ALBOTT vs IWAE heat pumps
Measured against models of the same size and duct type, IWAE scores higher on 5 of the 6 ratings. ALBOTT has 23 outdoor models, IWAE has 23 outdoor models. ALBOTT and IWAE have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- ALBOTT
- IWAE
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | ALBOTT | IWAE |
|---|---|---|
| Efficiency index | 30%median — | 54%median — |
| COP at 5°F | 56% (higher)median 2.00 | 27% (higher)median 1.80 |
| Capacity retention at 5°F | 20%median 59% | 62%median 80% |
| HSPF2 | 20%median 8.2 | 36%median 8.0 |
| SEER2 | 28%median 18.1 | 41%median 17.0 |
| EER2 | 28%median 10.8 | 38%median 11.2 |
| Heating capacity at 5°F | 28%median 9,500 Btu/h | 51%median 16,250 Btu/h |
| Outdoor models | 23 | 23 |
| AHRI certifications | 23 | 27 |
Share of models meeting each standard
| Standard | ALBOTT | IWAE |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 52.2%12 models | 34.8%8 models |
| CEE 2026 Tier 1 (Split ASHP) | 52.2%12 models | 34.8%8 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 26.1%6 models | 34.8%8 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 8.7%2 models | 26.1%6 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- ALBOTT
- IWAE
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | ALBOTT | IWAE |
|---|---|---|
| Ducted, up to 1.5 tons | None | 1 · index — |
| Ducted, 2 tons | None | 2 · index 37% |
| Ducted, 2.5 to 3 tons | None | 3 · index 51% |
| Ducted, 3.5 to 4.5 tons | None | 5 · index 41% |
| Non-ducted, up to 1.5 tons | 16 · index 29% | 8 · index 60% |
| Non-ducted, 2 tons | 4 · index 33% | 2 · index 67% |
| Non-ducted, 2.5 to 3 tons | 3 · index 35% | 2 · index — |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | ALBOTTCold-climate score, best model | IWAECold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | None on this board (0 of 1 models qualify) |
| Ducted, 2 tons | No models in this size class | 42.0(50 is the typical model of its size class)**AESHV8T2421BAwith ducted air handler **AEAMPVT24D21BA1 of 2 models qualify · AHRI 217732895 |
| Ducted, 2.5 to 3 tons | No models in this size class | 55.0(50 is the typical model of its size class)**AESHV9T3621BAwith ducted air handler **AEAMPVT36D21BA1 of 3 models qualify · AHRI 217732896 |
| Ducted, 3.5 to 4.5 tons | No models in this size class | 43.3(50 is the typical model of its size class)**AESHV8T4821BAwith ducted air handler **AEAMPVT48F21BA2 of 5 models qualify · AHRI 217732897 |
| Non-ducted, up to 1.5 tons | 63.8(50 is the typical model of its size class) (higher)BI08W6-1B5A05 of 16 models qualify · AHRI 218087608 | 53.6(50 is the typical model of its size class)AEPL**MHV23S0932B1Awith ductless indoor unit AEPL**AWM23E0932B1A5 of 8 models qualify · AHRI 218451556 |
| Non-ducted, 2 tons | None on this board (0 of 4 models qualify) | 63.4(50 is the typical model of its size class)AEPL**MHV22S2431B1Awith ductless indoor unit AEPL**AWM22E2431B1A1 of 2 models qualify · AHRI 218451561 |
| Non-ducted, 2.5 to 3 tons | 55.9(50 is the typical model of its size class)BI08W6-1B6A01 of 3 models qualify · AHRI 218087609 | None on this board (0 of 2 models qualify) |
All-around best
| Size and duct type | ALBOTTAll-around score, best model | IWAEAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | None on this board (0 of 1 models have all five ratings) |
| Ducted, 2 tons | No models in this size class | 37.0(50 is the typical model of its size class)**AESHV8T2421BAwith ducted air handler **AEAMPVT24D21BA1 of 2 models have all five ratings · AHRI 217732895 |
| Ducted, 2.5 to 3 tons | No models in this size class | 51.4(50 is the typical model of its size class)**AESHV9T3621BAwith ducted air handler **AEAMPVT36D21BA1 of 3 models have all five ratings · AHRI 217732896 |
| Ducted, 3.5 to 4.5 tons | No models in this size class | 43.4(50 is the typical model of its size class)**AESHV8T4821BAwith ducted air handler **AEAMPVT48F21BA2 of 5 models have all five ratings · AHRI 217732897 |
| Non-ducted, up to 1.5 tons | 64.3(50 is the typical model of its size class)BI08W6-1B5A016 of 16 models have all five ratings · AHRI 218087608 | 65.3(50 is the typical model of its size class) (higher)AEPL**MHV23S1232B1Awith ductless indoor unit AEPL**AWM23E1232B1AAlso listed as AEPL**MHV23S1231B1A5 of 8 models have all five ratings · AHRI 218451557 |
| Non-ducted, 2 tons | 50.6(50 is the typical model of its size class)SAC-H220-24KOwith ductless indoor unit SAC-H220-24KI4 of 4 models have all five ratings · AHRI 216741385 | 67.0(50 is the typical model of its size class) (higher)AEPL**MHV22S2431B1Awith ductless indoor unit AEPL**AWM22E2431B1A1 of 2 models have all five ratings · AHRI 218451561 |
| Non-ducted, 2.5 to 3 tons | 52.4(50 is the typical model of its size class)BI08W6-1B6A03 of 3 models have all five ratings · AHRI 218087609 | None on this board (0 of 2 models have all five ratings) |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | ALBOTT | IWAE |
|---|---|---|
| COP at 5°F | beats 99% · 2.44BG21S5-1B5A2Also listed as SAC001-220V-36KONon-ducted, 2.5 to 3 tons | beats 70% · 2.10AEPL**MHV22S2431B1ANon-ducted, 2 tons |
| Capacity retention at 5°F | beats 84% · 98%SAC-B220-9KONon-ducted, up to 1.5 tons | beats 73% · 89%AEPL**MHV23S0932B1ANon-ducted, up to 1.5 tons |
| HSPF2 | beats 71% · 10.0SAC-H220-24KONon-ducted, 2 tons | beats 71% · 10.0AEPL**MHV22S2431B1ANon-ducted, 2 tons |
| SEER2 | beats 85% · 25.0BI08W6-1B5A0Non-ducted, up to 1.5 tons | beats 82% · 19.0**AESHV9T3621BADucted, 2.5 to 3 tons |
| EER2 | beats 56% · 12.0SAC-H220-24KONon-ducted, 2 tons | beats 73% · 13.0AEPL**MHV23S1232B1AAlso listed as AEPL**MHV23S1231B1ANon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 84% · 14,000 Btu/hBI08W6-1B5A0Non-ducted, up to 1.5 tons | beats 87% · 15,000 Btu/hAEPL**MHV22S1831B1ANon-ducted, up to 1.5 tons |