TRUENORTH heat pump efficiency: 18 outdoor models compared

TRUENORTH has 18 heat pump outdoor models certified with this refrigerant group, in 32 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes TRUENORTH makes. TRUENORTH has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
18
AHRI certifications
32
Efficiency index
41%
Typical model vs same-size, same-type peers (24 models)
Meet CEE 2025
50%
9 models

How TRUENORTH compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
TRUENORTH against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of TRUENORTH’s own modelsTRUENORTH is strongest on heating capacity at 5°F (its typical model beats 56% of comparable models) and weakest on EER2 (33%).
  • TRUENORTH
  • Middle half of its models
  • Other ranked manufacturers
TRUENORTH

Source: AHRI Directory, NEEP · as of

Average peer percentile of TRUENORTH’s models
RatingBeats comparable modelsRankRaw median
Efficiency index24 models scored41%Not ranked—
COP at 5°F24 models scored36%Not ranked1.80
Capacity retention at 5°F24 models scored54%Not ranked71%
HSPF224 models scored45%Not ranked8.5
SEER224 models scored41%Not ranked17.5
EER224 models scored33%Not ranked10.3
Heating capacity at 5°F24 models scored56%Not ranked17,400 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
TRUENORTH’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • TRUENORTH (median, middle 50%, 10th–90th)
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsNon-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons230%25%29%33%
Ducted, 2 tons236%18%39%43%
Ducted, 2.5–3 tons741%36%41%44%
Ducted, 3.5–4.5 tons235%21%52%41%
Non-ducted, up to 1.5 tons633%40%37%26%
Non-ducted, 2 tons248%51%48%42%
Non-ducted, 2.5–3 tons368%49%82%65%

Every TRUENORTH model in the market

TRUENORTH’s 24 models with a known size and duct type, over the shape of the whole catalog.
TRUENORTH models by size and ratingColoured: TRUENORTH · grey shapes: all 11,475 models · lines: catalog medians by size
  • TRUENORTH models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 24 truenorth models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 11,475 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons1751.701.851.902.102.26
Ducted, 1 ton3401.851.902.002.402.65
Ducted, 1.5 tons7891.751.852.002.202.55
Ducted, 2 tons7821.731.802.002.102.33
Ducted, 2.5 tons7351.711.801.902.092.48
Ducted, 3 tons6521.681.701.902.062.36
Ducted, 3.5 tons6411.611.801.952.202.50
Ducted, 4 tons3671.701.801.912.022.52
Ducted, 4.5 tons5441.701.801.912.082.34
Ducted, 5 tons251.801.801.901.902.15
Non-ducted, 0.5 tons7171.751.811.972.102.19
Non-ducted, 1 ton1,0641.751.801.902.072.25
Non-ducted, 1.5 tons8861.801.801.872.072.21
Non-ducted, 2 tons5641.801.801.832.042.21
Non-ducted, 2.5 tons2751.801.811.841.862.03
Non-ducted, 3 tons5021.801.801.902.002.09
Non-ducted, 3.5 tons701.821.831.902.002.28
Non-ducted, 4 tons2631.801.801.982.002.10
Non-ducted, 4.5 tons1031.771.771.801.972.02
Non-ducted, 5 tons291.982.002.102.302.47

Source: AHRI Directory · as of

Top TRUENORTH models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 TRUENORTH cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1WLWHD(24)ND3MOTRUENORTH2 tons23,200 Btu/h · Non-ducted90%2.1010.021,60021.0CEE 25CEE 26Xcel3218593148Non-ducted, 2 tons76.1
2WLWHD(42)ND3MOTRUENORTH3 tons36,000 Btu/h · Non-ducted81%1.9210.032,40021.0CEE 25CEE 26Xcel3218593146Non-ducted, 2.5–3 tons73.7
3WLWHD(18)ND3MOTRUENORTH1.5 tons17,000 Btu/h · Non-ducted76%2.2110.013,60021.0CEE 25CEE 26Xcel3218593147Non-ducted, up to 1.5 tons73.1
4WLWHD(18)ND3POTRUENORTH1.5 tons18,000 Btu/h · Non-ducted72%2.2010.013,60021.0CEE 25CEE 26Xcel3218593161Non-ducted, up to 1.5 tons69.6
5WLWHD(36)ND3MOTRUENORTH3 tons34,000 Btu/h · Non-ducted90%1.8210.032,40021.0CEE 25CEE 26Xcel3218593145Non-ducted, 2.5–3 tons63.8

All-around best

Top 5 TRUENORTH models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1WLWHD(24)ND3MOTRUENORTH2 tons23,200 Btu/h · Non-ducted90%2.1010.021.012.5CEE 25CEE 26Xcel3218593148Non-ducted, 2 tons71.576.166.876.1
2WLWHD(42)ND3MOTRUENORTH3 tons36,000 Btu/h · Non-ducted81%1.9210.021.012.0CEE 25CEE 26Xcel3218593146Non-ducted, 2.5–3 tons70.273.766.773.7
3WLWHD(30)ND3MOTRUENORTH2.5 tons28,400 Btu/h · Non-ducted76%1.8410.021.012.5CEE 25CEE 26Xcel3218593149Non-ducted, 2.5–3 tons69.263.475.063.4
4WLWHD(36)ND3MOTRUENORTH3 tons34,000 Btu/h · Non-ducted90%1.8210.021.012.0CEE 25CEE 26Xcel3218593145Non-ducted, 2.5–3 tons65.363.866.763.8
5WLWHD(18)ND3MOTRUENORTH1.5 tons17,000 Btu/h · Non-ducted76%2.2110.021.012.0CEE 25CEE 26Xcel3218593147Non-ducted, up to 1.5 tons58.073.142.873.1

Best model on each rating

TRUENORTH’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FWLWHD(18)ND3MO2.21Non-ducted, up to 1.5 tons89%218593147
Capacity retention at 5°FWLWHD(30)ND3MO89%Ducted, 2.5–3 tons85%218593152
HSPF2WLWHD(36)ND3MO10.0Non-ducted, 2.5–3 tons82%218593145
SEER2WLWHD(24)ND3MO21.0Non-ducted, 2 tons66%218593148
EER2WLWHD(30)ND3MO12.5Non-ducted, 2.5–3 tons84%218593149
Heating capacity at 5°FWLWHD(18)ND3MO13,800 Btu/hNon-ducted, up to 1.5 tons84%218593155

All 18 TRUENORTH models in Explore

TRUENORTH size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
TRUENORTH: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons35.6(50 is the typical model of its size class)WLWHD(18)ND3MO2 of 2 models qualify · AHRI 21859315031.2(50 is the typical model of its size class)WLWHD(18)ND3MO2 of 2 models have all five ratings · AHRI 218593150
Ducted, 2 tons50.1(50 is the typical model of its size class)WLWHD(24)ND3MO1 of 2 models qualify · AHRI 21859315145.9(50 is the typical model of its size class)WLWHD(24)ND3MO2 of 2 models have all five ratings · AHRI 218593151
Ducted, 2.5–3 tons54.7(50 is the typical model of its size class)WLWHD(30)ND3MO5 of 7 models qualify · AHRI 21859315253.1(50 is the typical model of its size class)WLWHD(30)ND3MO6 of 6 models have all five ratings · AHRI 218593152
Ducted, 3.5–4.5 tons51.6(50 is the typical model of its size class)WLUD60W/A-D(U)with ducted air handler WLCAT60H/NAA1 of 2 models qualify · AHRI 21846182943.5(50 is the typical model of its size class)WLUD60W/A-D(U)with ducted air handler WLCAT60H/NAA3 of 3 models have all five ratings · AHRI 218461829
Non-ducted, up to 1.5 tons73.1(50 is the typical model of its size class)WLWHD(18)ND3MO5 of 6 models qualify · AHRI 21859314758.0(50 is the typical model of its size class)WLWHD(18)ND3MO6 of 6 models have all five ratings · AHRI 218593147
Non-ducted, 2 tons76.1(50 is the typical model of its size class)WLWHD(24)ND3MO1 of 2 models qualify · AHRI 21859314871.5(50 is the typical model of its size class)WLWHD(24)ND3MO2 of 2 models have all five ratings · AHRI 218593148
Non-ducted, 2.5–3 tons73.7(50 is the typical model of its size class)WLWHD(42)ND3MO3 of 3 models qualify · AHRI 21859314670.2(50 is the typical model of its size class)WLWHD(42)ND3MO3 of 3 models have all five ratings · AHRI 218593146

All-around board, every manufacturer

Newest TRUENORTH certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified TRUENORTH outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
WLW24HQ19SDOTRUENORTHwith ductless indoor unit WLW24HQ19SDI2 tons22,000 Btu/h · Non-ducted1.8063%8.518.0CEE 25CEE 261218694233
WLWHD(18)ND3POTRUENORTH1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9271%9.021.0CEE 25CEE 26Xcel3218593162
WLWHD(42)ND3MOTRUENORTH3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8081%9.018.5CEE 25CEE 26Xcel3218593159
WLWHD(36)ND3MOTRUENORTH3 tons34,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8083%9.018.5CEE 25CEE 26Xcel3218593158
WLWHD(30)ND3MOTRUENORTH2.5 tons28,400 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.8083%9.018.5CEE 25CEE 26Xcel3218593157

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for TRUENORTH in this group.

Compare TRUENORTH

Manufacturers of a similar size, side by side.

TRUENORTH includes these brand names as listed in AHRI: TRUENORTH. Standards are checked against published thresholds; program rules beyond ratings are not checked.