- Insights
- Manufacturers
- Innovair
Both views use the same certified data. This device remembers your choice.
Innovair heat pump efficiency: 48 outdoor models compared
Innovair has 48 heat pump outdoor models certified with this refrigerant group, in 95 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Innovair makes. Ranks are among manufacturers with a QMID on file and at least 10 scored models.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 48
- AHRI certifications
- 95
- Efficiency index
- 50%
- Typical model vs same-size, same-type peers (47 models)
- Meet CEE 2025
- 50%
- 24 models
How Innovair compares with comparable models
- Innovair
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index47 models scored | 50% | 19th of 27 | — |
| COP at 5°F47 models scored | 45% | 23rd of 27 | 1.90 |
| Capacity retention at 5°F47 models scored | 58% | 10th of 27 | 75% |
| HSPF252 models scored | 49% | 16th of 27 | 8.7 |
| SEER252 models scored | 47% | 16th of 27 | 17.0 |
| EER252 models scored | 41% | 25th of 27 | 10.5 |
| Heating capacity at 5°F47 models scored | 59% | 7th of 27 | 19,400 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 50% | 24 |
| CEE 2026 Tier 1 (Split ASHP) | 45.8% | 22 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 43.8% | 21 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 47.9% | 23 |
Sizes and duct types offered
- Innovair (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 5 | 54% | 57% | 65% | 51% |
| Ducted, 2 tons | 5 | 63% | 61% | 74% | 63% |
| Ducted, 2.5 to 3 tons | 7 | 51% | 52% | 67% | 51% |
| Ducted, 3.5 to 4.5 tons | 6 | 54% | 58% | 70% | 67% |
| Ducted, 5 tons and up | 1 | 42% | 44% | 84% | 35% |
| Non-ducted, up to 1.5 tons | 14 | 50% | 30% | 35% | 39% |
| Non-ducted, 2 tons | 5 | 55% | 28% | 42% | 51% |
| Non-ducted, 2.5 to 3 tons | 8 | 35% | 44% | 23% | 29% |
| Non-ducted, 3.5 to 4.5 tons | 1 | 44% | 41% | 14% | 46% |
Every Innovair model in the market
- Innovair models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 179 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 354 | 1.85 | 1.89 | 2.00 | 2.40 | 2.63 |
| Ducted, 1.5 tons | 802 | 1.75 | 1.85 | 2.00 | 2.20 | 2.52 |
| Ducted, 2 tons | 791 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 758 | 1.70 | 1.80 | 1.90 | 2.10 | 2.44 |
| Ducted, 3 tons | 674 | 1.68 | 1.73 | 1.90 | 2.06 | 2.34 |
| Ducted, 3.5 tons | 662 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 373 | 1.70 | 1.80 | 1.91 | 2.02 | 2.50 |
| Ducted, 4.5 tons | 575 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 29 | 1.80 | 1.80 | 1.86 | 1.90 | 2.10 |
| Non-ducted, 0.5 tons | 774 | 1.75 | 1.80 | 1.94 | 2.09 | 2.19 |
| Non-ducted, 1 ton | 1,135 | 1.75 | 1.80 | 1.89 | 2.07 | 2.24 |
| Non-ducted, 1.5 tons | 946 | 1.75 | 1.80 | 1.87 | 2.07 | 2.20 |
| Non-ducted, 2 tons | 598 | 1.78 | 1.80 | 1.83 | 2.00 | 2.21 |
| Non-ducted, 2.5 tons | 327 | 1.75 | 1.80 | 1.84 | 1.86 | 2.02 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.80 | 1.90 | 2.00 | 2.07 |
| Non-ducted, 3.5 tons | 71 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 269 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 106 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 31 | 1.89 | 2.00 | 2.07 | 2.30 | 2.40 |
Source: AHRI Directory · as of
Innovair in the cold
- All listed models (median, middle 50% and 80%)
- Innovair (median, middle 50%)
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 3,710 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 3,710 | 65% | 68% | 76% | 83% | 92% |
| All rated models, 5°F | 3,710 | 55% | 58% | 66% | 75% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 3,710 | 2.64 | 2.87 | 3.1 | 3.32 | 3.53 |
| All rated models, 17°F | 3,710 | 1.98 | 2.05 | 2.2 | 2.34 | 2.49 |
| All rated models, 5°F | 3,710 | 1.8 | 1.83 | 1.92 | 2.03 | 2.21 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Innovair, 47°F | 29 | 100% | 100% | 100% | 100% | 100% |
| Innovair, 17°F | 29 | 64% | 70% | 82% | 88% | 95% |
| Innovair, 5°F | 29 | 57% | 63% | 75% | 81% | 84% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Innovair, 47°F | 29 | 2.31 | 2.53 | 3.04 | 3.32 | 3.5 |
| Innovair, 17°F | 29 | 1.88 | 2 | 2.2 | 2.32 | 2.42 |
| Innovair, 5°F | 29 | 1.8 | 1.84 | 1.9 | 2 | 2.11 |
Source: NEEP ccASHP list · as of
Top Innovair models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1SHV18H2R20INNOVAIR · SHV Serieswith ducted air handler WEV18H2R19 | 1.5 tons18,000 Btu/h · Ducted | 99% | 2.30 | 10.8 | 18,800 | 19.3 | CEE 25CEE 26XcelES CC | 4 | 213255597 | Ducted, up to 1.5 tons | 87.0 |
| 2EIN10H2V32(O)INNOVAIR · Innovair Elitewith ductless indoor unit EIN10H2V32(I) | 1 ton9,000 Btu/h · Non-ducted | 144% | 1.91 | 11.0 | 13,000 | 27.0 | CEE 25CEE 26XcelES CC | 1 | 206330207 | Non-ducted, up to 1.5 tons | 80.8 |
| 3SHV36H2R20INNOVAIR · SHV serieswith ducted air handler MAC36H2124E | 3 tons35,000 Btu/h · Ducted | 82% | 2.00 | 10.0 | 32,000 | 15.2 | CEE 25CEE 26XcelES CC | 5 | 213160476 | Ducted, 2.5 to 3 tons | 78.7 |
| 4MHD-24INNOVAIR · MHD serieswith ducted air handler MHD-CC2.0-17.5-M | 2 tons23,000 Btu/h · Ducted | 93% | 2.08 | 9.8 | 23,000 | 15.2 | XcelES CC | 2 | 210365430 | Ducted, 2 tons | 75.7 |
| 5SEV24H2R19INNOVAIR · SH serieswith ducted air handler WEV24H2R19 | 2 tons24,000 Btu/h · Ducted | 75% | 2.33 | 10.2 | 19,400 | 17.0 | CEE 25CEE 26XcelES CC | 5 | 213386881 | Ducted, 2 tons | 74.5 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1EIN10H2V32(O)INNOVAIR · Innovair Elitewith ductless indoor unit EIN10H2V32(I) | 1 ton9,000 Btu/h · Non-ducted | 144% | 1.91 | 11.0 | 27.0 | 16.6 | CEE 25CEE 26XcelES CC | 1 | 206330207 | Non-ducted, up to 1.5 tons | 89.1 | 80.8 | 97.4 | 80.8 |
| 2SHV18H2R20INNOVAIR · SHV Serieswith ducted air handler WEV18H2R19 | 1.5 tons18,000 Btu/h · Ducted | 99% | 2.30 | 10.8 | 19.3 | 12.1 | CEE 25CEE 26XcelES CC | 4 | 213255597 | Ducted, up to 1.5 tons | 82.9 | 87.0 | 78.9 | 87.0 |
| 3WIN09H7H51(O)Innovair · Quantum Hyper Heatwith ductless indoor unit WIN09H7H51(I) | 1 ton9,000 Btu/h · Non-ducted | 96% | 1.94 | 10.5 | 25.5 | 14.5 | CEE 25CEE 26XcelES CC | 1 | 208286573 | Non-ducted, up to 1.5 tons | 82.0 | 73.9 | 90.1 | 73.9 |
| 4VOM36H7R4P7Innovair · Multi Hyper | 2.5 tons32,000 Btu/h · Ducted | 113% | 1.84 | 8.9 | 19.5 | 12.0 | CEE 25CEE 26XcelES CC | 3 | 207821953 | Ducted, 2.5 to 3 tons | 78.7 | 69.3 | 88.0 | 69.3 |
| 5EIN24H2V32(O)INNOVAIR · Innovair Elitewith ductless indoor unit EIN24H2V32(I) | 2 tons22,000 Btu/h · Non-ducted | 100% | 1.90 | 9.5 | 21.5 | 13.0 | CEE 25CEE 26XcelES CC | 1 | 206330210 | Non-ducted, 2 tons | 77.1 | 69.9 | 84.3 | 69.9 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | VEA36H2V18 | 2.37 | Ducted, 2.5 to 3 tons | 91% | 206362548 |
| Capacity retention at 5°F | EIN10H2V32(O) | 144% | Non-ducted, up to 1.5 tons | 99% | 206330207 |
| HSPF2 | SHV18H2R20 | 10.8 | Ducted, up to 1.5 tons | 93% | 213255597 |
| SEER2 | VOM24H7R3P7 | 21.0 | Ducted, 2 tons | 96% | 207821950 |
| EER2 | EIN10H2V32(O) | 16.6 | Non-ducted, up to 1.5 tons | 99% | 206330207 |
| Heating capacity at 5°F | EIN18H2V32(O) | 20,000 Btu/h | Non-ducted, up to 1.5 tons | 96% | 206330209 |
Innovair size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 87.0(50 is the typical model of its size class)SHV18H2R20with ducted air handler WEV18H2R194 of 5 models qualify · AHRI 213255597 | 82.9(50 is the typical model of its size class)SHV18H2R20with ducted air handler WEV18H2R195 of 5 models have all five ratings · AHRI 213255597 |
| Ducted, 2 tons | 75.7(50 is the typical model of its size class)MHD-24with ducted air handler MHD-CC2.0-17.5-M4 of 5 models qualify · AHRI 210365430 | 71.7(50 is the typical model of its size class)VOM24H7R3P75 of 5 models have all five ratings · AHRI 207821950 |
| Ducted, 2.5 to 3 tons | 78.7(50 is the typical model of its size class)SHV36H2R20with ducted air handler MAC36H2124E4 of 7 models qualify · AHRI 213160476 | 78.7(50 is the typical model of its size class)VOM36H7R4P77 of 7 models have all five ratings · AHRI 207821953 |
| Ducted, 3.5 to 4.5 tons | 74.0(50 is the typical model of its size class)SHV48H2R20with ducted air handler DEV48H2R193 of 6 models qualify · AHRI 210343157 | 60.8(50 is the typical model of its size class)VOM42H7R5P76 of 6 models have all five ratings · AHRI 207821956 |
| Ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 41.9(50 is the typical model of its size class)SEV60H2R19with ducted air handler DEV60H2R191 of 1 models have all five ratings · AHRI 208106863 |
| Non-ducted, up to 1.5 tons | 80.8(50 is the typical model of its size class)EIN10H2V32(O)with ductless indoor unit EIN10H2V32(I)7 of 14 models qualify · AHRI 206330207 | 89.1(50 is the typical model of its size class)EIN10H2V32(O)with ductless indoor unit EIN10H2V32(I)11 of 14 models have all five ratings · AHRI 206330207 |
| Non-ducted, 2 tons | 69.9(50 is the typical model of its size class)EIN24H2V32(O)with ductless indoor unit EIN24H2V32(I)3 of 5 models qualify · AHRI 206330210 | 77.1(50 is the typical model of its size class)EIN24H2V32(O)with ductless indoor unit EIN24H2V32(I)4 of 5 models have all five ratings · AHRI 206330210 |
| Non-ducted, 2.5 to 3 tons | 65.0(50 is the typical model of its size class)VOM36H7R4P71 of 8 models qualify · AHRI 207821954 | 70.2(50 is the typical model of its size class)VOM36H7R4P77 of 8 models have all five ratings · AHRI 207821954 |
| Non-ducted, 3.5 to 4.5 tons | 41.8(50 is the typical model of its size class)VOM42H7R5P71 of 1 models qualify · AHRI 207821958 | 44.4(50 is the typical model of its size class)VOM42H7R5P71 of 1 models have all five ratings · AHRI 207821957 |
Newest Innovair certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| POS24H2XE5Ainnovairwith ductless indoor unit PHW24H2XERA | 2 tons22,000 Btu/h · Non-ducted | — | — | 8.0 | 17.0 | None | 1 | 217258410 |
| POS18H2XE5Ainnovairwith ductless indoor unit PHW18H2XERA | 1.5 tons16,500 Btu/h · Non-ducted | — | — | 8.5 | 17.0 | None | 1 | 217258409 |
| POS12H2XE5Ainnovairwith ductless indoor unit PHW12H2XERA | 1 ton11,000 Btu/h · Non-ducted | — | — | 8.0 | 17.0 | None | 1 | 217258408 |
| POS12H1XE5Ainnovairwith ductless indoor unit PHW12H1XERA | 1 ton11,000 Btu/h · Non-ducted | — | — | 8.0 | 17.0 | None | 1 | 217258407 |
| SEV30H2R19INNOVAIRwith ducted air handler M36E239+TD | 2.5 tons27,200 Btu/h · Ducted | 1.70 | 62% | 8.6 | 14.3 | None | 5 | 215444925 |
Compare Innovair
Innovair includes these brand names as listed in AHRI: INNOVAIR. Standards are checked against published thresholds; program rules beyond ratings are not checked.