Skip to content

Savaire heat pumps: how do their ratings compare?

A typical Savaire heat pump beats 17% of similar heat pumps (same size and type), which is well below average. Savaire has 7 heat pump models in this list.

Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated

Overall score

17%

of similar heat pumps beaten by its typical model

Well below average

Savaire has no QMID (the manufacturer ID the 25C tax credit needs) on file, so it is not ranked against other brands. Based on 7 models with every rating.

Savaire, rating by ratingStrongest on hot-day cooling efficiency (beats 29%), weakest on efficiency on a 5°f day (beats 8%).
  • Efficiency on a 5°F dayCOP at 5°FBeats 8%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FBeats 22%
  • Winter-long heating efficiencyHSPF2Beats 13%
  • Summer-long cooling efficiencySEER2Beats 10%
  • Hot-day cooling efficiencyEER2Beats 29%

Average (50%)

Each bar: the share of similar heat pumps a typical model beats on that rating.

Rebate standards

Share of this brand’s models that meet the efficiency levels rebate programs use. Programs can have other rules too.
  • 29%

    meet CEE 2025 Tier 1, the level many utility rebates use.

    2 models. All brands: 49%.

    See them

  • 0%

    meet Xcel Energy Colorado’s cold-climate rebate levels.

    0 models. All brands: 38%.

    See them

  • 0%

    reach the cold-climate tier: full heating output and a COP of 2.1 or more at 5°F.

    None of its models. All brands: 1%.

Savaire all-around best, by size

Showing Ductless, Up to 1.5 tons (under 21,000 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?

5 of Savaire’s 5 models of this size and type have all five ratings.

  1. 1VOC9H1with ductless indoor unit VSC9H1Savaire1 ton · 9,000 Btu/h · DuctlessNot a cold-climate pick: keeps 64% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    64% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.75 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.0 (HSPF2)
    Below the middle
    Cooling efficiency
    18.5 (SEER2)
    Below the middle
    Hot-day cooling
    11.1 (EER2)
    Below the middle
    19.0score / 100Heating 12 · Cooling 26
  2. 2VOC18H2with ductless indoor unit VSC18H2Savaire1.5 tons · 18,000 Btu/h · DuctlessNot a cold-climate pick: keeps 66% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    66% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.75 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.0 (HSPF2)
    Below the middle
    Cooling efficiency
    17.0 (SEER2)
    Below the middle
    Hot-day cooling
    10.6 (EER2)
    Below the middle
    15.1score / 100Heating 14 · Cooling 16
  3. 3VOC12H2with ductless indoor unit VSC12H2Savaire1 ton · 12,000 Btu/h · DuctlessNot a cold-climate pick: keeps 66% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    67% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.75 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.0 (HSPF2)
    Below the middle
    Cooling efficiency
    16.0 (SEER2)
    Below the middle
    Hot-day cooling
    10.5 (EER2)
    Below the middle
    14.6score / 100Heating 16 · Cooling 13
  4. 4VOC12H1with ductless indoor unit VSC12H1Savaire1 ton · 12,000 Btu/h · DuctlessNot a cold-climate pick: keeps 66% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    67% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.75 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.0 (HSPF2)
    Below the middle
    Cooling efficiency
    17.5 (SEER2)
    Below the middle
    Hot-day cooling
    10.0 (EER2)
    Below the middle
    14.2score / 100Heating 16 · Cooling 12
  5. 5VOC9H2with ductless indoor unit VSC9H2Savaire1 ton · 9,000 Btu/h · DuctlessNot a cold-climate pick: keeps 57% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    58% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.75 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.0 (HSPF2)
    Below the middle
    Cooling efficiency
    16.0 (SEER2)
    Below the middle
    Hot-day cooling
    10.9 (EER2)
    Below the middle
    12.5score / 100Heating 9 · Cooling 16

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.