Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
LG heat pump efficiency: 78 outdoor models compared
LG has 78 heat pump outdoor models certified with this refrigerant group, in 175 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes LG makes. Ranks are among manufacturers with a QMID on file and at least 10 scored models.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 78
- AHRI certifications
- 175
- Efficiency index
- 65%
- Typical model vs same-size, same-type peers (102 models)
- Meet CEE 2025
- 74.4%
- 58 models
How LG compares with comparable models
- LG
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index102 models scored | 65% | 2nd of 27 | — |
| COP at 5°F105 models scored | 59% | 7th of 27 | 2.06 |
| Capacity retention at 5°F109 models scored | 64% | 5th of 27 | 80% |
| HSPF2111 models scored | 70% | 3rd of 27 | 9.5 |
| SEER2111 models scored | 63% | 6th of 27 | 20.2 |
| EER2111 models scored | 69% | 1st of 27 | 12.5 |
| Heating capacity at 5°F109 models scored | 67% | 3rd of 27 | 19,900 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 74.4% | 58 |
| CEE 2026 Tier 1 (Split ASHP) | 74.4% | 58 |
| CEE Advanced Tier (Split ASHP) | 9% | 7 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 67.9% | 53 |
| DOE Cold Climate Heat Pump Challenge | 9% | 7 |
| ENERGY STAR Cold Climate | 44.9% | 35 |
Sizes and duct types offered
- LG (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 11 | 57% | 58% | 53% | 41% |
| Ducted, 2 tons | 7 | 71% | 64% | 75% | 68% |
| Ducted, 2.5–3 tons | 9 | 80% | 66% | 79% | 77% |
| Ducted, 3.5–4.5 tons | 15 | 79% | 65% | 88% | 85% |
| Ducted, 5 tons and up | 3 | 72% | 40% | 99% | 87% |
| Non-ducted, up to 1.5 tons | 35 | 54% | 45% | 64% | 55% |
| Non-ducted, 2 tons | 10 | 61% | 61% | 63% | 60% |
| Non-ducted, 2.5–3 tons | 10 | 69% | 66% | 67% | 63% |
| Non-ducted, 3.5–4.5 tons | 11 | 70% | 79% | 72% | 53% |
| Non-ducted, 5 tons and up | 3 | 55% | 44% | 48% | 63% |
Every LG model in the market
- LG models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top LG models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1LMU421HHVLG | 3.5 tons42,000 Btu/h · Non-ducted | 100% | 2.29 | 11.0 | 48,000 | 21.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 206717001 | Non-ducted, 3.5–4.5 tons | 97.4 |
| 2ARUN038GSS4LG | 3 tons38,000 Btu/h · Ducted | 96% | 3.19 | 10.6 | 40,320 | 20.1 | CEE 25CEE 26XcelES CC | 3 | 8717932 | Ducted, 2.5–3 tons | 97.0 |
| 3LMU480HHVLG | 4 tons48,000 Btu/h · Non-ducted | 100% | 2.34 | 10.5 | 52,500 | 20.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 206717002 | Non-ducted, 3.5–4.5 tons | 95.8 |
| 4LAU090HYV3LG · LAU090HYV3with ductless indoor unit LAN090HYV3 | 1 ton9,000 Btu/h · Non-ducted | 100% | 3.13 | 13.5 | 11,000 | 27.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 204825177 | Non-ducted, up to 1.5 tons | 95.4 |
| 5LAU150HYV3LG · LAU150HYV3with ductless indoor unit LAN150HYV3 | 1.5 tons15,000 Btu/h · Non-ducted | 105% | 2.55 | 11.0 | 18,950 | 25.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 204825179 | Non-ducted, up to 1.5 tons | 93.2 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ARUN038GSS4LG | 3 tons38,000 Btu/h · Ducted | 96% | 3.19 | 10.6 | 20.1 | 14.0 | CEE 25CEE 26XcelES CC | 3 | 8717932 | Ducted, 2.5–3 tons | 97.5 | 97.0 | 98.0 | 97.0 |
| 2LAU090HYV3LG · LAU090HYV3with ductless indoor unit LAN090HYV3 | 1 ton9,000 Btu/h · Non-ducted | 100% | 3.13 | 13.5 | 27.0 | 15.8 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 204825177 | Non-ducted, up to 1.5 tons | 95.3 | 95.4 | 95.3 | 95.4 |
| 3LMU421HHVLG | 3.5 tons42,000 Btu/h · Non-ducted | 100% | 2.29 | 11.0 | 21.5 | 13.8 | CEE 25CEE 26CEE AdvXcelDOEES CC | 3 | 206717001 | Non-ducted, 3.5–4.5 tons | 92.1 | 97.4 | 86.7 | 97.4 |
| 4LAU150HYV3LG · LAU150HYV3with ductless indoor unit LAN150HYV3 | 1.5 tons15,000 Btu/h · Non-ducted | 105% | 2.55 | 11.0 | 25.0 | 15.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 204825179 | Non-ducted, up to 1.5 tons | 91.5 | 93.2 | 89.9 | 93.2 |
| 5LAU120HYV3LG · LAU120HYV3with ductless indoor unit LAN120HYV3 | 1 ton12,000 Btu/h · Non-ducted | 100% | 2.91 | 11.2 | 25.5 | 13.8 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 204825178 | Non-ducted, up to 1.5 tons | 89.8 | 92.6 | 87.0 | 92.6 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | ARUN038GSS4 | 3.19 | Non-ducted, 2.5–3 tons | 100% | 8717931 |
| Capacity retention at 5°F | ARUM036GSS5 | 114% | Non-ducted, 2.5–3 tons | 100% | 205967237 |
| HSPF2 | LMU601HV | 9.5 | Ducted, 5 tons and up | 99% | 206717003 |
| SEER2 | LMU601HV | 18.5 | Ducted, 5 tons and up | 99% | 206717003 |
| EER2 | ARUM036GSS5 | 15.5 | Non-ducted, 2.5–3 tons | 100% | 205967237 |
| Heating capacity at 5°F | ARUM036GSS5 | 48,000 Btu/h | Non-ducted, 2.5–3 tons | 100% | 205967237 |
LG size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 78.7(50 is the typical model of its size class)LUU090HVwith ducted air handler LHN098HV18 of 11 models qualify · AHRI 212578846 | 64.8(50 is the typical model of its size class)LUU180HHVwith ducted air handler LVN181HV48 of 11 models have all five ratings · AHRI 205788774 |
| Ducted, 2 tons | 92.9(50 is the typical model of its size class)ARUN024GSS45 of 7 models qualify · AHRI 10070563 | 86.9(50 is the typical model of its size class)ARUN024GSS46 of 7 models have all five ratings · AHRI 10070563 |
| Ducted, 2.5–3 tons | 97.0(50 is the typical model of its size class)ARUN038GSS47 of 9 models qualify · AHRI 8717932 | 97.5(50 is the typical model of its size class)ARUN038GSS48 of 9 models have all five ratings · AHRI 8717932 |
| Ducted, 3.5–4.5 tons | 86.4(50 is the typical model of its size class)LMU480HHV12 of 15 models qualify · AHRI 206717009 | 89.8(50 is the typical model of its size class)LMU480HHV15 of 15 models have all five ratings · AHRI 206717009 |
| Ducted, 5 tons and up | 81.7(50 is the typical model of its size class)LMU601HV2 of 3 models qualify · AHRI 206717003 | 78.9(50 is the typical model of its size class)LMU601HV2 of 3 models have all five ratings · AHRI 206717003 |
| Non-ducted, up to 1.5 tons | 95.4(50 is the typical model of its size class)LAU090HYV3with ductless indoor unit LAN090HYV322 of 35 models qualify · AHRI 204825177 | 95.3(50 is the typical model of its size class)LAU090HYV3with ductless indoor unit LAN090HYV331 of 35 models have all five ratings · AHRI 204825177 |
| Non-ducted, 2 tons | 92.9(50 is the typical model of its size class)ARUN024GSS47 of 10 models qualify · AHRI 10070562 | 88.3(50 is the typical model of its size class)LAU240HYV3with ductless indoor unit LAN240HYV39 of 10 models have all five ratings · AHRI 204825181 |
| Non-ducted, 2.5–3 tons | 92.2(50 is the typical model of its size class)ARUN038GSS47 of 10 models qualify · AHRI 8717931 | 87.4(50 is the typical model of its size class)LMU361HHV10 of 10 models have all five ratings · AHRI 206717007 |
| Non-ducted, 3.5–4.5 tons | 97.4(50 is the typical model of its size class)LMU421HHV8 of 11 models qualify · AHRI 206717001 | 92.1(50 is the typical model of its size class)LMU421HHV11 of 11 models have all five ratings · AHRI 206717001 |
| Non-ducted, 5 tons and up | 71.5(50 is the typical model of its size class)ARUB060GSS43 of 3 models qualify · AHRI 10271659 | 61.0(50 is the typical model of its size class)LMU601HV3 of 3 models have all five ratings · AHRI 206717015 |
Newest LG certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| LUU360HVLGwith ducted air handler H,GG1K936+TD | 3 tons35,000 Btu/h · Ducted and non-ducted | 1.80 | 94% | 9.0 | 15.2 | CEE 25CEE 26XcelES CC | 9 | 217037732 |
| LUU240HVLGwith ducted air handler H,GG8J924+TD | 2 tons26,600 Btu/h · Ducted and non-ducted | 1.80 | 91% | 8.0 | 14.5 | CEE 25CEE 26XcelES CC | 7 | 217037731 |
| LUU601HVLG · LUU601HVwith ducted air handler LVN600HV | 4.5 tons52,500 Btu/h · Ducted | 1.80 | 73% | 9.2 | 16.5 | CEE 25CEE 26XcelES CC | 3 | 213361981 |
| LUU420HVLGwith indoor coil C74B(A,H)MX48C-C and furnace FG7TC100D-V35C | 3.5 tons42,000 Btu/h · Ducted and non-ducted | 1.82 | 84% | 9.3 | 17.2 | CEE 25CEE 26XcelES CC | 4 | 213307889 |
| LUU180HVLGwith indoor coil C74B(A,H)MX24C-B and furnace FG7TC060D-V24B | 1.5 tons18,000 Btu/h · Ducted and non-ducted | 1.84 | 86% | 9.1 | 17.5 | CEE 25CEE 26XcelES CC | 4 | 213307887 |
Compare LG