TEMP SHIFT heat pump efficiency: 28 outdoor models compared
TEMP SHIFT has 28 heat pump outdoor models certified with this refrigerant group, in 66 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes TEMP SHIFT makes. TEMP SHIFT has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 28
- AHRI certifications
- 66
- Efficiency index
- 59%
- Typical model vs same-size, same-type peers (38 models)
- Meet CEE 2025
- 67.9%
- 19 models
How TEMP SHIFT compares with comparable models
- TEMP SHIFT
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index38 models scored | 59% | Not ranked | — |
| COP at 5°F38 models scored | 47% | Not ranked | 1.91 |
| Capacity retention at 5°F38 models scored | 73% | Not ranked | 84% |
| HSPF238 models scored | 74% | Not ranked | 9.6 |
| SEER238 models scored | 60% | Not ranked | 17.5 |
| EER238 models scored | 47% | Not ranked | 10.6 |
| Heating capacity at 5°F38 models scored | 69% | Not ranked | 25,400 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 67.9% | 19 |
| CEE 2026 Tier 1 (Split ASHP) | 64.3% | 18 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 67.9% | 19 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- TEMP SHIFT (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 6 | 57% | 38% | 63% | 64% |
| Ducted, 2 tons | 3 | 59% | 54% | 85% | 63% |
| Ducted, 2.5–3 tons | 8 | 57% | 45% | 78% | 54% |
| Ducted, 3.5–4.5 tons | 6 | 57% | 45% | 80% | 69% |
| Non-ducted, up to 1.5 tons | 5 | 70% | 42% | 78% | 69% |
| Non-ducted, 2 tons | 1 | 66% | 63% | 100% | 58% |
| Non-ducted, 2.5–3 tons | 6 | 58% | 56% | 62% | 54% |
| Non-ducted, 3.5–4.5 tons | 3 | 53% | 46% | 74% | 41% |
Every TEMP SHIFT model in the market
- TEMP SHIFT models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top TEMP SHIFT models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1TSM4OX63036HFN1M1XTEMP SHIFT | 3 tons36,000 Btu/h · Non-ducted | 100% | 1.95 | 10.9 | 36,000 | 21.0 | CEE 25CEE 26Xcel | 3 | 213479395 | Non-ducted, 2.5–3 tons | 87.0 |
| 2TSMOD3024HFN1MU0WTEMP SHIFTwith ductless indoor unit TSMCD124HRFN1MT0W(GA) | 2 tons24,000 Btu/h · Non-ducted | 103% | 2.00 | 11.5 | 25,800 | 20.5 | CEE 25CEE 26Xcel | 3 | 213479382 | Non-ducted, 2 tons | 86.1 |
| 3TSM5OG48HFN1M[X]TEMP SHIFT | 4 tons48,000 Btu/h · Non-ducted | 92% | 2.00 | 10.0 | 45,000 | 21.2 | CEE 25CEE 26Xcel | 3 | 213479398 | Non-ducted, 3.5–4.5 tons | 80.5 |
| 4TSM3OK27HFN1MTEMP SHIFT | 2.5 tons27,000 Btu/h · Ducted | 101% | 1.90 | 10.0 | 27,200 | 19.0 | CEE 25CEE 26Xcel | 3 | 213479393 | Ducted, 2.5–3 tons | 80.4 |
| 5TSM4OX63036HFN1M1XTEMP SHIFT | 3 tons36,000 Btu/h · Ducted | 100% | 1.90 | 10.0 | 36,000 | 19.4 | CEE 25CEE 26Xcel | 3 | 213479396 | Ducted, 2.5–3 tons | 79.9 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1TSMOX33009HFN1MY5WTEMP SHIFTwith ducted air handler TSMTIU09HWFN1M | 1 ton9,000 Btu/h · Ducted | 108% | 1.90 | 12.0 | 20.2 | 13.2 | CEE 25CEE 26Xcel | 3 | 213479385 | Ducted, up to 1.5 tons | 85.2 | 74.9 | 95.5 | 74.9 |
| 2TSMOX33009HFN1MY5WTEMP SHIFTwith ductless indoor unit TSMSAG11B09HRFN1MX7W(GA) | 1 ton9,000 Btu/h · Non-ducted | 94% | 1.90 | 11.6 | 26.4 | 15.8 | CEE 25CEE 26Xcel | 3 | 216014856 | Non-ducted, up to 1.5 tons | 84.4 | 74.8 | 94.1 | 74.8 |
| 3TSM4OX63036HFN1M1XTEMP SHIFT | 3 tons36,000 Btu/h · Ducted | 100% | 1.90 | 10.0 | 19.4 | 12.0 | CEE 25CEE 26Xcel | 3 | 213479396 | Ducted, 2.5–3 tons | 83.7 | 79.9 | 87.5 | 79.9 |
| 4TSM5OG48HFN1M[X]TEMP SHIFT | 4 tons47,000 Btu/h · Ducted | 87% | 2.00 | 9.0 | 20.9 | 11.7 | CEE 25CEE 26Xcel | 3 | 213479399 | Ducted, 3.5–4.5 tons | 82.0 | 74.9 | 89.1 | 74.9 |
| 5TSM3OK27HFN1MTEMP SHIFT | 2.5 tons27,000 Btu/h · Ducted | 101% | 1.90 | 10.0 | 19.0 | 11.8 | CEE 25CEE 26Xcel | 3 | 213479393 | Ducted, 2.5–3 tons | 81.9 | 80.4 | 83.3 | 80.4 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | TSMOD3136HFN1MP0W | 2.01 | Non-ducted, 2.5–3 tons | 87% | 216014861 |
| Capacity retention at 5°F | TSM3OK27HFN1M | 101% | Ducted, 2.5–3 tons | 96% | 213479393 |
| HSPF2 | TSMOX33009HFN1MY5W | 12.0 | Ducted, up to 1.5 tons | 98% | 213479385 |
| SEER2 | TSM5OG48HFN1M[X] | 20.9 | Ducted, 3.5–4.5 tons | 99% | 213479399 |
| EER2 | TSMOX33009HFN1MY5W | 15.8 | Non-ducted, up to 1.5 tons | 95% | 216014856 |
| Heating capacity at 5°F | TSMOE30U36HFN1M(GA) | 41,000 Btu/h | Non-ducted, 2.5–3 tons | 98% | 213479383 |
TEMP SHIFT size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 74.9(50 is the typical model of its size class)TSMOX33009HFN1MY5Wwith ducted air handler TSMTIU09HWFN1M5 of 6 models qualify · AHRI 213479385 | 85.2(50 is the typical model of its size class)TSMOX33009HFN1MY5Wwith ducted air handler TSMTIU09HWFN1M6 of 6 models have all five ratings · AHRI 213479385 |
| Ducted, 2 tons | 79.4(50 is the typical model of its size class)TSMOD3024HFN1MU0Wwith ducted air handler TSMTIU24HWFN1M3 of 3 models qualify · AHRI 213479388 | 80.1(50 is the typical model of its size class)TSMOD3024HFN1MU0Wwith ducted air handler TSMTIU24HWFN1M3 of 3 models have all five ratings · AHRI 213479388 |
| Ducted, 2.5–3 tons | 80.4(50 is the typical model of its size class)TSM3OK27HFN1M6 of 8 models qualify · AHRI 213479393 | 83.7(50 is the typical model of its size class)TSM4OX63036HFN1M1X8 of 8 models have all five ratings · AHRI 213479396 |
| Ducted, 3.5–4.5 tons | 74.9(50 is the typical model of its size class)TSM5OG48HFN1M[X]4 of 6 models qualify · AHRI 213479399 | 82.0(50 is the typical model of its size class)TSM5OG48HFN1M[X]5 of 5 models have all five ratings · AHRI 213479399 |
| Ducted, 5 tons and up | No models in this size class | 41.7(50 is the typical model of its size class)TSMOE30U60HFN1MR0with ducted air handler TSMVC60HWFN1M1 of 1 models have all five ratings · AHRI 212925591 |
| Non-ducted, up to 1.5 tons | 74.8(50 is the typical model of its size class)TSMOX33009HFN1MY5Wwith ductless indoor unit TSMSAG11B09HRFN1MX7W(GA)5 of 5 models qualify · AHRI 216014856 | 84.4(50 is the typical model of its size class)TSMOX33009HFN1MY5Wwith ductless indoor unit TSMSAG11B09HRFN1MX7W(GA)5 of 5 models have all five ratings · AHRI 216014856 |
| Non-ducted, 2 tons | 86.1(50 is the typical model of its size class)TSMOD3024HFN1MU0Wwith ductless indoor unit TSMCD124HRFN1MT0W(GA)1 of 1 models qualify · AHRI 213479382 | 70.7(50 is the typical model of its size class)TSMOD3024HFN1MU0Wwith ductless indoor unit TSMSAG11D23HRFN1MU0W1 of 1 models have all five ratings · AHRI 216014859 |
| Non-ducted, 2.5–3 tons | 87.0(50 is the typical model of its size class)TSM4OX63036HFN1M1X4 of 6 models qualify · AHRI 213479395 | 76.8(50 is the typical model of its size class)TSM4OX63036HFN1M1X6 of 6 models have all five ratings · AHRI 213479395 |
| Non-ducted, 3.5–4.5 tons | 80.5(50 is the typical model of its size class)TSM5OG48HFN1M[X]3 of 3 models qualify · AHRI 213479398 | 73.8(50 is the typical model of its size class)TSM5OG48HFN1M[X]3 of 3 models have all five ratings · AHRI 213479398 |
Newest TEMP SHIFT certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| TSMOD3136HFN1MP0WTEMP SHIFTwith ductless indoor unit TSMSAGF36HRFNXMR0W | 3 tons36,000 Btu/h · Non-ducted | 2.01 | 61% | 7.8 | 18.0 | None | 1 | 216014861 |
| TSMOD3030HFN1MS0WTEMP SHIFTwith ductless indoor unit TSMSAGF30HRFN1MT0W | 2.5 tons30,000 Btu/h · Non-ducted | 1.86 | 61% | 8.2 | 21.0 | CEE 25CEE 26 | 1 | 216014860 |
| TSMOD3024HFN1MU0WTEMP SHIFTwith ductless indoor unit TSMSAG11D23HRFN1MU0W | 2 tons23,000 Btu/h · Ducted and non-ducted | 1.80 | 88% | 10.3 | 22.3 | CEE 25CEE 26Xcel | 3 | 216014859 |
| TSMOX43017HFN1MT0WTEMP SHIFTwith ductless indoor unit TSMSAG11D18HRFN1MT8W | 1.5 tons18,000 Btu/h · Ducted and non-ducted | 1.89 | 96% | 10.6 | 22.0 | CEE 25CEE 26Xcel | 3 | 216014858 |
| TSMOX33012HFN1MW5WTEMP SHIFTwith ductless indoor unit TSMSAG11B12HRFN1MV0W(GA) | 1 ton12,000 Btu/h · Ducted and non-ducted | 1.89 | 92% | 10.5 | 23.1 | CEE 25CEE 26Xcel | 3 | 216014857 |
Compare TEMP SHIFT
TEMP SHIFT includes these brand names as listed in AHRI: TEMP SHIFT. Standards are checked against published thresholds; program rules beyond ratings are not checked.