Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
K&A heat pump efficiency: 23 outdoor models compared
K&A has 23 heat pump outdoor models certified with this refrigerant group, in 23 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes K&A makes. K&A has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 23
- AHRI certifications
- 23
- Efficiency index
- 30%
- Typical model vs same-size, same-type peers (16 models)
- Meet CEE 2025
- 17.4%
- 4 models
How K&A compares with comparable models
- K&A
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index16 models scored | 30% | Not ranked | — |
| COP at 5°F16 models scored | 31% | Not ranked | 1.80 |
| Capacity retention at 5°F16 models scored | 39% | Not ranked | 71% |
| HSPF223 models scored | 33% | Not ranked | 7.6 |
| SEER223 models scored | 27% | Not ranked | 14.6 |
| EER223 models scored | 28% | Not ranked | 9.9 |
| Heating capacity at 5°F16 models scored | 44% | Not ranked | 18,800 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 17.4% | 4 |
| CEE 2026 Tier 1 (Split ASHP) | 17.4% | 4 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 17.4% | 4 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- K&A (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 1 | — | — | 14% | 22% |
| Ducted, 2 tons | 4 | 37% | 29% | 24% | 34% |
| Ducted, 2.5–3 tons | 5 | 26% | 21% | 31% | 28% |
| Ducted, 3.5–4.5 tons | 9 | 39% | 45% | 44% | 33% |
| Non-ducted, up to 1.5 tons | 3 | 13% | 22% | 22% | 8% |
| Non-ducted, 2 tons | 1 | 13% | 17% | 44% | 4% |
Every K&A model in the market
- K&A models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 865 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 726 | 1.80 | 1.86 | 2.00 | 2.12 | 2.41 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top K&A models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1DIVINE-48K220V-7-OK&Awith ducted air handler DIVINE-48K220V-7-I | 4 tons47,000 Btu/h · Ducted | 72% | 2.30 | 9.2 | 34,000 | 18.5 | CEE 25CEE 26Xcel | 1 | 217656090 | Ducted, 3.5–4.5 tons | 72.2 |
| 2DIVINE-60K220V-7-OK&Awith ducted air handler DIVINE-60K220V-7-I | 4.5 tons55,000 Btu/h · Ducted | 73% | 2.30 | 8.8 | 40,000 | 17.0 | CEE 25CEE 26Xcel | 1 | 217656091 | Ducted, 3.5–4.5 tons | 69.8 |
| 3DIVINE-24K220V-7-OK&Awith ducted air handler DIVINE-24K220V-7-I | 2 tons24,000 Btu/h · Ducted | 79% | 2.15 | 8.8 | 19,000 | 18.5 | CEE 25CEE 26Xcel | 1 | 217656088 | Ducted, 2 tons | 60.4 |
| 4DIVINE-36K220V-7-OK&Awith ducted air handler DIVINE-36K220V-7-I | 3 tons33,000 Btu/h · Ducted | 73% | 2.00 | 8.8 | 24,000 | 18.0 | CEE 25CEE 26Xcel | 1 | 217656089 | Ducted, 2.5–3 tons | 59.2 |
| 5CELESTIAL-48K220V-7K&AAlso listed as CELESTIAL-48K220V-7 | 4 tons48,000 Btu/h · Ducted | 72% | 1.82 | 7.8 | 34,600 | 14.6 | None | 1 | 218157773 | Ducted, 3.5–4.5 tons | 41.0 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1DIVINE-48K220V-7-OK&Awith ducted air handler DIVINE-48K220V-7-I | 4 tons47,000 Btu/h · Ducted | 72% | 2.30 | 9.2 | 18.5 | 11.5 | CEE 25CEE 26Xcel | 1 | 217656090 | Ducted, 3.5–4.5 tons | 72.6 | 72.2 | 73.0 | 72.2 |
| 2DIVINE-24K220V-7-OK&Awith ducted air handler DIVINE-24K220V-7-I | 2 tons24,000 Btu/h · Ducted | 79% | 2.15 | 8.8 | 18.5 | 12.5 | CEE 25CEE 26Xcel | 1 | 217656088 | Ducted, 2 tons | 68.1 | 60.4 | 75.7 | 60.4 |
| 3DIVINE-36K220V-7-OK&Awith ducted air handler DIVINE-36K220V-7-I | 3 tons33,000 Btu/h · Ducted | 73% | 2.00 | 8.8 | 18.0 | 11.2 | CEE 25CEE 26Xcel | 1 | 217656089 | Ducted, 2.5–3 tons | 57.5 | 59.2 | 55.7 | 59.2 |
| 4DIVINE-60K220V-7-OK&Awith ducted air handler DIVINE-60K220V-7-I | 4.5 tons55,000 Btu/h · Ducted | 73% | 2.30 | 8.8 | 17.0 | 10.0 | CEE 25CEE 26Xcel | 1 | 217656091 | Ducted, 3.5–4.5 tons | 56.6 | 69.8 | 43.5 | 69.8 |
| 5CELESTIAL-48K220V-7K&AAlso listed as CELESTIAL-48K220V-7 | 4 tons48,000 Btu/h · Ducted | 72% | 1.82 | 7.8 | 14.6 | 9.3 | None | 1 | 218157773 | Ducted, 3.5–4.5 tons | 31.9 | 41.0 | 22.7 | 41.0 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | DIVINE-48K220V-7-O | 2.30 | Ducted, 3.5–4.5 tons | 86% | 217656090 |
| Capacity retention at 5°F | DIVINE-24K220V-7-O | 79% | Ducted, 2 tons | 57% | 217656088 |
| HSPF2 | DIVINE-48K220V-7-O | 9.2 | Ducted, 3.5–4.5 tons | 74% | 217656090 |
| SEER2 | DIVINE-48K220V-7-O | 18.5 | Ducted, 3.5–4.5 tons | 81% | 217656090 |
| EER2 | DIVINE-24K220V-7-O | 12.5 | Ducted, 2 tons | 81% | 217656088 |
| Heating capacity at 5°F | DIVINE-60K220V-7-O | 40,000 Btu/h | Ducted, 3.5–4.5 tons | 68% | 217656091 |
K&A size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 1 models qualify) | None on this board (0 of 1 models have all five ratings) |
| Ducted, 2 tons | 60.4(50 is the typical model of its size class)DIVINE-24K220V-7-Owith ducted air handler DIVINE-24K220V-7-I3 of 4 models qualify · AHRI 217656088 | 68.1(50 is the typical model of its size class)DIVINE-24K220V-7-Owith ducted air handler DIVINE-24K220V-7-I3 of 4 models have all five ratings · AHRI 217656088 |
| Ducted, 2.5–3 tons | 59.2(50 is the typical model of its size class)DIVINE-36K220V-7-Owith ducted air handler DIVINE-36K220V-7-I1 of 5 models qualify · AHRI 217656089 | 57.5(50 is the typical model of its size class)DIVINE-36K220V-7-Owith ducted air handler DIVINE-36K220V-7-I3 of 5 models have all five ratings · AHRI 217656089 |
| Ducted, 3.5–4.5 tons | 72.2(50 is the typical model of its size class)DIVINE-48K220V-7-Owith ducted air handler DIVINE-48K220V-7-I4 of 9 models qualify · AHRI 217656090 | 72.6(50 is the typical model of its size class)DIVINE-48K220V-7-Owith ducted air handler DIVINE-48K220V-7-I6 of 9 models have all five ratings · AHRI 217656090 |
| Non-ducted, up to 1.5 tons | None on this board (0 of 3 models qualify) | 22.1(50 is the typical model of its size class)MAJESTIC-12K110V-S2with ductless indoor unit MAJESTIC-12K110V-S23 of 3 models have all five ratings · AHRI 216723132 |
| Non-ducted, 2 tons | None on this board (0 of 1 models qualify) | 13.4(50 is the typical model of its size class)MAJESTIC-24K220V-S2with ductless indoor unit MAJESTIC-24K220V-S21 of 1 models have all five ratings · AHRI 216723135 |
Newest K&A certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| CELESTIAL-60K220V-7*K&A | 4.5 tons55,000 Btu/h · Ducted | 1.80 | 68% | 7.6 | 13.4 | None | 1 | 218814648 |
| CELESTIAL-48K220V-7*K&A | 4 tons48,000 Btu/h · Ducted | 1.82 | 72% | 7.8 | 14.6 | None | 1 | 218814647 |
| CELESTIAL-36K220V-7*K&A | 3 tons34,600 Btu/h · Ducted | 1.58 | 52% | 7.1 | 13.8 | None | 1 | 218814646 |
| CELESTIAL-24K220V-7*K&A | 2 tons24,000 Btu/h · Ducted | 1.64 | 77% | 7.2 | 15.2 | None | 1 | 218814645 |
| DIVINE-60K220VHP-S2-OK&Awith ducted air handler DIVINE-60K220VCO-S2-I | 4.5 tons55,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | None | 1 | 218426311 |
Compare K&A
K&A includes these brand names as listed in AHRI: K&A. Standards are checked against published thresholds; program rules beyond ratings are not checked.