- Insights
- Manufacturers
- Friedrich
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Friedrich heat pump efficiency: 117 outdoor models compared
Friedrich has 117 heat pump outdoor models certified with this refrigerant group, in 3,083 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Friedrich makes. Ranks are among manufacturers with a QMID on file and at least 10 scored models.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 117
- AHRI certifications
- 3,083
- Efficiency index
- 46%
- Typical model vs same-size, same-type peers (84 models)
- Meet CEE 2025
- 37.6%
- 44 models
How Friedrich compares with comparable models
- Friedrich
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index84 models scored | 46% | 25th of 27 | — |
| COP at 5°F84 models scored | 58% | 9th of 27 | 2.10 |
| Capacity retention at 5°F84 models scored | 45% | 20th of 27 | 61% |
| HSPF2124 models scored | 31% | 26th of 27 | 7.5 |
| SEER2124 models scored | 36% | 26th of 27 | 15.2 |
| EER2124 models scored | 39% | 26th of 27 | 10.6 |
| Heating capacity at 5°F84 models scored | 39% | 25th of 27 | 15,600 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 37.6% | 44 |
| CEE 2026 Tier 1 (Split ASHP) | 37.6% | 44 |
| CEE Advanced Tier (Split ASHP) | 1.7% | 2 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 31.6% | 37 |
| DOE Cold Climate Heat Pump Challenge | 1.7% | 2 |
| ENERGY STAR Cold Climate | 28.2% | 33 |
Sizes and duct types offered
- Friedrich (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 21 | 27% | 45% | 16% | 22% |
| Ducted, 2 tons | 16 | 45% | 68% | 30% | 37% |
| Ducted, 2.5–3 tons | 22 | 52% | 83% | 29% | 33% |
| Ducted, 3.5–4.5 tons | 28 | 47% | 79% | 33% | 38% |
| Ducted, 5 tons and up | 7 | — | — | 16% | 24% |
| Non-ducted, up to 1.5 tons | 19 | 55% | 34% | 56% | 57% |
| Non-ducted, 2 tons | 6 | 47% | 30% | 40% | 50% |
| Non-ducted, 2.5–3 tons | 6 | 61% | 71% | 25% | 21% |
| Non-ducted, 3.5–4.5 tons | 1 | 45% | 41% | 14% | 45% |
Every Friedrich model in the market
- Friedrich models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top Friedrich models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1FRP18AZ36AJVCFRIEDRICH · K-SERIESwith indoor coil TCFZ3621MEAAM and furnace FR801V0504A17UHU | 3 tons34,200 Btu/h · Ducted | 121% | 2.20 | 8.5 | 43,500 | 19.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 23 | 213829722 | Ducted, 2.5–3 tons | 80.6 |
| 2FPHFR09A3AFRIEDRICH · Prowith ductless indoor unit FPHFC09A3B | 1 ton9,000 Btu/h · Non-ducted | 92% | 2.19 | 10.0 | 8,300 | 20.5 | CEE 25CEE 26XcelES CC | 2 | 205048197 | Non-ducted, up to 1.5 tons | 78.4 |
| 3FPHFR36A3AFRIEDRICH · Prowith ducted air handler FPHSD36A3A | 3 tons36,000 Btu/h · Ducted | 76% | 2.20 | 9.5 | 27,400 | 17.5 | CEE 25CEE 26Xcel | 2 | 205150422 | Ducted, 2.5–3 tons | 78.1 |
| 4FPHFR36A3AFRIEDRICH · Prowith ductless indoor unit FPHSC36A3B | 3 tons36,000 Btu/h · Non-ducted | 74% | 2.28 | 9.8 | 26,800 | 18.0 | CEE 25CEE 26Xcel | 2 | 205150421 | Non-ducted, 2.5–3 tons | 77.2 |
| 5FRP18AZ48AJVCFRIEDRICHwith indoor coil TCFZ6021SEAAM and furnace FR962V1005A21M4 | 3.5 tons44,500 Btu/h · Ducted | 103% | 2.00 | 8.5 | 45,000 | 19.0 | CEE 25CEE 26XcelES CC | 21 | 214279028 | Ducted, 3.5–4.5 tons | 76.3 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1FRP18AZ36AJVCFRIEDRICH · K-SERIESwith ducted air handler FRHMVZ6021SEACA | 3 tons34,200 Btu/h · Ducted | 113% | 2.10 | 8.5 | 20.0 | 12.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 23 | 213087287 | Ducted, 2.5–3 tons | 86.1 | 78.4 | 93.8 | 80.6 |
| 2MRH09Y3JAFRIEDRICHwith ductless indoor unit MWH09Y3JA | 1 ton9,000 Btu/h · Non-ducted | 78% | 2.10 | 10.5 | 27.5 | 15.5 | CEE 25CEE 26Xcel | 1 | 201763897 | Non-ducted, up to 1.5 tons | 85.1 | 75.0 | 95.1 | 75.0 |
| 3FRP18AZ24AJVCFRIEDRICH · K-SERIESwith indoor coil TCFZ2421HEAAM and furnace FR801V0504A17UHU | 2 tons22,800 Btu/h · Ducted | 108% | 2.10 | 8.5 | 20.0 | 12.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 21 | 213829710 | Ducted, 2 tons | 83.5 | 74.7 | 92.4 | 74.7 |
| 4FRP18AZ48AJVCFRIEDRICH · K-SERIESwith indoor coil TCFZ6021SEAAM and furnace FR802V1005A21UH | 3.5 tons44,500 Btu/h · Ducted | 94% | 2.00 | 8.5 | 19.0 | 11.7 | CEE 25CEE 26XcelES CC | 21 | 214610153 | Ducted, 3.5–4.5 tons | 80.3 | 75.1 | 85.4 | 76.3 |
| 5FPHMR36A3AFRIEDRICH · Pro | 2.5 tons32,000 Btu/h · Ducted | 113% | 1.84 | 8.9 | 19.5 | 12.0 | CEE 25CEE 26XcelES CC | 3 | 203996910 | Ducted, 2.5–3 tons | 78.6 | 69.2 | 88.0 | 69.2 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | WFPU17Z243C | 2.80 | Ducted, up to 1.5 tons | 97% | 214638706 |
| Capacity retention at 5°F | FRP18AZ48AJVC | 105% | Ducted, 3.5–4.5 tons | 100% | 214802163 |
| HSPF2 | FPHFR36A3A | 9.5 | Ducted, 2.5–3 tons | 83% | 205150422 |
| SEER2 | MRH09Y3JA | 27.5 | Non-ducted, up to 1.5 tons | 96% | 201763897 |
| EER2 | MRH09Y3JA | 15.5 | Non-ducted, up to 1.5 tons | 93% | 201763897 |
| Heating capacity at 5°F | FRP18AZ36AJVC | 43,500 Btu/h | Ducted, 2.5–3 tons | 100% | 213829722 |
Friedrich size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 55.9(50 is the typical model of its size class)FPHFR09A3Awith ducted air handler FPHFD09A3A4 of 20 models qualify · AHRI 205048198 | 57.7(50 is the typical model of its size class)FPHFR09A3Awith ducted air handler FPHFD09A3A14 of 20 models have all five ratings · AHRI 205048198 |
| Ducted, 2 tons | 74.7(50 is the typical model of its size class)FRP18AZ24AJVCwith indoor coil TCFZ2421HEAAM and furnace FR801V0504A17UHU5 of 17 models qualify · AHRI 213829710 | 83.5(50 is the typical model of its size class)FRP18AZ24AJVCwith indoor coil TCFZ2421HEAAM and furnace FR801V0504A17UHU12 of 17 models have all five ratings · AHRI 213829710 |
| Ducted, 2.5–3 tons | 80.6(50 is the typical model of its size class)FRP18AZ36AJVCwith indoor coil TCFZ3621MEAAM and furnace FR801V0504A17UHU5 of 22 models qualify · AHRI 213829722 | 86.1(50 is the typical model of its size class)FRP18AZ36AJVCwith ducted air handler FRHMVZ6021SEACA12 of 22 models have all five ratings · AHRI 213087287 |
| Ducted, 3.5–4.5 tons | 76.3(50 is the typical model of its size class)FRP18AZ48AJVCwith indoor coil TCFZ6021SEAAM and furnace FR962V1005A21M47 of 28 models qualify · AHRI 214279028 | 80.3(50 is the typical model of its size class)FRP18AZ48AJVCwith indoor coil TCFZ6021SEAAM and furnace FR802V1005A21UH17 of 27 models have all five ratings · AHRI 214610153 |
| Ducted, 5 tons and up | None on this board (0 of 7 models qualify) | 70.1(50 is the typical model of its size class)FWP15AZ60AJ2Nwith indoor coil TCFZ6024STANM and furnace FR97MV1005A21DH1 of 8 models have all five ratings · AHRI 213841738 |
| Non-ducted, up to 1.5 tons | 78.4(50 is the typical model of its size class)FPHFR09A3Awith ductless indoor unit FPHFC09A3B18 of 19 models qualify · AHRI 205048197 | 85.1(50 is the typical model of its size class)MRH09Y3JAwith ductless indoor unit MWH09Y3JA19 of 19 models have all five ratings · AHRI 201763897 |
| Non-ducted, 2 tons | 72.0(50 is the typical model of its size class)FPHFR24A3Awith ductless indoor unit FPHFC24A3B5 of 6 models qualify · AHRI 205123805 | 67.5(50 is the typical model of its size class)FPHMR24A3A6 of 6 models have all five ratings · AHRI 204101246 |
| Non-ducted, 2.5–3 tons | 77.2(50 is the typical model of its size class)FPHFR36A3Awith ductless indoor unit FPHSC36A3B2 of 6 models qualify · AHRI 205150421 | 69.4(50 is the typical model of its size class)FPHMR36A3A2 of 6 models have all five ratings · AHRI 204101247 |
| Non-ducted, 3.5–4.5 tons | 41.9(50 is the typical model of its size class)FPHMR42A3A1 of 1 models qualify · AHRI 205141513 | 44.5(50 is the typical model of its size class)FPHMR42A3A1 of 1 models have all five ratings · AHRI 205141512 |
Newest Friedrich certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| WFPU18Z363CFRIEDRICHwith ducted air handler PL36H***P449+TD | 2.5 tons29,400 Btu/h · Ducted | 2.08 | 66% | 9.4 | 15.2 | CEE 25CEE 26XcelES CC | 55 | 216619375 |
| WFPU18Z483CFRIEDRICHwith ducted air handler H,RG86960+AEFE5 | 4 tons47,500 Btu/h · Ducted | 1.90 | 68% | 8.5 | 17.0 | CEE 25CEE 26XcelES CC | 49 | 216619286 |
| WFPU17Z243CFRIEDRICHwith ducted air handler H,RG33936+AEFE3A | 2 tons21,600 Btu/h · Ducted | 2.02 | 69% | 8.9 | 16.0 | CEE 25CEE 26XcelES CC | 64 | 216619283 |
| WFPU17Z603CFRIEDRICHwith ducted air handler H,GE50960+AEFE5 | 4.5 tons55,000 Btu/h · Ducted | — | — | 8.4 | 16.0 | None | 22 | 216618737 |
| RD17AZ24AJ3NFRIEDRICHwith ducted air handler L(E,F)W30D4 | 2 tons21,000 Btu/h · Ducted | 2.20 | 68% | 7.5 | 14.3 | CEE 25CEE 26XcelES CC | 108 | 215912492 |
Compare Friedrich