APPLIED COMFORT vs K&A heat pumps
Measured against models of the same size and duct type, K&A scores higher on 6 of the 6 ratings. APPLIED COMFORT has 23 outdoor models, K&A has 23 outdoor models. APPLIED COMFORT and K&A have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- APPLIED COMFORT
- K&A
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | APPLIED COMFORT | K&A |
|---|---|---|
| Efficiency index | 20%median — | 31%median — |
| COP at 5°F | 30%median 1.80 | 32%median 1.80 |
| Capacity retention at 5°F | 17%median 62% | 39%median 71% |
| HSPF2 | 7%median 7.1 | 34%median 7.6 |
| SEER2 | 24%median 14.4 | 28%median 14.6 |
| EER2 | 21%median 9.9 | 30%median 9.9 |
| Heating capacity at 5°F | 36%median 6,900 Btu/h | 44%median 18,800 Btu/h |
| Outdoor models | 23 | 23 |
| AHRI certifications | 23 | 23 |
Share of models meeting each standard
| Standard | APPLIED COMFORT | K&A |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0%0 models | 17.4%4 models |
| CEE 2026 Tier 1 (Split ASHP) | 0%0 models | 17.4%4 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0%0 models | 17.4%4 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- APPLIED COMFORT
- K&A
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | APPLIED COMFORT | K&A |
|---|---|---|
| Ducted, up to 1.5 tons | 23 · index 20% | 1 · index — |
| Ducted, 2 tons | None | 4 · index 40% |
| Ducted, 2.5 to 3 tons | None | 5 · index 26% |
| Ducted, 3.5 to 4.5 tons | None | 9 · index 40% |
| Non-ducted, up to 1.5 tons | None | 3 · index 14% |
| Non-ducted, 2 tons | None | 1 · index 15% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | APPLIED COMFORTCold-climate score, best model | K&ACold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 42.6(50 is the typical model of its size class)TPHE10K10E6A30Also listed as TPHE10K10E6A31, TPHE10K20E7A315 of 23 models qualify · AHRI 218745183 | None on this board (0 of 1 models qualify) |
| Ducted, 2 tons | No models in this size class | 67.6(50 is the typical model of its size class)DIVINE-24K220V-7-Owith ducted air handler DIVINE-24K220V-7-I3 of 4 models qualify · AHRI 217656088 |
| Ducted, 2.5 to 3 tons | No models in this size class | 59.2(50 is the typical model of its size class)DIVINE-36K220V-7-Owith ducted air handler DIVINE-36K220V-7-I1 of 5 models qualify · AHRI 217656089 |
| Ducted, 3.5 to 4.5 tons | No models in this size class | 72.3(50 is the typical model of its size class)DIVINE-48K220V-7-Owith ducted air handler DIVINE-48K220V-7-I4 of 9 models qualify · AHRI 217656090 |
| Non-ducted, up to 1.5 tons | No models in this size class | None on this board (0 of 3 models qualify) |
| Non-ducted, 2 tons | No models in this size class | None on this board (0 of 1 models qualify) |
All-around best
| Size and duct type | APPLIED COMFORTAll-around score, best model | K&AAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 37.5(50 is the typical model of its size class)TPHE10K10E6A30Also listed as TPHE10K10E6A31, TPHE10K20E7A3123 of 23 models have all five ratings · AHRI 218745183 | None on this board (0 of 1 models have all five ratings) |
| Ducted, 2 tons | No models in this size class | 76.5(50 is the typical model of its size class)DIVINE-24K220V-7-Owith ducted air handler DIVINE-24K220V-7-I3 of 4 models have all five ratings · AHRI 217656088 |
| Ducted, 2.5 to 3 tons | No models in this size class | 58.3(50 is the typical model of its size class)DIVINE-36K220V-7-Owith ducted air handler DIVINE-36K220V-7-I3 of 5 models have all five ratings · AHRI 217656089 |
| Ducted, 3.5 to 4.5 tons | No models in this size class | 73.3(50 is the typical model of its size class)DIVINE-48K220V-7-Owith ducted air handler DIVINE-48K220V-7-I6 of 9 models have all five ratings · AHRI 217656090 |
| Non-ducted, up to 1.5 tons | No models in this size class | 23.4(50 is the typical model of its size class)MAJESTIC-12K110V-S2with ductless indoor unit MAJESTIC-12K110V-S23 of 3 models have all five ratings · AHRI 216723132 |
| Non-ducted, 2 tons | No models in this size class | 14.6(50 is the typical model of its size class)MAJESTIC-24K220V-S2with ductless indoor unit MAJESTIC-24K220V-S21 of 1 models have all five ratings · AHRI 216723135 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | APPLIED COMFORT | K&A |
|---|---|---|
| COP at 5°F | beats 89% · 2.32TPHE10K10E6A30Also listed as TPHE10K10E6A31, TPHE10K20E7A31Ducted, up to 1.5 tons | beats 86% · 2.30DIVINE-48K220V-7-ODucted, 3.5 to 4.5 tons |
| Capacity retention at 5°F | beats 42% · 72%TPHE10L00E6A30Also listed as TPHE10L00E6A31Ducted, up to 1.5 tons | beats 56% · 79%DIVINE-24K220V-7-ODucted, 2 tons |
| HSPF2 | beats 14% · 7.5TPHE10K10E6A30Also listed as TPHE10K10E6A31, TPHE10K20E7A31Ducted, up to 1.5 tons | beats 74% · 9.2DIVINE-48K220V-7-ODucted, 3.5 to 4.5 tons |
| SEER2 | beats 52% · 16.4TPHE10K10E6A30Also listed as TPHE10K10E6A31, TPHE10K20E7A31Ducted, up to 1.5 tons | beats 81% · 18.5DIVINE-48K220V-7-ODucted, 3.5 to 4.5 tons |
| EER2 | beats 34% · 11.1V120HE09K34E7MA30Also listed as V120HE12K50E8MA30, V120HE12K34E7MA30, V120HE15K50E8MA30, V120HE15K34E7MA30 and 5 moreDucted, up to 1.5 tons | beats 91% · 13.2DIVINE-24K220V-7-ODucted, 2 tons |
| Heating capacity at 5°F | beats 58% · 11,100 Btu/hV120HE16K50E8MA30Also listed as V120HE18K72E0MA30, V120HE18K50E8MA30, V120HE24K72E0MA30, VI20HE16K50E8MA30 and 3 moreDucted, up to 1.5 tons | beats 68% · 40,000 Btu/hDIVINE-60K220V-7-ODucted, 3.5 to 4.5 tons |