Both views use the same certified data. This device remembers your choice.
K&A heat pump efficiency: 7 outdoor models compared
K&A has 7 heat pump outdoor models certified with this refrigerant group, in 7 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes K&A makes. K&A has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 7
- AHRI certifications
- 7
- Efficiency index
- 23%
- Typical model vs same-size, same-type peers (7 models)
- Meet CEE 2025
- 71.4%
- 5 models
How K&A compares with comparable models
- K&A
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index7 models scored | 23% | Not ranked | — |
| COP at 5°F7 models scored | 23% | Not ranked | 1.80 |
| Capacity retention at 5°F7 models scored | 32% | Not ranked | 70% |
| HSPF27 models scored | 19% | Not ranked | 8.5 |
| SEER27 models scored | 27% | Not ranked | 19.0 |
| EER27 models scored | 16% | Not ranked | 10.0 |
| Heating capacity at 5°F7 models scored | 34% | Not ranked | 8,600 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 71.4% | 5 |
| CEE 2026 Tier 1 (Split ASHP) | 57.1% | 4 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 57.1% | 4 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- K&A (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Non-ducted, up to 1.5 tons | 5 | 22% | 22% | 17% | 23% |
| Non-ducted, 2 tons | 1 | 26% | 31% | 22% | 37% |
| Non-ducted, 2.5 to 3 tons | 1 | 25% | 19% | 27% | 37% |
Every K&A model in the market
- K&A models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 179 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 354 | 1.85 | 1.89 | 2.00 | 2.40 | 2.63 |
| Ducted, 1.5 tons | 802 | 1.75 | 1.85 | 2.00 | 2.20 | 2.52 |
| Ducted, 2 tons | 791 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 758 | 1.70 | 1.80 | 1.90 | 2.10 | 2.44 |
| Ducted, 3 tons | 674 | 1.68 | 1.73 | 1.90 | 2.06 | 2.34 |
| Ducted, 3.5 tons | 662 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 373 | 1.70 | 1.80 | 1.91 | 2.02 | 2.50 |
| Ducted, 4.5 tons | 575 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 29 | 1.80 | 1.80 | 1.86 | 1.90 | 2.10 |
| Non-ducted, 0.5 tons | 774 | 1.75 | 1.80 | 1.94 | 2.09 | 2.19 |
| Non-ducted, 1 ton | 1,135 | 1.75 | 1.80 | 1.89 | 2.07 | 2.24 |
| Non-ducted, 1.5 tons | 946 | 1.75 | 1.80 | 1.87 | 2.07 | 2.20 |
| Non-ducted, 2 tons | 598 | 1.78 | 1.80 | 1.83 | 2.00 | 2.21 |
| Non-ducted, 2.5 tons | 327 | 1.75 | 1.80 | 1.84 | 1.86 | 2.02 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.80 | 1.90 | 2.00 | 2.07 |
| Non-ducted, 3.5 tons | 71 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 269 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 106 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 31 | 1.89 | 2.00 | 2.07 | 2.30 | 2.40 |
Source: AHRI Directory · as of
Top K&A models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1MAJESTIC-12HVT110-USK&Awith ductless indoor unit MAJESTIC-12HVT110-USAlso listed as MAJESTIC-12HVT-US | 1 ton12,000 Btu/h · Non-ducted | 70% | 1.80 | 8.5 | 8,600 | 19.0 | CEE 25CEE 26Xcel | 1 | 212369703 | Non-ducted, up to 1.5 tons | 30.5 |
| 2MAJESTIC-09HVT-USK&Awith ductless indoor unit MAJESTIC-09HVT-US | 1 ton9,000 Btu/h · Non-ducted | 70% | 1.80 | 8.5 | 7,000 | 19.0 | CEE 25CEE 26Xcel | 1 | 212369704 | Non-ducted, up to 1.5 tons | 28.3 |
| 3MAJESTIC-09HVT110-USK&Awith ductless indoor unit MAJESTIC-09HVT110-US | 1 ton9,000 Btu/h · Non-ducted | 70% | 1.75 | 8.5 | 7,000 | 19.0 | CEE 25CEE 26Xcel | 1 | 212369702 | Non-ducted, up to 1.5 tons | 22.4 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1MAJESTIC-24HVT-USK&Awith ductless indoor unit MAJESTIC-24HVT-US | 2 tons24,000 Btu/h · Non-ducted | 61% | 1.80 | 8.5 | 19.0 | 10.0 | CEE 25 | 1 | 212369707 | Non-ducted, 2 tons | 26.1 | 21.7 | 30.5 | Not a pick |
| 2MAJESTIC-36HVT-USK&Awith ductless indoor unit MAJESTIC-36HVT-US | 3 tons36,000 Btu/h · Non-ducted | 58% | 1.80 | 8.5 | 19.0 | 9.0 | None | 1 | 212369708 | Non-ducted, 2.5 to 3 tons | 24.9 | 20.4 | 29.4 | Not a pick |
| 3MAJESTIC-12HVT110-USK&Awith ductless indoor unit MAJESTIC-12HVT110-USAlso listed as MAJESTIC-12HVT-US | 1 ton12,000 Btu/h · Non-ducted | 70% | 1.80 | 8.5 | 19.0 | 10.0 | CEE 25CEE 26Xcel | 1 | 212369703 | Non-ducted, up to 1.5 tons | 24.8 | 30.5 | 19.1 | 30.5 |
| 4MAJESTIC-09HVT-USK&Awith ductless indoor unit MAJESTIC-09HVT-US | 1 ton9,000 Btu/h · Non-ducted | 70% | 1.80 | 8.5 | 19.0 | 10.0 | CEE 25CEE 26Xcel | 1 | 212369704 | Non-ducted, up to 1.5 tons | 23.7 | 28.3 | 19.1 | 28.3 |
| 5MAJESTIC-09HVT110-USK&Awith ductless indoor unit MAJESTIC-09HVT110-US | 1 ton9,000 Btu/h · Non-ducted | 70% | 1.75 | 8.5 | 19.0 | 10.0 | CEE 25CEE 26Xcel | 1 | 212369702 | Non-ducted, up to 1.5 tons | 20.7 | 22.4 | 19.1 | 22.4 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | MAJESTIC-24HVT-US | 1.80 | Non-ducted, 2 tons | 31% | 212369707 |
| Capacity retention at 5°F | MAJESTIC-12HVT110-USAlso listed as MAJESTIC-12HVT-US | 70% | Non-ducted, up to 1.5 tons | 48% | 212369703 |
| HSPF2 | MAJESTIC-36HVT-US | 8.5 | Non-ducted, 2.5 to 3 tons | 26% | 212369708 |
| SEER2 | MAJESTIC-24HVT-US | 19.0 | Non-ducted, 2 tons | 36% | 212369707 |
| EER2 | MAJESTIC-24HVT-US | 10.0 | Non-ducted, 2 tons | 24% | 212369707 |
| Heating capacity at 5°F | MAJESTIC-18HVT-US | 11,600 Btu/h | Non-ducted, up to 1.5 tons | 62% | 212369706 |
K&A size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 30.5(50 is the typical model of its size class)MAJESTIC-12HVT110-USwith ductless indoor unit MAJESTIC-12HVT110-USAlso listed as MAJESTIC-12HVT-US4 of 5 models qualify · AHRI 212369703 | 24.8(50 is the typical model of its size class)MAJESTIC-12HVT110-USwith ductless indoor unit MAJESTIC-12HVT110-USAlso listed as MAJESTIC-12HVT-US5 of 5 models have all five ratings · AHRI 212369703 |
| Non-ducted, 2 tons | None on this board (0 of 1 models qualify) | 26.1(50 is the typical model of its size class)MAJESTIC-24HVT-USwith ductless indoor unit MAJESTIC-24HVT-US1 of 1 models have all five ratings · AHRI 212369707 |
| Non-ducted, 2.5 to 3 tons | None on this board (0 of 1 models qualify) | 24.9(50 is the typical model of its size class)MAJESTIC-36HVT-USwith ductless indoor unit MAJESTIC-36HVT-US1 of 1 models have all five ratings · AHRI 212369708 |
Newest K&A certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| MAJESTIC-36HVT-USK&Awith ductless indoor unit MAJESTIC-36HVT-US | 3 tons36,000 Btu/h · Non-ducted | 1.80 | 58% | 8.5 | 19.0 | None | 1 | 212369708 |
| MAJESTIC-24HVT-USK&Awith ductless indoor unit MAJESTIC-24HVT-US | 2 tons24,000 Btu/h · Non-ducted | 1.80 | 61% | 8.5 | 19.0 | CEE 25 | 1 | 212369707 |
| MAJESTIC-18HVT-USK&Awith ductless indoor unit MAJESTIC-18HVT-US | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 59% | 8.5 | 19.0 | None | 1 | 212369706 |
| MAJESTIC-12HVT-USK&Awith ductless indoor unit MAJESTIC-12HVT-US | 1 ton12,000 Btu/h · Non-ducted | 1.80 | 70% | 8.5 | 19.0 | CEE 25CEE 26Xcel | 1 | 212369705 |
| MAJESTIC-09HVT-USK&Awith ductless indoor unit MAJESTIC-09HVT-US | 1 ton9,000 Btu/h · Non-ducted | 1.80 | 70% | 8.5 | 19.0 | CEE 25CEE 26Xcel | 1 | 212369704 |
Compare K&A