Skip to content

IWAE vs K&A heat pumps

Measured against models of the same size and duct type, IWAE scores higher on 5 of the 6 ratings. IWAE has 23 outdoor models, K&A has 23 outdoor models. IWAE and K&A have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
IWAE and K&A on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, IWAE scores higher on 5 of the 6 ratings.
  • IWAE
  • K&A
  • Other ranked manufacturers
IWAEK&A

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingIWAEK&A
Efficiency index52% (higher)median —30% (higher)median —
COP at 5°F26%median 1.8031%median 1.80
Capacity retention at 5°F61% (higher)median 80%39% (higher)median 71%
HSPF235% (higher)median 8.033% (higher)median 7.6
SEER240% (higher)median 17.027% (higher)median 14.6
EER236% (higher)median 11.228% (higher)median 9.9
Heating capacity at 5°F50% (higher)median 16,250 Btu/h44% (higher)median 18,800 Btu/h
Outdoor models2323
AHRI certifications2723

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardIWAEK&A
CEE 2025 Tier 1 (Split ASHP)34.8%8 models17.4%4 models
CEE 2026 Tier 1 (Split ASHP)34.8%8 models17.4%4 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)34.8%8 models17.4%4 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate26.1%6 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 6 groups where both have models
  • IWAE
  • K&A
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeIWAEK&A
Ducted, up to 1.5 tons1 · index —1 · index —
Ducted, 2 tons2 · index 37%4 · index 37%
Ducted, 2.5–3 tons3 · index 52%5 · index 26%
Ducted, 3.5–4.5 tons5 · index 41%9 · index 39%
Non-ducted, up to 1.5 tons8 · index 58%3 · index 13%
Non-ducted, 2 tons2 · index 65%1 · index 13%
Non-ducted, 2.5–3 tons2 · index —None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeIWAECold-climate score, best modelK&ACold-climate score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 1 models qualify)None on this board (0 of 1 models qualify)
Ducted, 2 tons42.5(50 is the typical model of its size class)**AESHV8T2421BAwith ducted air handler **AEAMPVT24D21BA1 of 2 models qualify · AHRI 21773289560.4(50 is the typical model of its size class) (higher)DIVINE-24K220V-7-Owith ducted air handler DIVINE-24K220V-7-I3 of 4 models qualify · AHRI 217656088
Ducted, 2.5–3 tons55.4(50 is the typical model of its size class)**AESHV9T3621BAwith ducted air handler **AEAMPVT36D21BA1 of 3 models qualify · AHRI 21773289659.2(50 is the typical model of its size class) (higher)DIVINE-36K220V-7-Owith ducted air handler DIVINE-36K220V-7-I1 of 5 models qualify · AHRI 217656089
Ducted, 3.5–4.5 tons43.2(50 is the typical model of its size class)**AESHV8T4821BAwith ducted air handler **AEAMPVT48F21BA2 of 5 models qualify · AHRI 21773289772.2(50 is the typical model of its size class) (higher)DIVINE-48K220V-7-Owith ducted air handler DIVINE-48K220V-7-I4 of 9 models qualify · AHRI 217656090
Non-ducted, up to 1.5 tons51.8(50 is the typical model of its size class)AEPL**MHV23S0932B1Awith ductless indoor unit AEPL**AWM23E0932B1A5 of 8 models qualify · AHRI 218451556None on this board (0 of 3 models qualify)
Non-ducted, 2 tons61.6(50 is the typical model of its size class)AEPL**MHV22S2431B1Awith ductless indoor unit AEPL**AWM22E2431B1A1 of 2 models qualify · AHRI 218451561None on this board (0 of 1 models qualify)
Non-ducted, 2.5–3 tonsNone on this board (0 of 2 models qualify)No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeIWAEAll-around score, best modelK&AAll-around score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 1 models have all five ratings)None on this board (0 of 1 models have all five ratings)
Ducted, 2 tons37.2(50 is the typical model of its size class)**AESHV8T2421BAwith ducted air handler **AEAMPVT24D21BA1 of 2 models have all five ratings · AHRI 21773289568.1(50 is the typical model of its size class) (higher)DIVINE-24K220V-7-Owith ducted air handler DIVINE-24K220V-7-I3 of 4 models have all five ratings · AHRI 217656088
Ducted, 2.5–3 tons51.6(50 is the typical model of its size class)**AESHV9T3621BAwith ducted air handler **AEAMPVT36D21BA1 of 3 models have all five ratings · AHRI 21773289657.5(50 is the typical model of its size class) (higher)DIVINE-36K220V-7-Owith ducted air handler DIVINE-36K220V-7-I3 of 5 models have all five ratings · AHRI 217656089
Ducted, 3.5–4.5 tons43.2(50 is the typical model of its size class)**AESHV8T4821BAwith ducted air handler **AEAMPVT48F21BA2 of 5 models have all five ratings · AHRI 21773289772.6(50 is the typical model of its size class) (higher)DIVINE-48K220V-7-Owith ducted air handler DIVINE-48K220V-7-I6 of 9 models have all five ratings · AHRI 217656090
Non-ducted, up to 1.5 tons63.4(50 is the typical model of its size class) (higher)AEPL**MHV23S1232B1Awith ductless indoor unit AEPL**AWM23E1232B1AAlso listed as AEPL**MHV23S1231B1A5 of 8 models have all five ratings · AHRI 21845155722.1(50 is the typical model of its size class)MAJESTIC-12K110V-S2with ductless indoor unit MAJESTIC-12K110V-S23 of 3 models have all five ratings · AHRI 216723132
Non-ducted, 2 tons64.8(50 is the typical model of its size class) (higher)AEPL**MHV22S2431B1Awith ductless indoor unit AEPL**AWM22E2431B1A1 of 2 models have all five ratings · AHRI 21845156113.4(50 is the typical model of its size class)MAJESTIC-24K220V-S2with ductless indoor unit MAJESTIC-24K220V-S21 of 1 models have all five ratings · AHRI 216723135
Non-ducted, 2.5–3 tonsNone on this board (0 of 2 models have all five ratings)No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingIWAEK&A
COP at 5°Fbeats 71% · 2.10AEPL**MHV22S2431B1ANon-ducted, 2 tonsbeats 86% · 2.30DIVINE-48K220V-7-ODucted, 3.5–4.5 tons
Capacity retention at 5°Fbeats 70% · 89%AEPL**MHV23S0932B1ANon-ducted, up to 1.5 tonsbeats 57% · 79%DIVINE-24K220V-7-ODucted, 2 tons
HSPF2beats 69% · 10.0AEPL**MHV22S2431B1ANon-ducted, 2 tonsbeats 74% · 9.2DIVINE-48K220V-7-ODucted, 3.5–4.5 tons
SEER2beats 82% · 19.0**AESHV9T3621BADucted, 2.5–3 tonsbeats 81% · 18.5DIVINE-48K220V-7-ODucted, 3.5–4.5 tons
EER2beats 70% · 13.0AEPL**MHV23S1232B1AAlso listed as AEPL**MHV23S1231B1ANon-ducted, up to 1.5 tonsbeats 81% · 12.5DIVINE-24K220V-7-ODucted, 2 tons
Heating capacity at 5°Fbeats 86% · 15,000 Btu/hAEPL**MHV22S1831B1ANon-ducted, up to 1.5 tonsbeats 68% · 40,000 Btu/hDIVINE-60K220V-7-ODucted, 3.5–4.5 tons

More comparisons