models yet. All brands: 1%.
Top Dettson cold-climate picks, by size
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
Showing Ducted, Up to 1.5 tons (under 21,000 Btu/h cooling). What size is my system?
3 of Dettson’s 3 models of this size and type qualify.
- 1EVD-24-O*with ducted air handler MAC24H1418EDettson1.5 tons · 20,000 Btu/h · DuctedKeeps 80% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 80% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Seasonal efficiency
- 10.2 (HSPF2)
- Great
- 2EVD-18-Owith ducted air handler MAC24H1718EDettson1.5 tons · 18,000 Btu/h · DuctedKeeps 79% of its heat at 5°FMeets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 79% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.20 (COP at 5°F)
- Great
- Seasonal efficiency
- 9.5 (HSPF2)
- Good
- 3MHD-18with ducted air handler MHD-CC2.0-17.5-MDettson1.5 tons · 18,000 Btu/h · DuctedKeeps 75% of its heat at 5°FMeets Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 75% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.21 (COP at 5°F)
- Great
- Seasonal efficiency
- 9.5 (HSPF2)
- Good
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
What to do next
The advanced view has Dettson’s ranks on each rating, its models inside every size and type, cold-weather curves and its newest certifications.
Open the advanced view