Skip to content

hykolity heat pump efficiency: 7 outdoor models compared

hykolity has 7 heat pump outdoor models certified with this refrigerant group, in 7 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes hykolity makes. hykolity has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

Simple view, for homeowners: top picks by size and what each rating measures →

ManufacturerData as of updated · sources

Outdoor models
7
AHRI certifications
7
Efficiency index
36%
Typical model vs same-size, same-type peers (7 models)
Meet CEE 2025
57.1%
4 models

How hykolity compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
hykolity against every ranked manufacturerPeer scores, 0 to 100 · grey ticks: each ranked manufacturer · shaded: the middle half of hykolity’s own modelshykolity is strongest on HSPF2 (its typical model beats 55% of comparable models) and weakest on EER2 (23%).
  • hykolity
  • Middle half of its models
  • Other ranked manufacturers
hykolity

Source: AHRI Directory, NEEP · as of

Average peer percentile of hykolity’s models
RatingBeats comparable modelsRankRaw median
Efficiency index7 models scored36%Not ranked—
COP at 5°F7 models scored30%Not ranked1.80
Capacity retention at 5°F7 models scored36%Not ranked70%
HSPF27 models scored55%Not ranked9.5
SEER27 models scored39%Not ranked20.0
EER27 models scored23%Not ranked10.5
Heating capacity at 5°F7 models scored49%Not ranked12,000 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
hykolity’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th to 90th percentile line
  • hykolity (median, middle 50%, 10th to 90th)
  • All models of the group
Non-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Non-ducted, up to 1.5 tons536%29%60%41%
Non-ducted, 2 tons130%16%47%39%
Non-ducted, 2.5 to 3 tons140%53%38%33%

Every hykolity model in the market

hykolity’s 7 models with a known size and duct type, over the shape of the whole catalog.
hykolity models by size and ratingColoured: hykolity · grey shapes: all 15,936 models · lines: catalog medians by size
  • hykolity models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 7 hykolity models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 15,936 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8971.641.711.751.852.24
Ducted, 1 ton4631.801.862.002.412.44
Ducted, 1.5 tons1,0351.751.822.002.202.40
Ducted, 2 tons1,0731.751.862.002.182.30
Ducted, 2.5 tons1,1361.701.802.002.102.36
Ducted, 3 tons7361.801.902.002.102.42
Ducted, 3.5 tons8981.701.802.002.102.46
Ducted, 4 tons7691.801.852.002.122.39
Ducted, 4.5 tons7241.701.801.902.102.20
Ducted, 5 tons911.892.002.102.102.10
Non-ducted, 0.5 tons1,3821.751.801.902.002.21
Non-ducted, 1 ton1,6201.801.801.952.102.21
Non-ducted, 1.5 tons1,4831.801.802.002.102.28
Non-ducted, 2 tons8611.801.982.002.102.30
Non-ducted, 2.5 tons4541.801.882.002.002.21
Non-ducted, 3 tons5221.801.972.002.032.20
Non-ducted, 3.5 tons3042.002.002.002.052.10
Non-ducted, 4 tons2141.962.002.052.102.11
Non-ducted, 4.5 tons801.901.911.962.012.01
Non-ducted, 5 tons881.992.042.052.202.20

Source: AHRI Directory · as of

Top hykolity models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 4 hykolity cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1ACA-2537hykolity2.5 tons28,000 Btu/h · Non-ducted75%2.009.521,00020.0CEE 25CEE 26Xcel1218087607Non-ducted, 2.5 to 3 tons48.6
2ACA-2535hykolity1.5 tons20,000 Btu/h · Non-ducted70%2.009.514,00023.0CEE 25CEE 26Xcel1218087606Non-ducted, up to 1.5 tons46.3
3ACA-2514hykolitywith ductless indoor unit ACA-25131 ton9,000 Btu/h · Non-ducted80%1.809.58,00020.0CEE 25CEE 26Xcel1218087604Non-ducted, up to 1.5 tons43.9
4ACA-2516hykolitywith ductless indoor unit ACA-25151 ton12,000 Btu/h · Non-ducted73%1.8010.08,80020.0Xcel1218087605Non-ducted, up to 1.5 tons43.4

All-around best

Top 5 hykolity models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1ACA-2535hykolity1.5 tons20,000 Btu/h · Non-ducted70%2.009.523.011.2CEE 25CEE 26Xcel1218087606Non-ducted, up to 1.5 tons49.546.352.846.3
2ACA-2514hykolitywith ductless indoor unit ACA-25131 ton9,000 Btu/h · Non-ducted80%1.809.520.012.0CEE 25CEE 26Xcel1218087604Non-ducted, up to 1.5 tons42.043.940.143.9
3ACA-2537hykolity2.5 tons28,000 Btu/h · Non-ducted75%2.009.520.011.0CEE 25CEE 26Xcel1218087607Non-ducted, 2.5 to 3 tons40.148.631.648.6
4ACA-2516hykolitywith ductless indoor unit ACA-25151 ton12,000 Btu/h · Non-ducted73%1.8010.020.09.5Xcel1218087605Non-ducted, up to 1.5 tons32.243.421.043.4
5ACA-2520hykolitywith ductless indoor unit ACA-25192 tons24,000 Btu/h · Non-ducted67%1.809.520.010.5CEE 25CEE 261218087603Non-ducted, 2 tons29.928.831.0Not a pick

Best model on each rating

hykolity’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FACA-25352.00Non-ducted, up to 1.5 tons64%218087606
Capacity retention at 5°FACA-251480%Non-ducted, up to 1.5 tons63%218087604
HSPF2ACA-2518Also listed as ACA-2518Y10.0Non-ducted, up to 1.5 tons66%218087602
SEER2ACA-253523.0Non-ducted, up to 1.5 tons67%218087606
EER2ACA-251412.0Non-ducted, up to 1.5 tons47%218087604
Heating capacity at 5°FACA-253514,000 Btu/hNon-ducted, up to 1.5 tons84%218087606

All 7 hykolity models in Explore

hykolity size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
hykolity: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are kept)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Non-ducted, up to 1.5 tons46.3(50 is the typical model of its size class)ACA-25353 of 5 models qualify · AHRI 21808760649.5(50 is the typical model of its size class)ACA-25355 of 5 models have all five ratings · AHRI 218087606
Non-ducted, 2 tonsNone on this board (0 of 1 models qualify)29.9(50 is the typical model of its size class)ACA-2520with ductless indoor unit ACA-25191 of 1 models have all five ratings · AHRI 218087603
Non-ducted, 2.5 to 3 tons48.6(50 is the typical model of its size class)ACA-25371 of 1 models qualify · AHRI 21808760740.1(50 is the typical model of its size class)ACA-25371 of 1 models have all five ratings · AHRI 218087607

All-around board, every manufacturer

Newest hykolity certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified hykolity outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
ACA-2518Yhykolitywith ductless indoor unit ACA-2517Y1.5 tons18,000 Btu/h · Non-ducted1.8067%10.020.0None1218444724
ACA-2537hykolity2.5 tons28,000 Btu/h · Non-ducted2.0075%9.520.0CEE 25CEE 26Xcel1218087607
ACA-2535hykolity1.5 tons20,000 Btu/h · Non-ducted2.0070%9.523.0CEE 25CEE 26Xcel1218087606
ACA-2516hykolitywith ductless indoor unit ACA-25151 ton12,000 Btu/h · Non-ducted1.8073%10.020.0Xcel1218087605
ACA-2514hykolitywith ductless indoor unit ACA-25131 ton9,000 Btu/h · Non-ducted1.8080%9.520.0CEE 25CEE 26Xcel1218087604

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for hykolity in this group.

Compare hykolity

Manufacturers of a similar size, side by side.

hykolity includes these brand names as listed in AHRI: hykolity. Standards are checked against published thresholds; program rules beyond ratings are not checked.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter