Bravo vs GCHV heat pumps
Measured against models of the same size and duct type, Bravo scores higher on 4 of the 6 ratings. Bravo has 20 outdoor models, GCHV has 20 outdoor models. Bravo and GCHV have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Bravo
- GCHV
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Bravo | GCHV |
|---|---|---|
| Efficiency index | 45% (higher)median — | 38% (higher)median — |
| COP at 5°F | 42% (higher)median 1.90 | 39% (higher)median 1.84 |
| Capacity retention at 5°F | 39% (higher)median 64% | 37% (higher)median 70% |
| HSPF2 | 54% (higher)median 9.5 | 28% (higher)median 7.5 |
| SEER2 | 52% (higher)median 17.9 | 30% (higher)median 14.3 |
| EER2 | 40%median 10.5 | 52%median 11.7 |
| Heating capacity at 5°F | 40%median 16,250 Btu/h | 46%median 11,100 Btu/h |
| Outdoor models | 20 | 20 |
| AHRI certifications | 34 | 48 |
Share of models meeting each standard
| Standard | Bravo | GCHV |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 50%10 models | 20%4 models |
| CEE 2026 Tier 1 (Split ASHP) | 50%10 models | 20%4 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 40%8 models | 20%4 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 15%3 models | 10%2 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Bravo
- GCHV
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Bravo | GCHV |
|---|---|---|
| Ducted, up to 1.5 tons | 2 · index 51% | 6 · index 14% |
| Ducted, 2 tons | 2 · index 48% | 5 · index 57% |
| Ducted, 2.5 to 3 tons | 4 · index 58% | 4 · index — |
| Ducted, 3.5 to 4.5 tons | 3 · index 51% | 5 · index 60% |
| Non-ducted, up to 1.5 tons | 7 · index 33% | None |
| Non-ducted, 2 tons | 3 · index 40% | None |
| Non-ducted, 2.5 to 3 tons | 3 · index 42% | None |
| Non-ducted, 3.5 to 4.5 tons | 1 · index 75% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | BravoCold-climate score, best model | GCHVCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 56.5(50 is the typical model of its size class) (higher)BRV-M18-230VO1 of 2 models qualify · AHRI 217221457 | 9.7(50 is the typical model of its size class)CPT-DD09AGR4-VTA1 of 6 models qualify · AHRI 218724431 |
| Ducted, 2 tons | 59.1(50 is the typical model of its size class)BRV-M24-230VO1 of 2 models qualify · AHRI 217221458 | 66.8(50 is the typical model of its size class) (higher)COT-D36HNR8-EA01(J0)with ducted air handler CAH-D24HNR8-FMC(J0)Also listed as COT-D24HNR8-EA01(J0)2 of 5 models qualify · AHRI 215223218 |
| Ducted, 2.5 to 3 tons | 73.7(50 is the typical model of its size class)BRV-M30-230VO2 of 4 models qualify · AHRI 217221459 | None on this board (0 of 4 models qualify) |
| Ducted, 3.5 to 4.5 tons | 77.1(50 is the typical model of its size class) (higher)BRV-M42-230VO1 of 3 models qualify · AHRI 217221461 | 64.7(50 is the typical model of its size class)COT-D60HNR8-GA01(J0)with ducted air handler CAH-D60HNR8-FMD(J0)Also listed as COT-D48HNR8-GA01(J0)2 of 5 models qualify · AHRI 215223221 |
| Non-ducted, up to 1.5 tons | 66.2(50 is the typical model of its size class)BRV-M18-230VO3 of 7 models qualify · AHRI 217221452 | No models in this size class |
| Non-ducted, 2 tons | 68.5(50 is the typical model of its size class)BRV-M24-230VO2 of 3 models qualify · AHRI 217221453 | No models in this size class |
| Non-ducted, 2.5 to 3 tons | 63.1(50 is the typical model of its size class)BRV-M30-230VO2 of 3 models qualify · AHRI 217221464 | No models in this size class |
| Non-ducted, 3.5 to 4.5 tons | 60.3(50 is the typical model of its size class)BRV-M42-230VO1 of 1 models qualify · AHRI 217221466 | No models in this size class |
All-around best
| Size and duct type | BravoAll-around score, best model | GCHVAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 62.0(50 is the typical model of its size class) (higher)BRV-M18-230VO2 of 2 models have all five ratings · AHRI 217221457 | 19.1(50 is the typical model of its size class)CPT-DD12AGR4-VTA4 of 6 models have all five ratings · AHRI 217175307 |
| Ducted, 2 tons | 66.1(50 is the typical model of its size class)BRV-M24-230VO2 of 2 models have all five ratings · AHRI 217221458 | 79.5(50 is the typical model of its size class) (higher)COT-D36HNR8-EA01(J0)with ducted air handler CAH-D24HNR8-FMC(J0)Also listed as COT-D24HNR8-EA01(J0)3 of 5 models have all five ratings · AHRI 215223218 |
| Ducted, 2.5 to 3 tons | 80.8(50 is the typical model of its size class)BRV-M30-230VO4 of 4 models have all five ratings · AHRI 217221459 | None on this board (0 of 4 models have all five ratings) |
| Ducted, 3.5 to 4.5 tons | 87.2(50 is the typical model of its size class) (higher)BRV-M42-230VO3 of 3 models have all five ratings · AHRI 217221461 | 65.3(50 is the typical model of its size class)COT-D60HNR8-GA01(J0)with ducted air handler CAH-D48HNR8-FMD(J0)2 of 5 models have all five ratings · AHRI 215223220 |
| Non-ducted, up to 1.5 tons | 63.6(50 is the typical model of its size class)BRV-P09LS-230VOwith ductless indoor unit BRV-P09CT-230VI7 of 7 models have all five ratings · AHRI 218425279 | No models in this size class |
| Non-ducted, 2 tons | 73.3(50 is the typical model of its size class)BRV-M24-230VO3 of 3 models have all five ratings · AHRI 217221453 | No models in this size class |
| Non-ducted, 2.5 to 3 tons | 67.4(50 is the typical model of its size class)BRV-M30-230VO3 of 3 models have all five ratings · AHRI 217221454 | No models in this size class |
| Non-ducted, 3.5 to 4.5 tons | 74.5(50 is the typical model of its size class)BRV-M42-230VO1 of 1 models have all five ratings · AHRI 217221466 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Bravo | GCHV |
|---|---|---|
| COP at 5°F | beats 82% · 2.05BRV-M30-230VONon-ducted, 2.5 to 3 tons | beats 69% · 2.10COT-D60HNR8-GA01(J0)Ducted, 3.5 to 4.5 tons |
| Capacity retention at 5°F | beats 81% · 90%BRV-M24-230VONon-ducted, 2 tons | beats 66% · 83%COT-D36HNR8-EA01(J0)Also listed as COT-D24HNR8-EA01(J0)Ducted, 2 tons |
| HSPF2 | beats 87% · 10.0BRV-M42-230VODucted, 3.5 to 4.5 tons | beats 69% · 9.0COT-D60HNR8-GA01(J0)Ducted, 3.5 to 4.5 tons |
| SEER2 | beats 100% · 22.0BRV-M42-230VODucted, 3.5 to 4.5 tons | beats 86% · 20.0COT-D36HNR8-EA01(J0)Also listed as COT-D24HNR8-EA01(J0)Ducted, 2 tons |
| EER2 | beats 91% · 12.3BRV-M42-230VODucted, 3.5 to 4.5 tons | beats 93% · 13.3COT-D36HNR8-EA01(J0)Also listed as COT-D24HNR8-EA01(J0)Ducted, 2 tons |
| Heating capacity at 5°F | beats 86% · 14,500 Btu/hBRV-M18-230VONon-ducted, up to 1.5 tons | beats 74% · 42,500 Btu/hCOT-D60HNR8-GA01(J0)Also listed as COT-D48HNR8-GA01(J0)Ducted, 3.5 to 4.5 tons |