Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
BRAVO heat pump efficiency: 14 outdoor models compared
BRAVO has 14 heat pump outdoor models certified with this refrigerant group, in 28 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes BRAVO makes. BRAVO has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 14
- AHRI certifications
- 28
- Efficiency index
- 47%
- Typical model vs same-size, same-type peers (19 models)
- Meet CEE 2025
- 57.1%
- 8 models
How BRAVO compares with comparable models
- BRAVO
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index19 models scored | 47% | Not ranked | — |
| COP at 5°F19 models scored | 48% | Not ranked | 1.90 |
| Capacity retention at 5°F19 models scored | 41% | Not ranked | 70% |
| HSPF219 models scored | 53% | Not ranked | 9.5 |
| SEER219 models scored | 51% | Not ranked | 19.5 |
| EER219 models scored | 44% | Not ranked | 10.8 |
| Heating capacity at 5°F19 models scored | 41% | Not ranked | 13,250 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 57.1% | 8 |
| CEE 2026 Tier 1 (Split ASHP) | 57.1% | 8 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 57.1% | 8 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 21.4% | 3 |
Sizes and duct types offered
- BRAVO (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 1 | 61% | 49% | 62% | 72% |
| Ducted, 2 tons | 1 | 66% | 51% | 72% | 91% |
| Ducted, 2.5–3 tons | 2 | 76% | 77% | 83% | 95% |
| Ducted, 3.5–4.5 tons | 1 | 87% | 69% | 87% | 100% |
| Non-ducted, up to 1.5 tons | 7 | 32% | 37% | 42% | 31% |
| Non-ducted, 2 tons | 3 | 38% | 34% | 53% | 32% |
| Non-ducted, 2.5–3 tons | 3 | 41% | 58% | 38% | 37% |
| Non-ducted, 3.5–4.5 tons | 1 | 74% | 66% | 60% | 89% |
Every BRAVO model in the market
- BRAVO models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top BRAVO models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1BRV-M42-230VOBRAVO · Multi-spilt series | 3.5 tons42,000 Btu/h · Ducted | 83% | 2.10 | 10.0 | 35,000 | 22.0 | CEE 25CEE 26Xcel | 3 | 217221461 | Ducted, 3.5–4.5 tons | 76.8 |
| 2BRV-M30-230VOBRAVO · Multi-spilt series | 2.5 tons30,000 Btu/h · Ducted | 77% | 2.10 | 9.5 | 23,000 | 20.0 | CEE 25CEE 26XcelES CC | 3 | 217221459 | Ducted, 2.5–3 tons | 73.8 |
| 3BRV-M36-230VOBRAVO · Multi-spilt series | 3 tons36,000 Btu/h · Ducted | 70% | 2.10 | 10.0 | 25,200 | 20.0 | CEE 25CEE 26XcelES CC | 3 | 217221460 | Ducted, 2.5–3 tons | 70.3 |
| 4BRV-M24-230VOBRAVO · Multi-spilt series | 2 tons24,000 Btu/h · Non-ducted | 90% | 2.00 | 10.0 | 21,600 | 23.0 | CEE 25CEE 26Xcel | 3 | 217221453 | Non-ducted, 2 tons | 67.5 |
| 5BRV-M18-230VOBRAVO · Multi-spilt series | 1.5 tons17,700 Btu/h · Non-ducted | 81% | 2.00 | 10.0 | 14,500 | 22.0 | CEE 25CEE 26XcelES CC | 3 | 217221452 | Non-ducted, up to 1.5 tons | 64.5 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1BRV-M42-230VOBRAVO · Multi-spilt series | 3.5 tons42,000 Btu/h · Ducted | 83% | 2.10 | 10.0 | 22.0 | 12.3 | CEE 25CEE 26Xcel | 3 | 217221461 | Ducted, 3.5–4.5 tons | 87.0 | 76.8 | 97.3 | 76.8 |
| 2BRV-M30-230VOBRAVO · Multi-spilt series | 2.5 tons30,000 Btu/h · Ducted | 77% | 2.10 | 9.5 | 20.0 | 12.0 | CEE 25CEE 26XcelES CC | 3 | 217221459 | Ducted, 2.5–3 tons | 80.7 | 73.8 | 87.7 | 73.8 |
| 3BRV-M42-230VOBRAVO · Multi-spilt series | 3.5 tons42,000 Btu/h · Non-ducted | 82% | 2.05 | 10.3 | 23.0 | 12.4 | CEE 25CEE 26Xcel | 3 | 217221466 | Non-ducted, 3.5–4.5 tons | 74.4 | 59.9 | 89.0 | 59.9 |
| 4BRV-M36-230VOBRAVO · Multi-spilt series | 3 tons36,000 Btu/h · Ducted | 70% | 2.10 | 10.0 | 20.0 | 11.6 | CEE 25CEE 26XcelES CC | 3 | 217221460 | Ducted, 2.5–3 tons | 72.2 | 70.3 | 74.0 | 70.3 |
| 5BRV-M24-230VOBRAVO · Multi-spilt series | 2 tons24,000 Btu/h · Non-ducted | 90% | 2.00 | 10.0 | 23.0 | 12.5 | CEE 25CEE 26Xcel | 3 | 217221453 | Non-ducted, 2 tons | 71.8 | 67.5 | 76.1 | 67.5 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | BRV-M30-230VO | 2.05 | Non-ducted, 2.5–3 tons | 83% | 217221464 |
| Capacity retention at 5°F | BRV-M24-230VO | 90% | Non-ducted, 2 tons | 79% | 217221453 |
| HSPF2 | BRV-M42-230VO | 10.0 | Ducted, 3.5–4.5 tons | 86% | 217221461 |
| SEER2 | BRV-M42-230VO | 22.0 | Ducted, 3.5–4.5 tons | 100% | 217221461 |
| EER2 | BRV-M42-230VO | 12.3 | Ducted, 3.5–4.5 tons | 91% | 217221461 |
| Heating capacity at 5°F | BRV-M18-230VO | 14,500 Btu/h | Non-ducted, up to 1.5 tons | 85% | 217221452 |
BRAVO size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 55.6(50 is the typical model of its size class)BRV-M18-230VO1 of 1 models qualify · AHRI 217221457 | 61.1(50 is the typical model of its size class)BRV-M18-230VO1 of 1 models have all five ratings · AHRI 217221457 |
| Ducted, 2 tons | 59.1(50 is the typical model of its size class)BRV-M24-230VO1 of 1 models qualify · AHRI 217221458 | 66.1(50 is the typical model of its size class)BRV-M24-230VO1 of 1 models have all five ratings · AHRI 217221458 |
| Ducted, 2.5–3 tons | 73.8(50 is the typical model of its size class)BRV-M30-230VO2 of 2 models qualify · AHRI 217221459 | 80.7(50 is the typical model of its size class)BRV-M30-230VO2 of 2 models have all five ratings · AHRI 217221459 |
| Ducted, 3.5–4.5 tons | 76.8(50 is the typical model of its size class)BRV-M42-230VO1 of 1 models qualify · AHRI 217221461 | 87.0(50 is the typical model of its size class)BRV-M42-230VO1 of 1 models have all five ratings · AHRI 217221461 |
| Non-ducted, up to 1.5 tons | 64.5(50 is the typical model of its size class)BRV-M18-230VO3 of 7 models qualify · AHRI 217221452 | 61.4(50 is the typical model of its size class)BRV-P09LS-230VOwith ductless indoor unit BRV-P09CT-230VI7 of 7 models have all five ratings · AHRI 218425279 |
| Non-ducted, 2 tons | 67.5(50 is the typical model of its size class)BRV-M24-230VO2 of 3 models qualify · AHRI 217221453 | 71.8(50 is the typical model of its size class)BRV-M24-230VO3 of 3 models have all five ratings · AHRI 217221453 |
| Non-ducted, 2.5–3 tons | 62.1(50 is the typical model of its size class)BRV-M30-230VO2 of 3 models qualify · AHRI 217221464 | 66.6(50 is the typical model of its size class)BRV-M30-230VO3 of 3 models have all five ratings · AHRI 217221454 |
| Non-ducted, 3.5–4.5 tons | 59.9(50 is the typical model of its size class)BRV-M42-230VO1 of 1 models qualify · AHRI 217221466 | 74.4(50 is the typical model of its size class)BRV-M42-230VO1 of 1 models have all five ratings · AHRI 217221466 |
Newest BRAVO certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| BRV-P24LS-230VOBravowith ductless indoor unit BRV-P24DT-230VI | 2 tons24,000 Btu/h · Non-ducted | 1.90 | 71% | 9.5 | 18.0 | CEE 25CEE 26Xcel | 2 | 218425286 |
| BRV-P18LS-230VOBravowith ductless indoor unit BRV-P18DT-230VI | 1.5 tons18,000 Btu/h · Non-ducted | 1.90 | 66% | 9.0 | 18.0 | None | 2 | 218425285 |
| BRV-P12LS-230VOBravowith ductless indoor unit BRV-P12DT-230VI | 1 ton12,000 Btu/h · Non-ducted | 1.90 | 69% | 9.5 | 20.0 | CEE 25CEE 26Xcel | 2 | 218425284 |
| BRV-P09LS-230VOBravowith ductless indoor unit BRV-P09DT-230VI | 1 ton9,000 Btu/h · Non-ducted | 1.90 | 86% | 9.5 | 20.0 | CEE 25CEE 26Xcel | 2 | 218425283 |
| BRV-M42-230VOBRAVO · Multi-spilt series | 3.5 tons42,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.05 | 82% | 10.3 | 23.0 | CEE 25CEE 26Xcel | 3 | 217221466 |
Compare BRAVO