APPLIED COMFORT heat pump efficiency: 23 outdoor models compared
APPLIED COMFORT has 23 heat pump outdoor models certified with this refrigerant group, in 23 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes APPLIED COMFORT makes. APPLIED COMFORT has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 23
- AHRI certifications
- 23
- Efficiency index
- 21%
- Typical model vs same-size, same-type peers (23 models)
- Meet CEE 2025
- 0%
- 0 models
How APPLIED COMFORT compares with comparable models
- APPLIED COMFORT
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index23 models scored | 21% | Not ranked | — |
| COP at 5°F23 models scored | 30% | Not ranked | 1.80 |
| Capacity retention at 5°F23 models scored | 18% | Not ranked | 62% |
| HSPF223 models scored | 7% | Not ranked | 7.1 |
| SEER223 models scored | 24% | Not ranked | 14.4 |
| EER223 models scored | 21% | Not ranked | 9.9 |
| Heating capacity at 5°F23 models scored | 37% | Not ranked | 6,900 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0% | 0 |
| CEE 2026 Tier 1 (Split ASHP) | 0% | 0 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0% | 0 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- APPLIED COMFORT (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 23 | 21% | 30% | 7% | 24% |
Every APPLIED COMFORT model in the market
- APPLIED COMFORT models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top APPLIED COMFORT models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1TPHE10K10E6A30Applied ComfortAlso listed as TPHE10K10E6A31, TPHE10K20E7A31 | 1 ton10,000 Btu/h · Ducted | 70% | 2.32 | 7.5 | 6,300 | 16.4 | None | 1 | 218745183 | Ducted, up to 1.5 tons | 43.0 |
| 2TPHE10L00E6A30Applied ComfortAlso listed as TPHE10L00E6A31 | 1 ton10,000 Btu/h · Ducted | 72% | 1.80 | 7.5 | 6,500 | 15.0 | None | 1 | 218745186 | Ducted, up to 1.5 tons | 31.8 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1TPHE10K10E6A30Applied ComfortAlso listed as TPHE10K10E6A31, TPHE10K20E7A31 | 1 ton10,000 Btu/h · Ducted | 70% | 2.32 | 7.5 | 16.4 | 9.9 | None | 1 | 218745183 | Ducted, up to 1.5 tons | 37.9 | 43.0 | 32.8 | 43.0 |
| 2TPHE10L00E6A30Applied ComfortAlso listed as TPHE10L00E6A31 | 1 ton10,000 Btu/h · Ducted | 72% | 1.80 | 7.5 | 15.0 | 9.5 | None | 1 | 218745186 | Ducted, up to 1.5 tons | 26.1 | 31.8 | 20.5 | 31.8 |
| 3V120HE09K34E7MA30APPLIED COMFORTAlso listed as V120HE12K50E8MA30, V120HE12K34E7MA30, V120HE15K50E8MA30, V120HE15K34E7MA30 and 5 more | 1 ton12,600 Btu/h · Ducted | 56% | 1.61 | 6.5 | 14.4 | 11.1 | None | 1 | 217607342 | Ducted, up to 1.5 tons | 19.4 | 5.4 | 33.3 | Not a pick |
| 4V120HE16K50E8MA30APPLIED COMFORTAlso listed as V120HE18K72E0MA30, V120HE18K50E8MA30, V120HE24K72E0MA30, VI20HE16K50E8MA30 and 3 more | 1.5 tons18,300 Btu/h · Ducted | 62% | 1.82 | 7.1 | 12.8 | 9.7 | None | 1 | 217607347 | Ducted, up to 1.5 tons | 13.8 | 22.0 | 5.6 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | TPHE10K10E6A30Also listed as TPHE10K10E6A31, TPHE10K20E7A31 | 2.32 | Ducted, up to 1.5 tons | 89% | 218745183 |
| Capacity retention at 5°F | TPHE10L00E6A30Also listed as TPHE10L00E6A31 | 72% | Ducted, up to 1.5 tons | 42% | 218745186 |
| HSPF2 | TPHE10K10E6A30Also listed as TPHE10K10E6A31, TPHE10K20E7A31 | 7.5 | Ducted, up to 1.5 tons | 14% | 218745183 |
| SEER2 | TPHE10K10E6A30Also listed as TPHE10K10E6A31, TPHE10K20E7A31 | 16.4 | Ducted, up to 1.5 tons | 52% | 218745183 |
| EER2 | V120HE09K34E7MA30Also listed as V120HE12K50E8MA30, V120HE12K34E7MA30, V120HE15K50E8MA30, V120HE15K34E7MA30 and 5 more | 11.1 | Ducted, up to 1.5 tons | 34% | 217607342 |
| Heating capacity at 5°F | V120HE16K50E8MA30Also listed as V120HE18K72E0MA30, V120HE18K50E8MA30, V120HE24K72E0MA30, VI20HE16K50E8MA30 and 3 more | 11,100 Btu/h | Ducted, up to 1.5 tons | 59% | 217607347 |
APPLIED COMFORT size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 43.0(50 is the typical model of its size class)TPHE10K10E6A30Also listed as TPHE10K10E6A31, TPHE10K20E7A315 of 23 models qualify · AHRI 218745183 | 37.9(50 is the typical model of its size class)TPHE10K10E6A30Also listed as TPHE10K10E6A31, TPHE10K20E7A3123 of 23 models have all five ratings · AHRI 218745183 |
Newest APPLIED COMFORT certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| TPHE10L00E6A31Applied Comfort | 1 ton10,000 Btu/h · Ducted | 1.80 | 72% | 7.5 | 15.0 | None | 1 | 218745187 |
| TPHE10L00E6A30Applied Comfort | 1 ton10,000 Btu/h · Ducted | 1.80 | 72% | 7.5 | 15.0 | None | 1 | 218745186 |
| TPHE10K20E7A31Applied Comfort | 1 ton10,000 Btu/h · Ducted | 2.32 | 70% | 7.5 | 16.4 | None | 1 | 218745185 |
| TPHE10K10E6A31Applied Comfort | 1 ton10,000 Btu/h · Ducted | 2.32 | 70% | 7.5 | 16.4 | None | 1 | 218745184 |
| TPHE10K10E6A30Applied Comfort | 1 ton10,000 Btu/h · Ducted | 2.32 | 70% | 7.5 | 16.4 | None | 1 | 218745183 |