Endura heat pumps: how do their ratings compare?
A typical Endura heat pump beats 50% of similar heat pumps (same size and type), which is about average. Endura has 4 heat pump models in this list.
Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated
Overall score
50%
of similar heat pumps beaten by its typical model
About averageEndura has no QMID (the manufacturer ID the 25C tax credit needs) on file, so it is not ranked against other brands. Based on 4 models with every rating.
- Efficiency on a 5°F dayCOP at 5°FBeats 34%
- Heating power kept at 5°FCapacity at 5°F vs 47°FBeats 64%
- Winter-long heating efficiencyHSPF2Beats 51%
- Summer-long cooling efficiencySEER2Beats 48%
- Hot-day cooling efficiencyEER2Beats 52%
Average (50%)
Each bar: the share of similar heat pumps a typical model beats on that rating.
Want Endura’s ranks and its models inside every size class? Switch to Advanced
Rebate standards
50%
meet CEE 2025 Tier 1, the level many utility rebates use.
2 models. All brands: 48%.
75%
meet Xcel Energy Colorado’s cold-climate rebate levels.
3 models. All brands: 38%.
0%
reach the cold-climate tier: full heating output and a COP of 2.1 or more at 5°F.
None of its models yet. All brands: 1%.
Endura all-around best, by size
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Showing Ductless, Up to 1.5 tons (under 21,000 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?
2 of Endura’s 2 models of this size and type have all five ratings.
- 1HBEFL-OD12with ductless indoor unit HBEFL-ID12Endura1 ton · 12,000 Btu/h · DuctlessCold-climate pick, score 58.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 83% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.89 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.5 (HSPF2)
- Good
- Cooling efficiency
- 23.5 (SEER2)
- Great
- Hot-day cooling
- 12.7 (EER2)
- Good
- 2HBEFL-OD18with ductless indoor unit HBEFL- ID18Endura1.5 tons · 18,000 Btu/h · DuctlessCold-climate pick, score 51.4Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 86% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 9.5 (HSPF2)
- Good
- Cooling efficiency
- 20.5 (SEER2)
- Below the middle
- Hot-day cooling
- 13.2 (EER2)
- Great
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
What to do next
The advanced view has Endura’s ranks on each rating, its models inside every size and type, cold-weather curves and its newest certifications.
Open the advanced view