GCHV heat pump efficiency: 20 outdoor models compared
GCHV has 20 heat pump outdoor models certified with this refrigerant group, in 48 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes GCHV makes. GCHV has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 20
- AHRI certifications
- 48
- Efficiency index
- 38%
- Typical model vs same-size, same-type peers (9 models)
- Meet CEE 2025
- 20%
- 4 models
How GCHV compares with comparable models
- GCHV
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index9 models scored | 38% | Not ranked | — |
| COP at 5°F9 models scored | 39% | Not ranked | 1.84 |
| Capacity retention at 5°F9 models scored | 37% | Not ranked | 70% |
| HSPF220 models scored | 28% | Not ranked | 7.5 |
| SEER220 models scored | 30% | Not ranked | 14.3 |
| EER220 models scored | 51% | Not ranked | 11.7 |
| Heating capacity at 5°F9 models scored | 45% | Not ranked | 11,100 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 20% | 4 |
| CEE 2026 Tier 1 (Split ASHP) | 20% | 4 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 20% | 4 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 10% | 2 |
Sizes and duct types offered
- GCHV (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 6 | 14% | 13% | 7% | 16% |
| Ducted, 2 tons | 5 | 57% | 52% | 37% | 41% |
| Ducted, 2.5–3 tons | 4 | — | — | 29% | 24% |
| Ducted, 3.5–4.5 tons | 5 | 59% | 69% | 45% | 42% |
Every GCHV model in the market
- GCHV models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top GCHV models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1COT-D36HNR8-EA01(J0)GCHV · COT-D36HNR8-EA01(J0)with ducted air handler CAH-D24HNR8-FMC(J0)Also listed as COT-D24HNR8-EA01(J0) | 2 tons24,000 Btu/h · Ducted | 83% | 2.10 | 9.4 | 20,000 | 20.0 | CEE 25CEE 26XcelES CC | 2 | 215223218 | Ducted, 2 tons | 67.2 |
| 2COT-D60HNR8-GA01(J0)GCHV · COT-D60HNR8-GA01(J0)with ducted air handler CAH-D60HNR8-FMD(J0)Also listed as COT-D48HNR8-GA01(J0) | 4.5 tons55,500 Btu/h · Ducted | 75% | 2.10 | 8.6 | 42,500 | 17.0 | CEE 25CEE 26XcelES CC | 2 | 215223221 | Ducted, 3.5–4.5 tons | 64.7 |
| 3CPT-DD09AGR4-VTAGCHV | 1 ton9,600 Btu/h · Ducted | 70% | 1.61 | 6.6 | 6,900 | 13.8 | None | 1 | 218724431 | Ducted, up to 1.5 tons | 8.8 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1COT-D36HNR8-EA01(J0)GCHV · COT-D36HNR8-EA01(J0)with ducted air handler CAH-D24HNR8-FMC(J0)Also listed as COT-D24HNR8-EA01(J0) | 2 tons24,000 Btu/h · Ducted | 83% | 2.10 | 9.4 | 20.0 | 13.3 | CEE 25CEE 26XcelES CC | 2 | 215223218 | Ducted, 2 tons | 79.6 | 67.2 | 92.1 | 67.2 |
| 2COT-D60HNR8-GA01(J0)GCHV · COT-D60HNR8-GA01(J0)with ducted air handler CAH-D48HNR8-FMD(J0) | 4 tons47,500 Btu/h · Ducted | 71% | 2.10 | 9.0 | 17.5 | 11.3 | CEE 25CEE 26XcelES CC | 2 | 215223220 | Ducted, 3.5–4.5 tons | 64.4 | 63.9 | 64.9 | 64.7 |
| 3COT-D48HNR8-GA01(J0)GCHVwith ducted air handler CAH-D60HNR8-FMD(J0) | 4.5 tons55,500 Btu/h · Ducted | 75% | 2.10 | 8.6 | 17.0 | 10.0 | CEE 25CEE 26Xcel | 1 | 217194699 | Ducted, 3.5–4.5 tons | 54.1 | 64.7 | 43.4 | 64.7 |
| 4CPT-DD12AGR4-VTAGCHV | 1 ton12,600 Btu/h · Ducted | 56% | 1.61 | 6.5 | 14.4 | 11.1 | None | 1 | 217175307 | Ducted, up to 1.5 tons | 18.3 | 5.2 | 31.4 | Not a pick |
| 5CPT-DD09AGR4-VTAGCHV | 1 ton9,600 Btu/h · Ducted | 70% | 1.61 | 6.6 | 13.8 | 11.0 | None | 1 | 218724431 | Ducted, up to 1.5 tons | 14.1 | 8.8 | 19.4 | 8.8 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | COT-D60HNR8-GA01(J0) | 2.10 | Ducted, 3.5–4.5 tons | 69% | 215223220 |
| Capacity retention at 5°F | COT-D36HNR8-EA01(J0)Also listed as COT-D24HNR8-EA01(J0) | 83% | Ducted, 2 tons | 66% | 215223218 |
| HSPF2 | COT-D60HNR8-GA01(J0) | 9.0 | Ducted, 3.5–4.5 tons | 69% | 215223220 |
| SEER2 | COT-D36HNR8-EA01(J0)Also listed as COT-D24HNR8-EA01(J0) | 20.0 | Ducted, 2 tons | 87% | 215223218 |
| EER2 | COT-D36HNR8-EA01(J0)Also listed as COT-D24HNR8-EA01(J0) | 13.3 | Ducted, 2 tons | 93% | 215223218 |
| Heating capacity at 5°F | COT-D60HNR8-GA01(J0)Also listed as COT-D48HNR8-GA01(J0) | 42,500 Btu/h | Ducted, 3.5–4.5 tons | 74% | 215223221 |
GCHV size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 8.8(50 is the typical model of its size class)CPT-DD09AGR4-VTA1 of 6 models qualify · AHRI 218724431 | 18.3(50 is the typical model of its size class)CPT-DD12AGR4-VTA4 of 6 models have all five ratings · AHRI 217175307 |
| Ducted, 2 tons | 67.2(50 is the typical model of its size class)COT-D36HNR8-EA01(J0)with ducted air handler CAH-D24HNR8-FMC(J0)Also listed as COT-D24HNR8-EA01(J0)2 of 5 models qualify · AHRI 215223218 | 79.6(50 is the typical model of its size class)COT-D36HNR8-EA01(J0)with ducted air handler CAH-D24HNR8-FMC(J0)Also listed as COT-D24HNR8-EA01(J0)3 of 5 models have all five ratings · AHRI 215223218 |
| Ducted, 2.5–3 tons | None on this board (0 of 4 models qualify) | None on this board (0 of 4 models have all five ratings) |
| Ducted, 3.5–4.5 tons | 64.7(50 is the typical model of its size class)COT-D60HNR8-GA01(J0)with ducted air handler CAH-D60HNR8-FMD(J0)Also listed as COT-D48HNR8-GA01(J0)2 of 5 models qualify · AHRI 215223221 | 64.4(50 is the typical model of its size class)COT-D60HNR8-GA01(J0)with ducted air handler CAH-D48HNR8-FMD(J0)2 of 5 models have all five ratings · AHRI 215223220 |
Newest GCHV certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| CPT-DD24AGR4-VPAGCHV | 2 tons22,000 Btu/h · Ducted | 1.84 | 55% | 7.1 | 12.8 | None | 1 | 218724433 |
| CPT-DD15AGR4-VTAGCHV | 1.5 tons15,000 Btu/h · Ducted | 1.67 | 50% | 6.4 | 13.7 | None | 1 | 218724432 |
| CPT-DD09AGR4-VTAGCHV | 1 ton9,600 Btu/h · Ducted | 1.61 | 70% | 6.6 | 13.8 | None | 1 | 218724431 |
| COT-F36HNR8-EA02(E3)GCHVwith ducted air handler CAH-F30HNR8-FQB(E3-2) | 3 tons33,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | None | 4 | 218029225 |
| COT-F30HNR8-EA02(E3)GCHVwith ducted air handler CAH-F36HNR8-FQB(E3-1) | 2.5 tons27,400 Btu/h · Ducted | — | — | 7.5 | 14.3 | None | 4 | 218029224 |
Compare GCHV
GCHV includes these brand names as listed in AHRI: GCHV. Standards are checked against published thresholds; program rules beyond ratings are not checked.