THERMAL ZONE heat pump efficiency: 88 outdoor models compared
THERMAL ZONE has 88 heat pump outdoor models certified with this refrigerant group, in 509 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes THERMAL ZONE makes. THERMAL ZONE has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 88
- AHRI certifications
- 509
- Efficiency index
- 43%
- Typical model vs same-size, same-type peers (35 models)
- Meet CEE 2025
- 12.5%
- 11 models
How THERMAL ZONE compares with comparable models
- THERMAL ZONE
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index35 models scored | 43% | Not ranked | — |
| COP at 5°F35 models scored | 68% | Not ranked | 2.10 |
| Capacity retention at 5°F35 models scored | 37% | Not ranked | 56% |
| HSPF268 models scored | 31% | Not ranked | 7.5 |
| SEER268 models scored | 26% | Not ranked | 14.3 |
| EER268 models scored | 36% | Not ranked | 10.6 |
| Heating capacity at 5°F35 models scored | 40% | Not ranked | 19,900 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 12.5% | 11 |
| CEE 2026 Tier 1 (Split ASHP) | 11.4% | 10 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 6.8% | 6 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 21.6% | 19 |
Sizes and duct types offered
- THERMAL ZONE (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 8 | 32% | 68% | 24% | 21% |
| Ducted, 2 tons | 9 | 42% | 73% | 36% | 28% |
| Ducted, 2.5–3 tons | 27 | 44% | 70% | 30% | 22% |
| Ducted, 3.5–4.5 tons | 31 | 46% | 64% | 35% | 30% |
| Ducted, 5 tons and up | 12 | 55% | 61% | 30% | 31% |
| Non-ducted, 2.5–3 tons | 1 | — | — | 5% | 5% |
Every THERMAL ZONE model in the market
- THERMAL ZONE models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top THERMAL ZONE models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1TZPLV362PATHERMAL ZONE · TZP Serieswith ducted air handler MAC-36HWDN1-MN0 | 3 tons35,000 Btu/h · Ducted | 82% | 2.00 | 10.0 | 32,000 | 15.2 | CEE 25CEE 26XcelES CC | 7 | 213885869 | Ducted, 2.5–3 tons | 78.6 |
| 2TZPLV482PATHERMAL ZONE · TZP Serieswith ducted air handler TZHVLE4821JA | 4 tons47,000 Btu/h · Ducted | 92% | 1.90 | 9.4 | 46,000 | 15.6 | XcelES CC | 4 | 211126512 | Ducted, 3.5–4.5 tons | 73.8 |
| 3TZPLV602PATHERMAL ZONE · TZP Serieswith ducted air handler TZHVLE6024JA | 4.5 tons55,000 Btu/h · Ducted | 82% | 1.91 | 9.4 | 48,500 | 15.3 | ES CC | 3 | 211126504 | Ducted, 3.5–4.5 tons | 71.3 |
| 4TZPLV302PATHERMAL ZONE · TZP Serieswith ducted air handler MAC-36HWDN1-MN0 | 2.5 tons30,000 Btu/h · Ducted | 82% | 1.85 | 9.7 | 27,000 | 15.5 | CEE 25CEE 26XcelES CC | 5 | 213885867 | Ducted, 2.5–3 tons | 67.8 |
| 5TZPLV182PATHERMAL ZONEwith ducted air handler H,RG21924+TD | 1.5 tons17,700 Btu/h · Ducted | 109% | 2.04 | 8.9 | 18,629 | 16.0 | CEE 25CEE 26XcelES CC | 4 | 214311494 | Ducted, up to 1.5 tons | 67.7 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1TZP15AZ60AJ2NTHERMAL ZONE · Serieswith ducted air handler TZHDLTST6024*NANAlso listed as TZPLAD1560AJN | 5 tons57,000 Btu/h · Ducted | 54% | 2.30 | 8.1 | 16.0 | 11.7 | CEE 25CEE 26ES CC | 2 | 211641701 | Ducted, 5 tons and up | 67.6 | 61.8 | 73.4 | Not a pick |
| 2TZPLV242PATHERMAL ZONE · TZP Serieswith ducted air handler TZHVLE2417JA | 2 tons24,000 Btu/h · Ducted | 94% | 1.91 | 10.0 | 17.4 | 11.7 | CEE 25CEE 26XcelES CC | 7 | 211126503 | Ducted, 2 tons | 65.8 | 66.5 | 65.1 | 66.5 |
| 3TZPLV182PATHERMAL ZONE · TZP Serieswith ducted air handler TZHVLE1817JA | 1.5 tons18,000 Btu/h · Ducted | 87% | 2.04 | 9.3 | 18.0 | 12.4 | CEE 25CEE 26XcelES CC | 4 | 211126509 | Ducted, up to 1.5 tons | 63.4 | 60.4 | 66.3 | 67.7 |
| 4TZPLAD1548AJNTHERMAL ZONE · Performancewith ducted air handler TZHDLVST4821*NAN | 4 tons45,500 Btu/h · Ducted | 60% | 2.50 | 8.1 | 15.2 | 11.7 | ES CC | 30 | 212508016 | Ducted, 3.5–4.5 tons | 62.1 | 60.9 | 63.2 | Not a pick |
| 5TZP15AZ42AJ2NTHERMAL ZONE · Valuewith indoor coil TCFZ4821STANM and furnace TZ80DZ2V100C5*A | 3.5 tons40,000 Btu/h · Ducted | 58% | 2.40 | 8.1 | 15.2 | 11.7 | ES CC | 4 | 212508047 | Ducted, 3.5–4.5 tons | 60.8 | 58.4 | 63.2 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | TZPLAD1560AJN | 2.50 | Ducted, 3.5–4.5 tons | 90% | 212506483 |
| Capacity retention at 5°F | TZPLV362PA | 102% | Ducted, 2.5–3 tons | 97% | 214311498 |
| HSPF2 | TZPLV362PA | 10.0 | Ducted, 2.5–3 tons | 93% | 213885869 |
| SEER2 | TZP15AZ60AJ2NAlso listed as TZPLAD1560AJN | 16.0 | Ducted, 5 tons and up | 70% | 211641701 |
| EER2 | TZP15AZ60AJ2NAlso listed as TZPLAD1560AJN | 11.7 | Ducted, 5 tons and up | 78% | 211641701 |
| Heating capacity at 5°F | TZPLV602PA | 48,500 Btu/h | Ducted, 3.5–4.5 tons | 95% | 211126504 |
THERMAL ZONE size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 67.7(50 is the typical model of its size class)TZPLV182PAwith ducted air handler H,RG21924+TD1 of 8 models qualify · AHRI 214311494 | 63.4(50 is the typical model of its size class)TZPLV182PAwith ducted air handler TZHVLE1817JA6 of 8 models have all five ratings · AHRI 211126509 |
| Ducted, 2 tons | 66.5(50 is the typical model of its size class)TZPLV242PAwith ducted air handler TZHVLE2417JA2 of 9 models qualify · AHRI 211126503 | 65.8(50 is the typical model of its size class)TZPLV242PAwith ducted air handler TZHVLE2417JA6 of 9 models have all five ratings · AHRI 211126503 |
| Ducted, 2.5–3 tons | 78.6(50 is the typical model of its size class)TZPLV362PAwith ducted air handler MAC-36HWDN1-MN02 of 27 models qualify · AHRI 213885869 | 58.0(50 is the typical model of its size class)TZPLAD1530AJNwith ducted air handler TZHDLVST3617*NAN10 of 27 models have all five ratings · AHRI 212508013 |
| Ducted, 3.5–4.5 tons | 73.8(50 is the typical model of its size class)TZPLV482PAwith ducted air handler TZHVLE4821JA2 of 31 models qualify · AHRI 211126512 | 62.1(50 is the typical model of its size class)TZPLAD1548AJNwith ducted air handler TZHDLVST4821*NAN10 of 30 models have all five ratings · AHRI 212508016 |
| Ducted, 5 tons and up | None on this board (0 of 12 models qualify) | 67.6(50 is the typical model of its size class)TZP15AZ60AJ2Nwith ducted air handler TZHDLTST6024*NANAlso listed as TZPLAD1560AJN3 of 13 models have all five ratings · AHRI 211641701 |
| Non-ducted, 2.5–3 tons | None on this board (0 of 1 models qualify) | None on this board (0 of 1 models have all five ratings) |
Newest THERMAL ZONE certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| TZPLAS1418AJNTHERMAL ZONEwith ducted air handler M2430C*1-BA*+M2430B**-EC | 1.5 tons15,000 Btu/h · Ducted | — | 57% | 6.8 | 12.0 | None | 5 | 216707367 |
| TZPLAD1548AJNTHERMAL ZONEwith ducted air handler V3642B-1EC*B | 3.5 tons40,000 Btu/h · Ducted | — | 59% | 7.2 | 12.0 | ES CC | 30 | 216707366 |
| TZPLAD1536AJNTHERMAL ZONEwith ducted air handler M3036C*1-BA*+M3036B**-EC | 2.5 tons30,000 Btu/h · Ducted | — | 67% | 6.8 | 12.0 | ES CC | 26 | 216707364 |
| TZPLAD1530AJNTHERMAL ZONEwith ducted air handler V2430B-1EC*B | 2 tons24,800 Btu/h · Ducted | — | 65% | 6.8 | 12.0 | CEE 25CEE 26ES CC | 27 | 216707363 |
| TZPLAD1524AJNTHERMAL ZONEwith ducted air handler M2430C*1-BA*+M2430B**-EC | 1.5 tons20,000 Btu/h · Ducted | — | 64% | 6.8 | 12.0 | CEE 25CEE 26ES CC | 23 | 216707360 |
Compare THERMAL ZONE