Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
GCHV heat pump efficiency: 18 outdoor models compared
GCHV has 18 heat pump outdoor models certified with this refrigerant group, in 34 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes GCHV makes. GCHV has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 18
- AHRI certifications
- 34
- Efficiency index
- 54%
- Typical model vs same-size, same-type peers (1 model)
- Meet CEE 2025
- 0%
- 0 models
How GCHV compares with comparable models
- GCHV
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index1 model scored | 54% | Not ranked | — |
| COP at 5°F1 model scored | 44% | Not ranked | 1.85 |
| Capacity retention at 5°F1 model scored | 65% | Not ranked | 76% |
| HSPF218 models scored | 32% | Not ranked | 7.6 |
| SEER218 models scored | 48% | Not ranked | 16.0 |
| EER218 models scored | 49% | Not ranked | 11.4 |
| Heating capacity at 5°F1 model scored | 45% | Not ranked | 21,600 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0% | 0 |
| CEE 2026 Tier 1 (Split ASHP) | 0% | 0 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 5.6% | 1 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- GCHV (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 1 | — | — | 12% | 10% |
| Ducted, 2 tons | 4 | — | — | 38% | 52% |
| Ducted, 2.5–3 tons | 6 | 54% | 44% | 32% | 50% |
| Ducted, 3.5–4.5 tons | 7 | — | — | 31% | 50% |
Every GCHV model in the market
- GCHV models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top GCHV models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1COU-D30HNR1-D01-J0GCHVwith ducted air handler CAHI-36HNVR1-18 | 2.5 tons30,000 Btu/h · Ducted | 76% | 1.85 | 7.8 | 21,600 | 17.5 | Xcel | 3 | 207743797 | Ducted, 2.5–3 tons | 48.2 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1COU-D30HNR1-D01-J0GCHVwith ducted air handler CAHI-36HNVR1-18 | 2.5 tons30,000 Btu/h · Ducted | 76% | 1.85 | 7.8 | 17.5 | 11.0 | Xcel | 3 | 207743797 | Ducted, 2.5–3 tons | 54.4 | 48.2 | 60.5 | 48.2 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | COU-D30HNR1-D01-J0 | 1.85 | Ducted, 2.5–3 tons | 44% | 207743797 |
| Capacity retention at 5°F | COU-D30HNR1-D01-J0 | 76% | Ducted, 2.5–3 tons | 62% | 212920647 |
| HSPF2 | COT-60HNVR1-18 | 8.2 | Ducted, 3.5–4.5 tons | 55% | 213386557 |
| SEER2 | CRB-DD48HNR1-WKB2-H0 | 16.7 | Ducted, 3.5–4.5 tons | 74% | 214723194 |
| EER2 | COT-24HNVR1-18 | 12.2 | Ducted, 2 tons | 76% | 206261153 |
| Heating capacity at 5°F | COU-D30HNR1-D01-J0 | 22,400 Btu/h | Ducted, 2.5–3 tons | 45% | 212920647 |
GCHV size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 1 models qualify) | None on this board (0 of 1 models have all five ratings) |
| Ducted, 2 tons | None on this board (0 of 4 models qualify) | None on this board (0 of 4 models have all five ratings) |
| Ducted, 2.5–3 tons | 48.2(50 is the typical model of its size class)COU-D30HNR1-D01-J0with ducted air handler CAHI-36HNVR1-181 of 6 models qualify · AHRI 207743797 | 54.4(50 is the typical model of its size class)COU-D30HNR1-D01-J0with ducted air handler CAHI-36HNVR1-181 of 6 models have all five ratings · AHRI 207743797 |
| Ducted, 3.5–4.5 tons | None on this board (0 of 7 models qualify) | None on this board (0 of 7 models have all five ratings) |
Newest GCHV certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| COT-F48HGR1-60-E3(S)GCHVwith ducted air handler CAHI-60CNVR1-18 | 4 tons45,500 Btu/h · Ducted | — | — | 7.5 | 14.3 | None | 3 | 217596939 |
| COT-F24HGR1-45-E3(S)GCHVwith ducted air handler CAHI-24CNVR1-18 | 2 tons23,200 Btu/h · Ducted | — | — | 7.8 | 15.2 | None | 4 | 217596937 |
| COT-F30HGR1-45-E3(S)GCHVwith ducted air handler CAH-F36CGR1-FQB-E3 | 2.5 tons28,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | None | 4 | 217110149 |
| COT-F18HGR1-40-E3(S)GCHVwith ducted air handler CAH-F24CGR1-FQA-E3 | 1.5 tons17,600 Btu/h · Ducted | — | — | 7.5 | 14.3 | None | 3 | 217110148 |
| COT-F36HGR1-45-E3(S)GCHVwith ducted air handler CAH-F42CNR1-FMC-E3 | 3 tons33,000 Btu/h · Ducted | — | — | 7.7 | 14.3 | None | 3 | 217110147 |
Compare GCHV