Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
APLUS heat pump efficiency: 31 outdoor models compared
APLUS has 31 heat pump outdoor models certified with this refrigerant group, in 62 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes APLUS makes. APLUS has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 31
- AHRI certifications
- 62
- Efficiency index
- 17%
- Typical model vs same-size, same-type peers (5 models)
- Meet CEE 2025
- 0%
- 0 models
How APLUS compares with comparable models
- APLUS
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index5 models scored | 17% | Not ranked | — |
| COP at 5°F5 models scored | 14% | Not ranked | 1.64 |
| Capacity retention at 5°F5 models scored | 6% | Not ranked | 38% |
| HSPF231 models scored | 23% | Not ranked | 7.5 |
| SEER231 models scored | 22% | Not ranked | 14.3 |
| EER231 models scored | 50% | Not ranked | 11.7 |
| Heating capacity at 5°F5 models scored | 7% | Not ranked | 11,800 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0% | 0 |
| CEE 2026 Tier 1 (Split ASHP) | 0% | 0 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0% | 0 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- APLUS (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 3 | — | — | 14% | 22% |
| Ducted, 2 tons | 7 | 8% | 2% | 19% | 17% |
| Ducted, 2.5–3 tons | 13 | 17% | 12% | 24% | 21% |
| Ducted, 3.5–4.5 tons | 8 | 24% | 34% | 27% | 29% |
Every APLUS model in the market
- APLUS models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top APLUS models
Cold-climate picks
No APLUS model keeps at least 70% of its heat at 5°F with all three cold-climate ratings.
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ART-HF48SSMR3-C01/SE134APLUS | 3.5 tons44,500 Btu/h · Ducted | 41% | 1.86 | 6.7 | 13.4 | 11.2 | None | 1 | 218725506 | Ducted, 3.5–4.5 tons | 24.4 | 17.3 | 31.5 | Not a pick |
| 2ART-HF42SSMR3-C01/SE134APLUS | 3 tons38,500 Btu/h · Ducted | 43% | 1.86 | 6.7 | 13.4 | 11.4 | None | 1 | 218725505 | Ducted, 2.5–3 tons | 20.9 | 15.4 | 26.5 | Not a pick |
| 3ART-HF30SSMR3-D01/SE134APLUS | 2.5 tons28,200 Btu/h · Ducted | 38% | 1.64 | 6.7 | 13.4 | 11.5 | None | 1 | 218725503 | Ducted, 2.5–3 tons | 17.0 | 5.4 | 28.6 | Not a pick |
| 4ART-HF36SSMR3-D01/SE134APLUS | 2.5 tons32,000 Btu/h · Ducted | 37% | 1.58 | 6.7 | 13.4 | 11.2 | None | 1 | 218725504 | Ducted, 2.5–3 tons | 14.3 | 4.1 | 24.5 | Not a pick |
| 5ART-HF24SSMR3-D01/SE134APLUS | 2 tons22,800 Btu/h · Ducted | 37% | 1.48 | 6.7 | 13.4 | 10.8 | None | 1 | 218725502 | Ducted, 2 tons | 8.4 | 3.7 | 13.0 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | ART-HF48SSMR3-C01/SE134 | 1.86 | Ducted, 3.5–4.5 tons | 34% | 218725506 |
| Capacity retention at 5°F | ART-HF42SSMR3-C01/SE134 | 43% | Ducted, 2.5–3 tons | 13% | 218725505 |
| HSPF2 | ATD-HF42SMR4-C01/SE143 | 7.5 | Ducted, 3.5–4.5 tons | 27% | 217037886 |
| SEER2 | ART-HF48DDMR3-C01/SE160 | 16.0 | Ducted, 3.5–4.5 tons | 50% | 218338174 |
| EER2 | ATD-HF42SMR4-C01/SE143 | 11.7 | Ducted, 3.5–4.5 tons | 67% | 217037886 |
| Heating capacity at 5°F | ART-HF42SSMR3-C01/SE134 | 16,200 Btu/h | Ducted, 2.5–3 tons | 19% | 218725505 |
APLUS size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 3 models qualify) | None on this board (0 of 3 models have all five ratings) |
| Ducted, 2 tons | None on this board (0 of 7 models qualify) | 8.4(50 is the typical model of its size class)ART-HF24SSMR3-D01/SE1341 of 7 models have all five ratings · AHRI 218725502 |
| Ducted, 2.5–3 tons | None on this board (0 of 13 models qualify) | 20.9(50 is the typical model of its size class)ART-HF42SSMR3-C01/SE1343 of 13 models have all five ratings · AHRI 218725505 |
| Ducted, 3.5–4.5 tons | None on this board (0 of 8 models qualify) | 24.4(50 is the typical model of its size class)ART-HF48SSMR3-C01/SE1341 of 8 models have all five ratings · AHRI 218725506 |
Newest APLUS certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| ART-HF48SSMR3-C01/SE134APLUS | 3.5 tons44,500 Btu/h · Ducted | 1.86 | 41% | 6.7 | 13.4 | None | 1 | 218725506 |
| ART-HF42SSMR3-C01/SE134APLUS | 3 tons38,500 Btu/h · Ducted | 1.86 | 43% | 6.7 | 13.4 | None | 1 | 218725505 |
| ART-HF36SSMR3-D01/SE134APLUS | 2.5 tons32,000 Btu/h · Ducted | 1.58 | 37% | 6.7 | 13.4 | None | 1 | 218725504 |
| ART-HF30SSMR3-D01/SE134APLUS | 2.5 tons28,200 Btu/h · Ducted | 1.64 | 38% | 6.7 | 13.4 | None | 1 | 218725503 |
| ART-HF24SSMR3-D01/SE134APLUS | 2 tons22,800 Btu/h · Ducted | 1.48 | 37% | 6.7 | 13.4 | None | 1 | 218725502 |
Compare APLUS