- Insights
- Manufacturers
- hykolity
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
hykolity heat pump efficiency: 6 outdoor models compared
hykolity has 6 heat pump outdoor models certified with this refrigerant group, in 6 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes hykolity makes. hykolity has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 6
- AHRI certifications
- 6
- Efficiency index
- 23%
- Typical model vs same-size, same-type peers (6 models)
- Meet CEE 2025
- 66.7%
- 4 models
How hykolity compares with comparable models
- hykolity
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index6 models scored | 23% | Not ranked | — |
| COP at 5°F6 models scored | 19% | Not ranked | 1.80 |
| Capacity retention at 5°F6 models scored | 25% | Not ranked | 63% |
| HSPF26 models scored | 19% | Not ranked | 8.5 |
| SEER26 models scored | 30% | Not ranked | 19.0 |
| EER26 models scored | 22% | Not ranked | 10.0 |
| Heating capacity at 5°F6 models scored | 36% | Not ranked | 12,300 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 66.7% | 4 |
| CEE 2026 Tier 1 (Split ASHP) | 50% | 3 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 33.3% | 2 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- hykolity (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Non-ducted, up to 1.5 tons | 4 | 22% | 18% | 16% | 26% |
| Non-ducted, 2 tons | 1 | 25% | 26% | 22% | 37% |
| Non-ducted, 2.5–3 tons | 1 | 28% | 15% | 26% | 36% |
Every hykolity model in the market
- hykolity models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top hykolity models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ACA-2504hykolitywith ductless indoor unit ACA-2503 | 1 ton12,000 Btu/h · Non-ducted | 70% | 1.80 | 8.5 | 8,600 | 19.0 | CEE 25CEE 26Xcel | 1 | 214584768 | Non-ducted, up to 1.5 tons | 28.4 |
| 2ACA-2502hykolitywith ductless indoor unit ACA-2501 | 1 ton9,000 Btu/h · Non-ducted | 70% | 1.75 | 8.5 | 7,000 | 19.0 | CEE 25CEE 26Xcel | 1 | 214584767 | Non-ducted, up to 1.5 tons | 20.8 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ACA-2533hykolity | 2.5 tons27,000 Btu/h · Non-ducted | 59% | 1.80 | 8.5 | 19.0 | 10.0 | None | 1 | 217497282 | Non-ducted, 2.5–3 tons | 28.1 | 18.7 | 37.5 | Not a pick |
| 2ACA-2531hykolity | 1.5 tons18,000 Btu/h · Non-ducted | 65% | 1.80 | 8.5 | 20.0 | 11.0 | CEE 25CEE 26 | 1 | 217497281 | Non-ducted, up to 1.5 tons | 27.2 | 20.4 | 34.0 | Not a pick |
| 3ACA-2512hykolitywith ductless indoor unit ACA-2511 | 2 tons24,000 Btu/h · Non-ducted | 61% | 1.80 | 8.5 | 19.0 | 10.0 | CEE 25 | 1 | 217497283 | Non-ducted, 2 tons | 24.8 | 19.1 | 30.5 | Not a pick |
| 4ACA-2504hykolitywith ductless indoor unit ACA-2503 | 1 ton12,000 Btu/h · Non-ducted | 70% | 1.80 | 8.5 | 19.0 | 10.0 | CEE 25CEE 26Xcel | 1 | 214584768 | Non-ducted, up to 1.5 tons | 23.6 | 28.4 | 18.9 | 28.4 |
| 5ACA-2502hykolitywith ductless indoor unit ACA-2501 | 1 ton9,000 Btu/h · Non-ducted | 70% | 1.75 | 8.5 | 19.0 | 10.0 | CEE 25CEE 26Xcel | 1 | 214584767 | Non-ducted, up to 1.5 tons | 19.9 | 20.8 | 18.9 | 20.8 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | ACA-2512 | 1.80 | Non-ducted, 2 tons | 26% | 217497283 |
| Capacity retention at 5°F | ACA-2504 | 70% | Non-ducted, up to 1.5 tons | 46% | 214584768 |
| HSPF2 | ACA-2533 | 8.5 | Non-ducted, 2.5–3 tons | 25% | 217497282 |
| SEER2 | ACA-2533 | 19.0 | Non-ducted, 2.5–3 tons | 35% | 217497282 |
| EER2 | ACA-2533 | 10.0 | Non-ducted, 2.5–3 tons | 39% | 217497282 |
| Heating capacity at 5°F | ACA-2531 | 13,000 Btu/h | Non-ducted, up to 1.5 tons | 78% | 217497281 |
hykolity size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 28.4(50 is the typical model of its size class)ACA-2504with ductless indoor unit ACA-25032 of 4 models qualify · AHRI 214584768 | 27.2(50 is the typical model of its size class)ACA-25314 of 4 models have all five ratings · AHRI 217497281 |
| Non-ducted, 2 tons | None on this board (0 of 1 models qualify) | 24.8(50 is the typical model of its size class)ACA-2512with ductless indoor unit ACA-25111 of 1 models have all five ratings · AHRI 217497283 |
| Non-ducted, 2.5–3 tons | None on this board (0 of 1 models qualify) | 28.1(50 is the typical model of its size class)ACA-25331 of 1 models have all five ratings · AHRI 217497282 |
Newest hykolity certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| ACA-2512hykolitywith ductless indoor unit ACA-2511 | 2 tons24,000 Btu/h · Non-ducted | 1.80 | 61% | 8.5 | 19.0 | CEE 25 | 1 | 217497283 |
| ACA-2533hykolity | 2.5 tons27,000 Btu/h · Non-ducted | 1.80 | 59% | 8.5 | 19.0 | None | 1 | 217497282 |
| ACA-2531hykolity | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 65% | 8.5 | 20.0 | CEE 25CEE 26 | 1 | 217497281 |
| ACA-2508hykolitywith ductless indoor unit ACA-2507 | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 59% | 8.5 | 19.0 | None | 1 | 214584769 |
| ACA-2504hykolitywith ductless indoor unit ACA-2503 | 1 ton12,000 Btu/h · Non-ducted | 1.80 | 70% | 8.5 | 19.0 | CEE 25CEE 26Xcel | 1 | 214584768 |
Compare hykolity
hykolity includes these brand names as listed in AHRI: hykolity. Standards are checked against published thresholds; program rules beyond ratings are not checked.