Skip to content

K&A vs Manuflow heat pumps

Measured against models of the same size and duct type, Manuflow scores higher on 6 of the 6 ratings. K&A has 23 outdoor models, Manuflow has 23 outdoor models. K&A and Manuflow have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
K&A and Manuflow on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Manuflow scores higher on 6 of the 6 ratings.
  • K&A
  • Manuflow
  • Other ranked manufacturers
K&AManuflow

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingK&AManuflow
Efficiency index30%median —47%median —
COP at 5°F31%median 1.8037%median 1.80
Capacity retention at 5°F39%median 71%42%median 73%
HSPF233%median 7.656%median 10.0
SEER227%median 14.658%median 22.0
EER228%median 9.938%median 11.2
Heating capacity at 5°F44%median 18,800 Btu/h51%median 13,200 Btu/h
Outdoor models2323
AHRI certifications2323

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardK&AManuflow
CEE 2025 Tier 1 (Split ASHP)17.4%4 models82.6%19 models
CEE 2026 Tier 1 (Split ASHP)17.4%4 models82.6%19 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)17.4%4 models78.3%18 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 4 groups where both have models
  • K&A
  • Manuflow
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeK&AManuflow
Ducted, up to 1.5 tons1 · index —2 · index 50%
Ducted, 2 tons4 · index 37%1 · index 56%
Ducted, 2.5–3 tons5 · index 26%None
Ducted, 3.5–4.5 tons9 · index 39%None
Non-ducted, up to 1.5 tons3 · index 13%12 · index 47%
Non-ducted, 2 tons1 · index 13%4 · index 44%
Non-ducted, 2.5–3 tonsNone3 · index 46%
Non-ducted, 3.5–4.5 tonsNone1 · index 42%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeK&ACold-climate score, best modelManuflowCold-climate score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 1 models qualify)54.1(50 is the typical model of its size class)TSDUC18HR2VIR45I*2 of 2 models qualify · AHRI 216763014
Ducted, 2 tons60.4(50 is the typical model of its size class) (higher)DIVINE-24K220V-7-Owith ducted air handler DIVINE-24K220V-7-I3 of 4 models qualify · AHRI 21765608860.1(50 is the typical model of its size class)TSDUC24CD2VIR45I*1 of 1 models qualify · AHRI 216763015
Ducted, 2.5–3 tons59.2(50 is the typical model of its size class)DIVINE-36K220V-7-Owith ducted air handler DIVINE-36K220V-7-I1 of 5 models qualify · AHRI 217656089No models in this size class
Ducted, 3.5–4.5 tons72.2(50 is the typical model of its size class)DIVINE-48K220V-7-Owith ducted air handler DIVINE-48K220V-7-I4 of 9 models qualify · AHRI 217656090No models in this size class
Non-ducted, up to 1.5 tonsNone on this board (0 of 3 models qualify)68.6(50 is the typical model of its size class)TFM2G18CHAIR454B9 of 12 models qualify · AHRI 216763003
Non-ducted, 2 tonsNone on this board (0 of 1 models qualify)58.8(50 is the typical model of its size class)TSCAS24CD2VIR45I*with ductless indoor unit TSCAS24CD2VIR45I3 of 4 models qualify · AHRI 216763012
Non-ducted, 2.5–3 tonsNo models in this size class57.5(50 is the typical model of its size class)TFM3G27CHAIR454B2 of 3 models qualify · AHRI 216763004
Non-ducted, 3.5–4.5 tonsNo models in this size class31.2(50 is the typical model of its size class)TFM5G42CHAIR454B1 of 1 models qualify · AHRI 216763006

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeK&AAll-around score, best modelManuflowAll-around score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 1 models have all five ratings)57.0(50 is the typical model of its size class)TSDUC18HR2VIR45I*2 of 2 models have all five ratings · AHRI 216763014
Ducted, 2 tons68.1(50 is the typical model of its size class) (higher)DIVINE-24K220V-7-Owith ducted air handler DIVINE-24K220V-7-I3 of 4 models have all five ratings · AHRI 21765608855.8(50 is the typical model of its size class)TSDUC24CD2VIR45I*1 of 1 models have all five ratings · AHRI 216763015
Ducted, 2.5–3 tons57.5(50 is the typical model of its size class)DIVINE-36K220V-7-Owith ducted air handler DIVINE-36K220V-7-I3 of 5 models have all five ratings · AHRI 217656089No models in this size class
Ducted, 3.5–4.5 tons72.6(50 is the typical model of its size class)DIVINE-48K220V-7-Owith ducted air handler DIVINE-48K220V-7-I6 of 9 models have all five ratings · AHRI 217656090No models in this size class
Non-ducted, up to 1.5 tons22.1(50 is the typical model of its size class)MAJESTIC-12K110V-S2with ductless indoor unit MAJESTIC-12K110V-S23 of 3 models have all five ratings · AHRI 21672313274.4(50 is the typical model of its size class) (higher)THH12E2S25NAR454Owith ductless indoor unit THH12E2S25NAR454I12 of 12 models have all five ratings · AHRI 216707861
Non-ducted, 2 tons13.4(50 is the typical model of its size class)MAJESTIC-24K220V-S2with ductless indoor unit MAJESTIC-24K220V-S21 of 1 models have all five ratings · AHRI 21672313556.5(50 is the typical model of its size class) (higher)TSCAS24CD2VIR45I*with ductless indoor unit TSCAS24CD2VIR45I4 of 4 models have all five ratings · AHRI 216763012
Non-ducted, 2.5–3 tonsNo models in this size class65.1(50 is the typical model of its size class)TFM3G27CHAIR454B3 of 3 models have all five ratings · AHRI 216763004
Non-ducted, 3.5–4.5 tonsNo models in this size class42.4(50 is the typical model of its size class)TFM5G42CHAIR454B1 of 1 models have all five ratings · AHRI 216763006

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingK&AManuflow
COP at 5°Fbeats 86% · 2.30DIVINE-48K220V-7-ODucted, 3.5–4.5 tonsbeats 81% · 2.03TSHG36E2S19NAR45ONon-ducted, 2.5–3 tons
Capacity retention at 5°Fbeats 57% · 79%DIVINE-24K220V-7-ODucted, 2 tonsbeats 87% · 100%THH12E2S25NAR454ONon-ducted, up to 1.5 tons
HSPF2beats 74% · 9.2DIVINE-48K220V-7-ODucted, 3.5–4.5 tonsbeats 81% · 10.4TSCAS24CD2VIR45I*Non-ducted, 2 tons
SEER2beats 81% · 18.5DIVINE-48K220V-7-ODucted, 3.5–4.5 tonsbeats 91% · 24.0TFM3G27CHAIR454BNon-ducted, 2.5–3 tons
EER2beats 81% · 12.5DIVINE-24K220V-7-ODucted, 2 tonsbeats 83% · 14.0THH12E2S25NAR454ONon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 68% · 40,000 Btu/hDIVINE-60K220V-7-ODucted, 3.5–4.5 tonsbeats 90% · 17,800 Btu/hTHH18E2S24NAR454ONon-ducted, up to 1.5 tons

More comparisons