- Insights
- Manufacturers
- ECO-AIR
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
ECO-AIR heat pump efficiency: 58 outdoor models compared
ECO-AIR has 58 heat pump outdoor models certified with this refrigerant group, in 142 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes ECO-AIR makes. ECO-AIR has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 58
- AHRI certifications
- 142
- Efficiency index
- 56%
- Typical model vs same-size, same-type peers (82 models)
- Meet CEE 2025
- 62.1%
- 36 models
How ECO-AIR compares with comparable models
- ECO-AIR
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index82 models scored | 56% | Not ranked | — |
| COP at 5°F82 models scored | 51% | Not ranked | 1.98 |
| Capacity retention at 5°F82 models scored | 53% | Not ranked | 68% |
| HSPF282 models scored | 69% | Not ranked | 9.4 |
| SEER282 models scored | 62% | Not ranked | 19.3 |
| EER282 models scored | 47% | Not ranked | 10.9 |
| Heating capacity at 5°F82 models scored | 56% | Not ranked | 20,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 62.1% | 36 |
| CEE 2026 Tier 1 (Split ASHP) | 58.6% | 34 |
| CEE Advanced Tier (Split ASHP) | 1.7% | 1 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 44.8% | 26 |
| DOE Cold Climate Heat Pump Challenge | 1.7% | 1 |
| ENERGY STAR Cold Climate | 50% | 29 |
Sizes and duct types offered
- ECO-AIR (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 12 | 61% | 54% | 72% | 66% |
| Ducted, 2 tons | 4 | 70% | 64% | 92% | 73% |
| Ducted, 2.5–3 tons | 15 | 53% | 43% | 74% | 61% |
| Ducted, 3.5–4.5 tons | 10 | 56% | 39% | 84% | 66% |
| Ducted, 5 tons and up | 2 | 49% | 49% | 77% | 61% |
| Non-ducted, up to 1.5 tons | 18 | 55% | 59% | 62% | 59% |
| Non-ducted, 2 tons | 5 | 53% | 62% | 56% | 55% |
| Non-ducted, 2.5–3 tons | 10 | 58% | 53% | 61% | 62% |
| Non-ducted, 3.5–4.5 tons | 6 | 52% | 40% | 52% | 62% |
Every ECO-AIR model in the market
- ECO-AIR models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top ECO-AIR models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1MOX230-09HFN1-MW5WECO-AIR · MOX Serieswith ductless indoor unit MSEPB-06HRFN1-MY5W | 0.5 tons6,000 Btu/h · Non-ducted | 107% | 2.09 | 13.6 | 7,500 | 26.5 | CEE 25CEE 26XcelES CC | 5 | 208121863 | Non-ducted, up to 1.5 tons | 89.3 |
| 2M4OX630-36HFN1-M1XECO-AIR · M40 Series | 3 tons36,000 Btu/h · Non-ducted | 100% | 1.95 | 10.9 | 36,000 | 21.0 | CEE 25CEE 26XcelES CC | 3 | 213307915 | Non-ducted, 2.5–3 tons | 87.0 |
| 3MOX430U-18HFN1-MECO-AIR · MOX Serieswith ducted air handler MVBE-18HWFN1-MM3E | 1.5 tons18,000 Btu/h · Ducted | 99% | 2.30 | 10.8 | 18,800 | 19.3 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 213307908 | Ducted, up to 1.5 tons | 86.9 |
| 4MOE30U-48HFN1-M-[X](GA)ECO-AIR · MOE Serieswith ducted air handler MTI-48HWFN1-M | 4 tons48,000 Btu/h · Ducted | 88% | 2.02 | 10.3 | 46,000 | 14.3 | None | 2 | 211644067 | Ducted, 3.5–4.5 tons | 86.4 |
| 5MOD30-24HFN1-MU0WECO-AIR · MOD Serieswith ductless indoor unit MCD1-24HRFN1-MT0W(GA) | 2 tons24,000 Btu/h · Non-ducted | 103% | 2.00 | 11.5 | 25,800 | 20.5 | CEE 25CEE 26XcelES CC | 4 | 211644071 | Non-ducted, 2 tons | 86.1 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1MOX230-09HFN1-MW5WECO-AIR · MOX Serieswith ductless indoor unit MSEPB-06HRFN1-MY5W | 0.5 tons6,000 Btu/h · Non-ducted | 107% | 2.09 | 13.6 | 26.5 | 15.8 | CEE 25CEE 26XcelES CC | 5 | 208121863 | Non-ducted, up to 1.5 tons | 92.0 | 89.3 | 94.6 | 89.3 |
| 2MOX330-09HFN1-MY5WECO-AIR · MOX Serieswith ductless indoor unit MSEPB-09HRFN1-MY5W(GA) | 1 ton9,000 Btu/h · Non-ducted | 88% | 1.97 | 11.5 | 28.1 | 16.2 | CEE 25CEE 26XcelES CC | 4 | 208121864 | Non-ducted, up to 1.5 tons | 87.0 | 76.2 | 97.9 | 76.2 |
| 3MOX330-09HFN1-MY5WECO-AIR · MOX Serieswith ducted air handler MTIU-09HWFN1-M | 1 ton9,000 Btu/h · Ducted | 108% | 1.90 | 12.0 | 20.2 | 13.2 | CEE 25CEE 26XcelES CC | 4 | 211644062 | Ducted, up to 1.5 tons | 85.2 | 74.9 | 95.5 | 74.9 |
| 4MOD30-24HFN1-MU0WECO-AIR · MOD Serieswith ductless indoor unit MSEPD-24HRFN1-MU0W | 2 tons24,000 Btu/h · Non-ducted | 86% | 2.21 | 11.4 | 21.5 | 13.0 | CEE 25CEE 26XcelES CC | 4 | 208121867 | Non-ducted, 2 tons | 84.3 | 84.5 | 84.1 | 86.1 |
| 5MOD33-24HFN1-MT0WECO-AIR · MOD Serieswith ducted air handler MTIU-24HWFN1-M | 2 tons23,000 Btu/h · Ducted | 80% | 2.30 | 11.2 | 19.0 | 12.5 | CEE 25CEE 26XcelES CC | 4 | 211644052 | Ducted, 2 tons | 83.8 | 80.3 | 87.4 | 80.3 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | MOX230-12HFN1-MV5W | 2.45 | Non-ducted, up to 1.5 tons | 98% | 211644090 |
| Capacity retention at 5°F | MOX430U-18HFN1-M | 111% | Ducted, up to 1.5 tons | 97% | 213369644 |
| HSPF2 | MOE30U-48HFN1-M-[X](GA) | 10.3 | Ducted, 3.5–4.5 tons | 99% | 211644067 |
| SEER2 | M3OJ-27HFN1-M | 24.6 | Non-ducted, 2.5–3 tons | 99% | 208121871 |
| EER2 | MOX330-09HFN1-MY5W | 16.2 | Non-ducted, up to 1.5 tons | 98% | 208121864 |
| Heating capacity at 5°F | MOE30U-36HFN1-M(GA) | 41,000 Btu/h | Non-ducted, 2.5–3 tons | 98% | 211644072 |
ECO-AIR size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 86.9(50 is the typical model of its size class)MOX430U-18HFN1-Mwith ducted air handler MVBE-18HWFN1-MM3E9 of 12 models qualify · AHRI 213307908 | 85.2(50 is the typical model of its size class)MOX330-09HFN1-MY5Wwith ducted air handler MTIU-09HWFN1-M12 of 12 models have all five ratings · AHRI 211644062 |
| Ducted, 2 tons | 80.3(50 is the typical model of its size class)MOD33-24HFN1-MT0Wwith ducted air handler MTIU-24HWFN1-M4 of 4 models qualify · AHRI 211644052 | 83.8(50 is the typical model of its size class)MOD33-24HFN1-MT0Wwith ducted air handler MTIU-24HWFN1-M4 of 4 models have all five ratings · AHRI 211644052 |
| Ducted, 2.5–3 tons | 79.9(50 is the typical model of its size class)MOE30U-36HFN1-M(GA)with ducted air handler MTI-36HWFN1-M7 of 15 models qualify · AHRI 211644066 | 83.7(50 is the typical model of its size class)M4OX630-36HFN1-M1X15 of 15 models have all five ratings · AHRI 213307916 |
| Ducted, 3.5–4.5 tons | 86.4(50 is the typical model of its size class)MOE30U-48HFN1-M-[X](GA)with ducted air handler MTI-48HWFN1-M7 of 11 models qualify · AHRI 211644067 | 82.0(50 is the typical model of its size class)M5OG-48HFN1-M-[X]11 of 11 models have all five ratings · AHRI 209319648 |
| Ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 57.1(50 is the typical model of its size class)MOE30U-60HFN1-M(GA)(X)with ducted air handler MHG-60HWFN1-MW1 of 1 models have all five ratings · AHRI 211644055 |
| Non-ducted, up to 1.5 tons | 89.3(50 is the typical model of its size class)MOX230-09HFN1-MW5Wwith ductless indoor unit MSEPB-06HRFN1-MY5W9 of 18 models qualify · AHRI 208121863 | 92.0(50 is the typical model of its size class)MOX230-09HFN1-MW5Wwith ductless indoor unit MSEPB-06HRFN1-MY5W18 of 18 models have all five ratings · AHRI 208121863 |
| Non-ducted, 2 tons | 86.1(50 is the typical model of its size class)MOD30-24HFN1-MU0Wwith ductless indoor unit MCD1-24HRFN1-MT0W(GA)2 of 5 models qualify · AHRI 211644071 | 84.3(50 is the typical model of its size class)MOD30-24HFN1-MU0Wwith ductless indoor unit MSEPD-24HRFN1-MU0W5 of 5 models have all five ratings · AHRI 208121867 |
| Non-ducted, 2.5–3 tons | 87.0(50 is the typical model of its size class)M4OX630-36HFN1-M1X4 of 10 models qualify · AHRI 213307915 | 82.8(50 is the typical model of its size class)M4OI-36HFN1-M10 of 10 models have all five ratings · AHRI 209319644 |
| Non-ducted, 3.5–4.5 tons | 76.2(50 is the typical model of its size class)M5OG-48HFN1-M-[X]3 of 6 models qualify · AHRI 209319647 | 77.9(50 is the typical model of its size class)M5OG-48HFN1-M-[X]6 of 6 models have all five ratings · AHRI 209319647 |
Newest ECO-AIR certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| MOX330-12HFN1-MW5WECO-AIR · MOX Serieswith ductless indoor unit MFA2U-12HRFN1-MW5W | 1 ton12,000 Btu/h · Ducted and non-ducted | 1.99 | 99% | 10.7 | 24.2 | CEE 25CEE 26XcelES CC | 5 | 214655290 |
| MOE31U-36HFN1-MECO-AIR · MOE Serieswith ducted air handler MAC-36HWDN1-MN0 | 3 tons35,000 Btu/h · Ducted | 2.00 | 82% | 10.0 | 15.2 | CEE 25CEE 26XcelES CC | 5 | 214655289 |
| MOD30U-30HFN1-MR0(X)ECO-AIR · MOD Serieswith ducted air handler MAC-36HWDN1-MN0 | 2.5 tons30,000 Btu/h · Ducted | 1.85 | 82% | 9.7 | 15.5 | CEE 25CEE 26XcelES CC | 6 | 214655288 |
| MOX630-36HFN1-M3XECO-AIR · MOX Serieswith ducted air handler MAC-36HWFN1-M | 3 tons35,000 Btu/h · Ducted | 1.80 | 83% | 8.5 | 15.2 | CEE 25CEE 26XcelES CC | 4 | 214442632 |
| MOD30-24HFN1-MWECO-AIR · MOD Serieswith ducted air handler MVBM-24A18T3N1 | 2 tons24,000 Btu/h · Ducted | 2.00 | 80% | 9.8 | 16.1 | CEE 25CEE 26XcelES CC | 4 | 213386479 |
Compare ECO-AIR