Both views use the same certified data. This device remembers your choice.
Midea heat pump efficiency: 408 outdoor models compared
Midea has 408 heat pump outdoor models certified with this refrigerant group, in 1,554 AHRI-certified combinations. They are also sold as CTMorley, MDV. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Midea makes. Ranks are among manufacturers with a QMID on file and at least 10 scored models.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 408
- AHRI certifications
- 1,554
- Efficiency index
- 55%
- Typical model vs same-size, same-type peers (544 models)
- Meet CEE 2025
- 60.3%
- 246 models
How Midea compares with comparable models
- Midea
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index544 models scored | 55% | 12th of 27 | — |
| COP at 5°F544 models scored | 49% | 19th of 27 | 1.93 |
| Capacity retention at 5°F544 models scored | 52% | 16th of 27 | 69% |
| HSPF2569 models scored | 63% | 9th of 27 | 9.2 |
| SEER2569 models scored | 58% | 9th of 27 | 19.0 |
| EER2569 models scored | 47% | 19th of 27 | 11.0 |
| Heating capacity at 5°F544 models scored | 53% | 15th of 27 | 20,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 60.3% | 246 |
| CEE 2026 Tier 1 (Split ASHP) | 57.4% | 234 |
| CEE Advanced Tier (Split ASHP) | 2.7% | 11 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 45.1% | 184 |
| DOE Cold Climate Heat Pump Challenge | 2.7% | 11 |
| ENERGY STAR Cold Climate | 37.3% | 152 |
Sizes and duct types offered
- Midea (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 48 | 60% | 50% | 69% | 64% |
| Ducted, 2 tons | 34 | 59% | 43% | 73% | 64% |
| Ducted, 2.5 to 3 tons | 100 | 55% | 39% | 70% | 65% |
| Ducted, 3.5 to 4.5 tons | 67 | 56% | 40% | 77% | 62% |
| Ducted, 5 tons and up | 21 | 49% | 41% | 67% | 57% |
| Non-ducted, up to 1.5 tons | 122 | 54% | 61% | 60% | 54% |
| Non-ducted, 2 tons | 31 | 54% | 59% | 55% | 57% |
| Non-ducted, 2.5 to 3 tons | 95 | 55% | 52% | 52% | 56% |
| Non-ducted, 3.5 to 4.5 tons | 50 | 49% | 48% | 49% | 47% |
| Non-ducted, 5 tons and up | 1 | 10% | 3% | 6% | 10% |
Every Midea model in the market
- Midea models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 179 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 354 | 1.85 | 1.89 | 2.00 | 2.40 | 2.63 |
| Ducted, 1.5 tons | 802 | 1.75 | 1.85 | 2.00 | 2.20 | 2.52 |
| Ducted, 2 tons | 791 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 758 | 1.70 | 1.80 | 1.90 | 2.10 | 2.44 |
| Ducted, 3 tons | 674 | 1.68 | 1.73 | 1.90 | 2.06 | 2.34 |
| Ducted, 3.5 tons | 662 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 373 | 1.70 | 1.80 | 1.91 | 2.02 | 2.50 |
| Ducted, 4.5 tons | 575 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 29 | 1.80 | 1.80 | 1.86 | 1.90 | 2.10 |
| Non-ducted, 0.5 tons | 774 | 1.75 | 1.80 | 1.94 | 2.09 | 2.19 |
| Non-ducted, 1 ton | 1,135 | 1.75 | 1.80 | 1.89 | 2.07 | 2.24 |
| Non-ducted, 1.5 tons | 946 | 1.75 | 1.80 | 1.87 | 2.07 | 2.20 |
| Non-ducted, 2 tons | 598 | 1.78 | 1.80 | 1.83 | 2.00 | 2.21 |
| Non-ducted, 2.5 tons | 327 | 1.75 | 1.80 | 1.84 | 1.86 | 2.02 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.80 | 1.90 | 2.00 | 2.07 |
| Non-ducted, 3.5 tons | 71 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 269 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 106 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 31 | 1.89 | 2.00 | 2.07 | 2.30 | 2.40 |
Source: AHRI Directory · as of
Midea in the cold
- All listed models (median, middle 50% and 80%)
- Midea (median, middle 50%)
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 3,710 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 3,710 | 65% | 68% | 76% | 83% | 92% |
| All rated models, 5°F | 3,710 | 55% | 58% | 66% | 75% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 3,710 | 2.64 | 2.87 | 3.1 | 3.32 | 3.53 |
| All rated models, 17°F | 3,710 | 1.98 | 2.05 | 2.2 | 2.34 | 2.49 |
| All rated models, 5°F | 3,710 | 1.8 | 1.83 | 1.92 | 2.03 | 2.21 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Midea, 47°F | 239 | 100% | 100% | 100% | 100% | 100% |
| Midea, 17°F | 239 | 64% | 67% | 72% | 79% | 84% |
| Midea, 5°F | 239 | 55% | 57% | 63% | 73% | 82% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Midea, 47°F | 239 | 2.64 | 2.87 | 3.09 | 3.27 | 3.47 |
| Midea, 17°F | 239 | 1.9 | 2.05 | 2.2 | 2.3 | 2.45 |
| Midea, 5°F | 239 | 1.8 | 1.83 | 1.97 | 2.02 | 2.18 |
Source: NEEP ccASHP list · as of
Top Midea models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1MOX230-09HFN1-MY2WMDV · MFA serieswith ductless indoor unit MFA2U-09HRFN1-MY6W | 1 ton9,000 Btu/h · Non-ducted | 96% | 2.45 | 12.5 | 8,600 | 25.6 | CEE 25CEE 26XcelES CC | 1 | 209248925 | Non-ducted, up to 1.5 tons | 92.7 |
| 2M4OX630-36HFN1-M1X*MDV · MSEP seris | 3 tons36,000 Btu/h · Non-ducted | 103% | 2.00 | 10.9 | 37,000 | 22.4 | CEE 25CEE 26XcelES CC | 3 | 213301877 | Non-ducted, 2.5 to 3 tons | 91.3 |
| 3MOX230-09HFN1-MW5W-LMDV · MSEP seriswith ductless indoor unit MSEPB-06HRFN1-MY5W | 0.5 tons6,000 Btu/h · Non-ducted | 107% | 2.10 | 13.6 | 7,500 | 26.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 213199198 | Non-ducted, up to 1.5 tons | 90.7 |
| 4MOX330-09HFN1-MY6WMDV · MFA serieswith ductless indoor unit MFA2U-09HRFN1-MY6W | 1 ton9,000 Btu/h · Non-ducted | 137% | 2.10 | 11.4 | 12,300 | 26.3 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 209248923 | Non-ducted, up to 1.5 tons | 90.1 |
| 538MARBQ06AA3MIDEA · 38MAR-serieswith ductless indoor unit DHMAHBQ06XA3Also sold as MDV MOX230-09HFN1-MW5W; also listed as DLCSRBH06AAK | 0.5 tons6,000 Btu/h · Non-ducted | 107% | 2.09 | 13.6 | 7,500 | 26.5 | CEE 25CEE 26XcelES CC | 2 | 207188936 | Non-ducted, up to 1.5 tons | 89.8 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1MOX230-09HFN1-MW5W-LMDV · MSEP seriswith ductless indoor unit MSEPB-06HRFN1-MY5W | 0.5 tons6,000 Btu/h · Non-ducted | 107% | 2.10 | 13.6 | 26.5 | 15.8 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 213199198 | Non-ducted, up to 1.5 tons | 92.7 | 90.7 | 94.7 | 90.7 |
| 238MARBQ06AA3MIDEA · 38MAR-serieswith ductless indoor unit DHMAHBQ06XA3Also sold as MDV MOX230-09HFN1-MW5W; also listed as DLCSRBH06AAK | 0.5 tons6,000 Btu/h · Non-ducted | 107% | 2.09 | 13.6 | 26.5 | 15.8 | CEE 25CEE 26XcelES CC | 2 | 207188936 | Non-ducted, up to 1.5 tons | 92.3 | 89.8 | 94.7 | 89.8 |
| 3MOX230-09HFN1-MY2WMDV · MFA serieswith ductless indoor unit MFA2U-09HRFN1-MY6W | 1 ton9,000 Btu/h · Non-ducted | 96% | 2.45 | 12.5 | 25.6 | 14.7 | CEE 25CEE 26XcelES CC | 1 | 209248925 | Non-ducted, up to 1.5 tons | 91.9 | 92.7 | 91.1 | 92.7 |
| 4MOX330-09HFN1-MY6WMDV · MFA serieswith ductless indoor unit MFA2U-09HRFN1-MY6W | 1 ton9,000 Btu/h · Non-ducted | 137% | 2.10 | 11.4 | 26.3 | 15.7 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 209248923 | Non-ducted, up to 1.5 tons | 91.7 | 90.1 | 93.3 | 90.1 |
| 5MOX430-09HFN1-MZG5WMDV · MSEP seriswith ductless indoor unit MSEPC-09HRFN1-MZB5W | 1 ton9,000 Btu/h · Non-ducted | 113% | 1.86 | 14.0 | 29.0 | 16.5 | CEE 25CEE 26XcelES CC | 5 | 207591143 | Non-ducted, up to 1.5 tons | 89.3 | 79.6 | 99.0 | 79.6 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | MOX230-09HFN1-MY2W | 2.45 | Non-ducted, up to 1.5 tons | 98% | 209248925 |
| Capacity retention at 5°F | MOX330-09HFN1-MY6W | 137% | Non-ducted, up to 1.5 tons | 99% | 209248923 |
| HSPF2 | 38MPRBQ09AA3Also sold as MDV MOX430-09HFN1-MZG5W; also listed as DLCPRBH09AAK | 15.0 | Non-ducted, up to 1.5 tons | 100% | 213214839 |
| SEER2 | 38MGHBQ30DA3Also sold as MDV M4OG-30HFN1-M; also listed as MMCMHAQ30DA3 | 26.0 | Non-ducted, 2.5 to 3 tons | 100% | 207642966 |
| EER2 | MOX430-09HFN1-MZG5W | 16.5 | Non-ducted, up to 1.5 tons | 99% | 207591143 |
| Heating capacity at 5°F | MOE30U-32HFN1-M-[X] | 46,000 Btu/h | Ducted, 2.5 to 3 tons | 100% | 205823026 |
Midea size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 87.0(50 is the typical model of its size class)MOX430U-18HFN1-Mwith ducted air handler MVBE-18HWFN1-MM3E41 of 49 models qualify · AHRI 213156951 | 85.4(50 is the typical model of its size class)38MARBQ09AA3with ducted air handler 40MBDQ09---3Also sold as MDV MOX330-09HFN1-MY5W, CTMorley MOU-A09H-2; also listed as DLCSRBH09AAK51 of 51 models have all five ratings · AHRI 206350372 |
| Ducted, 2 tons | 80.6(50 is the typical model of its size class)MOD33-24HFN1-MT0Wwith ducted air handler MTIU-24HWFN1-M30 of 33 models qualify · AHRI 206330133 | 84.0(50 is the typical model of its size class)MOD33-24HFN1-MT0Wwith ducted air handler MTIU-24HWFN1-M31 of 31 models have all five ratings · AHRI 206330133 |
| Ducted, 2.5 to 3 tons | 84.7(50 is the typical model of its size class)MOE30U-32HFN1-M-[X]with ducted air handler MTI-32HWFN1-M49 of 101 models qualify · AHRI 205823026 | 83.7(50 is the typical model of its size class)M4OX630-36HFN1-M1XAlso listed as M4OX630-36HFN1-M1X95 of 100 models have all five ratings · AHRI 213301875 |
| Ducted, 3.5 to 4.5 tons | 86.5(50 is the typical model of its size class)MOE30U-48HFN1-M-[X]with ducted air handler MTI-48HWFN1-MAlso sold as CTMorley MOU-A48LH-2; also listed as MOE30U-48HFN1-M-[X](GA)34 of 66 models qualify · AHRI 204829821 | 84.7(50 is the typical model of its size class)M5OG-42HFN1-M-[X]61 of 67 models have all five ratings · AHRI 207617659 |
| Ducted, 5 tons and up | 70.2(50 is the typical model of its size class)MRB-60HWD1N1-M19Also listed as MRD-60HWD1N1-M182 of 21 models qualify · AHRI 202680577 | 75.5(50 is the typical model of its size class)MRB-60HWD1N1-M19Also listed as MRD-60HWD1N1-M1820 of 21 models have all five ratings · AHRI 202680577 |
| Non-ducted, up to 1.5 tons | 92.7(50 is the typical model of its size class)MOX230-09HFN1-MY2Wwith ductless indoor unit MFA2U-09HRFN1-MY6W58 of 122 models qualify · AHRI 209248925 | 92.7(50 is the typical model of its size class)MOX230-09HFN1-MW5W-Lwith ductless indoor unit MSEPB-06HRFN1-MY5W119 of 122 models have all five ratings · AHRI 213199198 |
| Non-ducted, 2 tons | 87.1(50 is the typical model of its size class)38MARBQ24AA3with ductless indoor unit 40MBCAQ24XA3Also sold as MDV MOD30-24HFN1-MU0W, CTMorley MOU-A24H-2, MDV MOD30-24HFN1-MU0W-L; also listed as DLCSRBH24AAK18 of 31 models qualify · AHRI 207683320 | 84.9(50 is the typical model of its size class)38MARBQ24AA3with ductless indoor unit DHMAHBQ24XA3Also sold as MDV MOD30-24HFN1-MU0W, MDV MOD30-24HFN1-MU0W-L; also listed as DLCSRBH24AAK31 of 31 models have all five ratings · AHRI 206350321 |
| Non-ducted, 2.5 to 3 tons | 91.3(50 is the typical model of its size class)M4OX630-36HFN1-M1X*31 of 95 models qualify · AHRI 213301877 | 86.7(50 is the typical model of its size class)M4OX630-36HFN1-M1X*85 of 95 models have all five ratings · AHRI 213301877 |
| Non-ducted, 3.5 to 4.5 tons | 87.6(50 is the typical model of its size class)M5OG-42HFN1-M-[X]with ductless indoor unit MSEPB-09HRFN1-MY5W(GA)29 of 50 models qualify · AHRI 207617657 | 85.9(50 is the typical model of its size class)M5OG-42HFN1-M-[X]with ductless indoor unit MSEPB-09HRFN1-MY5W(GA)47 of 50 models have all five ratings · AHRI 207617657 |
| Non-ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 10.0(50 is the typical model of its size class)MDV-V60WMN1T*1 of 1 models have all five ratings · AHRI 212604264 |
Newest Midea certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| 38MURAQ30AB3MIDEAwith ducted air handler HE31930+TD | 2.5 tons28,600 Btu/h · Ducted | 1.76 | 89% | 9.1 | 15.2 | CEE 25CEE 26XcelES CC | 12 | 218748125 |
| 38MURAQ24AB3MIDEAwith ducted air handler HE30924+TD | 2 tons24,000 Btu/h · Ducted | 1.88 | 82% | 9.1 | 16.0 | CEE 25CEE 26XcelES CC | 10 | 218748124 |
| DLCURAH36ACKMIDEA · DLC Serieswith ducted air handler DLFUAAH36XAK | 3 tons35,000 Btu/h · Ducted | 1.80 | 97% | 9.5 | 16.3 | CEE 25CEE 26XcelES CC | 3 | 217902700 |
| 38MURAQ60AB3MIDEA · 38M Serieswith ducted air handler DLFUAAH60XAK | 4.5 tons55,000 Btu/h · Ducted | 1.91 | 82% | 9.4 | 15.3 | ES CC | 5 | 217622253 |
| 38MURAQ48AB3MIDEA · 38M Serieswith ducted air handler DLFUAAH48XAK | 4 tons47,000 Btu/h · Ducted | 1.90 | 92% | 9.4 | 15.6 | ES CC | 4 | 217622252 |
Compare Midea
Midea includes these brand names as listed in AHRI: CTMorley, MDV, MIDEA. Standards are checked against published thresholds; program rules beyond ratings are not checked.