THERMAL ZONE heat pump efficiency: 101 outdoor models compared
THERMAL ZONE has 101 heat pump outdoor models certified with this refrigerant group, in 1,006 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes THERMAL ZONE makes. THERMAL ZONE has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 101
- AHRI certifications
- 1,006
- Efficiency index
- 30%
- Typical model vs same-size, same-type peers (60 models)
- Meet CEE 2025
- 7.9%
- 8 models
How THERMAL ZONE compares with comparable models
- THERMAL ZONE
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index60 models scored | 30% | Not ranked | — |
| COP at 5°F60 models scored | 40% | Not ranked | 1.86 |
| Capacity retention at 5°F60 models scored | 26% | Not ranked | 46% |
| HSPF2101 models scored | 23% | Not ranked | 7.2 |
| SEER2101 models scored | 24% | Not ranked | 14.3 |
| EER2101 models scored | 31% | Not ranked | 10.6 |
| Heating capacity at 5°F60 models scored | 29% | Not ranked | 18,550 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 7.9% | 8 |
| CEE 2026 Tier 1 (Split ASHP) | 5.9% | 6 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 7.9% | 8 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 7.9% | 8 |
Sizes and duct types offered
- THERMAL ZONE (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 5 | 34% | 80% | 19% | 33% |
| Ducted, 2 tons | 11 | 33% | 46% | 26% | 28% |
| Ducted, 2.5–3 tons | 30 | 26% | 40% | 19% | 20% |
| Ducted, 3.5–4.5 tons | 38 | 31% | 35% | 24% | 24% |
| Ducted, 5 tons and up | 17 | 28% | 16% | 26% | 27% |
Every THERMAL ZONE model in the market
- THERMAL ZONE models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top THERMAL ZONE models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1TZP15AY24AJ2NTHERMAL ZONEwith ducted air handler L(E,F)W30BJ | 2 tons21,800 Btu/h · Ducted | 102% | 2.88 | 7.8 | 21,400 | 15.2 | Xcel | 38 | 217200648 | Ducted, 2 tons | 75.5 |
| 2TZP15AY30AJ2NTHERMAL ZONEwith ducted air handler L(E,F)W30CJ | 2 tons26,200 Btu/h · Ducted | 102% | 2.67 | 7.8 | 27,000 | 15.2 | Xcel | 80 | 217200651 | Ducted, 2 tons | 74.1 |
| 3TZP15AY36AJ2NTHERMAL ZONEwith ducted air handler AEW37J+TDR | 2.5 tons31,600 Btu/h · Ducted | 102% | 2.66 | 7.5 | 31,800 | 14.5 | None | 76 | 217200653 | Ducted, 2.5–3 tons | 72.6 |
| 4TZP15AY18AJ2NTHERMAL ZONEwith ducted air handler PE(S,T)23J | 1.5 tons15,800 Btu/h · Ducted | 130% | 2.51 | 7.8 | 21,000 | 15.2 | XcelES CC | 30 | 217200657 | Ducted, up to 1.5 tons | 72.0 |
| 5TZID36H520ZCThermal Zonewith ducted air handler M36G34*+TXV+AMHE4D | 2 tons23,400 Btu/h · Ducted | 88% | 2.10 | 9.4 | 19,600 | 18.0 | CEE 25CEE 26XcelES CC | 3 | 218750016 | Ducted, 2 tons | 69.4 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1TZID36H520ZCThermal Zone · TZID36H520ZCwith ducted air handler TZID24H520ZA | 2 tons24,000 Btu/h · Ducted | 83% | 2.10 | 9.4 | 20.0 | 13.3 | CEE 25CEE 26XcelES CC | 3 | 217495954 | Ducted, 2 tons | 79.6 | 67.2 | 92.1 | 69.4 |
| 2TZID60H520ZCThermal Zone · TZID60H520ZCwith ducted air handler TZID48H520ZA | 4 tons47,500 Btu/h · Ducted | 71% | 2.10 | 9.0 | 17.5 | 11.3 | CEE 25CEE 26XcelES CC | 2 | 217589556 | Ducted, 3.5–4.5 tons | 64.4 | 63.9 | 64.9 | 64.7 |
| 3TZP15AY36AJ2NTHERMAL ZONEwith ducted air handler AEW37J+TDR | 2.5 tons31,600 Btu/h · Ducted | 102% | 2.66 | 7.5 | 14.5 | 11.7 | None | 76 | 217200653 | Ducted, 2.5–3 tons | 58.7 | 72.6 | 44.7 | 72.6 |
| 4TZP15AY18AJ2NTHERMAL ZONEwith ducted air handler L(E,F)W30BJ | 1.5 tons16,400 Btu/h · Ducted | 103% | 2.73 | 7.8 | 15.2 | 11.7 | XcelES CC | 30 | 217200644 | Ducted, up to 1.5 tons | 57.9 | 70.8 | 44.9 | 72.0 |
| 5TZP15AY24AJ2NTHERMAL ZONEwith ducted air handler L(E,F)W30BJ | 2 tons21,800 Btu/h · Ducted | 102% | 2.88 | 7.8 | 15.2 | 11.7 | Xcel | 38 | 217200648 | Ducted, 2 tons | 56.7 | 75.5 | 38.0 | 75.5 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | TZP15AY18AJ2N | 2.73 | Ducted, up to 1.5 tons | 99% | 217200644 |
| Capacity retention at 5°F | TZP15AY18AJ2N | 130% | Ducted, up to 1.5 tons | 100% | 217200657 |
| HSPF2 | TZID24H520ZCS | 9.7 | Ducted, 2 tons | 74% | 218043394 |
| SEER2 | TZID36H520ZC | 20.0 | Ducted, 2 tons | 87% | 217495954 |
| EER2 | TZID36H520ZC | 13.3 | Ducted, 2 tons | 93% | 217495954 |
| Heating capacity at 5°F | TZP15AY18AJ2N | 21,000 Btu/h | Ducted, up to 1.5 tons | 99% | 217200657 |
THERMAL ZONE size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 72.0(50 is the typical model of its size class)TZP15AY18AJ2Nwith ducted air handler PE(S,T)23J1 of 5 models qualify · AHRI 217200657 | 57.9(50 is the typical model of its size class)TZP15AY18AJ2Nwith ducted air handler L(E,F)W30BJ4 of 4 models have all five ratings · AHRI 217200644 |
| Ducted, 2 tons | 75.5(50 is the typical model of its size class)TZP15AY24AJ2Nwith ducted air handler L(E,F)W30BJ4 of 11 models qualify · AHRI 217200648 | 79.6(50 is the typical model of its size class)TZID36H520ZCwith ducted air handler TZID24H520ZA12 of 12 models have all five ratings · AHRI 217495954 |
| Ducted, 2.5–3 tons | 72.6(50 is the typical model of its size class)TZP15AY36AJ2Nwith ducted air handler AEW37J+TDR2 of 30 models qualify · AHRI 217200653 | 58.7(50 is the typical model of its size class)TZP15AY36AJ2Nwith ducted air handler AEW37J+TDR16 of 29 models have all five ratings · AHRI 217200653 |
| Ducted, 3.5–4.5 tons | 65.9(50 is the typical model of its size class)TZID48H520ZCSwith indoor coil TZID60H520ZACD and furnace MGV96U120D5C3 of 38 models qualify · AHRI 218782171 | 64.4(50 is the typical model of its size class)TZID60H520ZCwith ducted air handler TZID48H520ZA19 of 37 models have all five ratings · AHRI 217589556 |
| Ducted, 5 tons and up | None on this board (0 of 17 models qualify) | 56.6(50 is the typical model of its size class)TZP15AY60AJ2Nwith ducted air handler TZHDYTST6024*NAN9 of 19 models have all five ratings · AHRI 215415492 |
Newest THERMAL ZONE certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| TZP14AY48AJ2NTHERMAL ZONEwith ducted air handler AE*L+DM60A4J+TDR | 4 tons45,000 Btu/h · Ducted | 2.37 | 60% | 7.5 | 14.3 | None | 75 | 218827132 |
| TZP14AY42AJ2NTHERMAL ZONEwith ducted air handler AE*L+DM60A4J+TDR | 3 tons37,000 Btu/h · Ducted | 2.53 | 62% | 7.5 | 14.3 | None | 84 | 218827131 |
| TZP14AY36AJ2NTHERMAL ZONEwith ducted air handler AE*S+DM36A3J+TDR | 2.5 tons32,400 Btu/h · Ducted | 2.50 | 66% | 7.5 | 14.3 | None | 81 | 218827130 |
| TZP14AY30AJ2NTHERMAL ZONEwith ducted air handler AE*S+DM36A3J+TDR | 2 tons26,800 Btu/h · Ducted | 2.28 | 58% | 7.5 | 14.3 | None | 71 | 218827128 |
| TZP14AY24AJ2NTHERMAL ZONEwith ducted air handler AE*S+DM24A3J+TDR | 2 tons21,600 Btu/h · Ducted | 2.29 | 57% | 7.5 | 14.3 | None | 46 | 218827127 |
Compare THERMAL ZONE
THERMAL ZONE includes these brand names as listed in AHRI: THERMAL ZONE. Standards are checked against published thresholds; program rules beyond ratings are not checked.