TRUENORTH heat pump efficiency: 19 outdoor models compared
TRUENORTH has 19 heat pump outdoor models certified with this refrigerant group, in 71 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes TRUENORTH makes. TRUENORTH has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 19
- AHRI certifications
- 71
- Efficiency index
- 42%
- Typical model vs same-size, same-type peers (25 models)
- Meet CEE 2025
- 57.9%
- 11 models
How TRUENORTH compares with comparable models
- TRUENORTH
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index25 models scored | 42% | Not ranked | — |
| COP at 5°F25 models scored | 37% | Not ranked | 1.80 |
| Capacity retention at 5°F25 models scored | 59% | Not ranked | 72% |
| HSPF225 models scored | 47% | Not ranked | 8.5 |
| SEER225 models scored | 39% | Not ranked | 17.5 |
| EER225 models scored | 33% | Not ranked | 10.5 |
| Heating capacity at 5°F25 models scored | 61% | Not ranked | 20,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 57.9% | 11 |
| CEE 2026 Tier 1 (Split ASHP) | 52.6% | 10 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 68.4% | 13 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 57.9% | 11 |
Sizes and duct types offered
- TRUENORTH (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 3 | 29% | 21% | 30% | 31% |
| Ducted, 2 tons | 3 | 40% | 20% | 53% | 37% |
| Ducted, 2.5 to 3 tons | 5 | 45% | 42% | 43% | 45% |
| Ducted, 3.5 to 4.5 tons | 3 | 35% | 28% | 46% | 38% |
| Non-ducted, up to 1.5 tons | 6 | 34% | 43% | 37% | 26% |
| Non-ducted, 2 tons | 2 | 49% | 54% | 48% | 43% |
| Non-ducted, 2.5 to 3 tons | 3 | 69% | 51% | 82% | 66% |
Every TRUENORTH model in the market
- TRUENORTH models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 179 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 354 | 1.85 | 1.89 | 2.00 | 2.40 | 2.63 |
| Ducted, 1.5 tons | 802 | 1.75 | 1.85 | 2.00 | 2.20 | 2.52 |
| Ducted, 2 tons | 791 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 758 | 1.70 | 1.80 | 1.90 | 2.10 | 2.44 |
| Ducted, 3 tons | 674 | 1.68 | 1.73 | 1.90 | 2.06 | 2.34 |
| Ducted, 3.5 tons | 662 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 373 | 1.70 | 1.80 | 1.91 | 2.02 | 2.50 |
| Ducted, 4.5 tons | 575 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 29 | 1.80 | 1.80 | 1.86 | 1.90 | 2.10 |
| Non-ducted, 0.5 tons | 774 | 1.75 | 1.80 | 1.94 | 2.09 | 2.19 |
| Non-ducted, 1 ton | 1,135 | 1.75 | 1.80 | 1.89 | 2.07 | 2.24 |
| Non-ducted, 1.5 tons | 946 | 1.75 | 1.80 | 1.87 | 2.07 | 2.20 |
| Non-ducted, 2 tons | 598 | 1.78 | 1.80 | 1.83 | 2.00 | 2.21 |
| Non-ducted, 2.5 tons | 327 | 1.75 | 1.80 | 1.84 | 1.86 | 2.02 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.80 | 1.90 | 2.00 | 2.07 |
| Non-ducted, 3.5 tons | 71 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 269 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 106 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 31 | 1.89 | 2.00 | 2.07 | 2.30 | 2.40 |
Source: AHRI Directory · as of
TRUENORTH in the cold
- All listed models (median, middle 50% and 80%)
- TRUENORTH (median, middle 50%)
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 3,710 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 3,710 | 65% | 68% | 76% | 83% | 92% |
| All rated models, 5°F | 3,710 | 55% | 58% | 66% | 75% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 3,710 | 2.64 | 2.87 | 3.1 | 3.32 | 3.53 |
| All rated models, 17°F | 3,710 | 1.98 | 2.05 | 2.2 | 2.34 | 2.49 |
| All rated models, 5°F | 3,710 | 1.8 | 1.83 | 1.92 | 2.03 | 2.21 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| TRUENORTH, 47°F | 17 | 100% | 100% | 100% | 100% | 100% |
| TRUENORTH, 17°F | 17 | 67% | 73% | 84% | 88% | 91% |
| TRUENORTH, 5°F | 17 | 57% | 61% | 71% | 75% | 77% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| TRUENORTH, 47°F | 17 | 2.94 | 2.99 | 3.17 | 3.27 | 3.32 |
| TRUENORTH, 17°F | 17 | 2 | 2.08 | 2.3 | 2.41 | 2.46 |
| TRUENORTH, 5°F | 17 | 1.77 | 1.8 | 1.8 | 1.84 | 2.14 |
Source: NEEP ccASHP list · as of
Top TRUENORTH models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1WLWHD(24)ND3MOTRUENORTH · M-Series | 2 tons23,200 Btu/h · Non-ducted | 90% | 2.10 | 10.0 | 21,600 | 21.0 | CEE 25CEE 26XcelES CC | 3 | 218593148 | Non-ducted, 2 tons | 77.3 |
| 2WLWHD(42)ND3MOTRUENORTH · M-Series | 3 tons36,000 Btu/h · Non-ducted | 81% | 1.92 | 10.0 | 32,400 | 21.0 | CEE 25CEE 26XcelES CC | 3 | 218593146 | Non-ducted, 2.5 to 3 tons | 74.7 |
| 3WLWHD(18)ND3MOTRUENORTH · M-Series | 1.5 tons17,000 Btu/h · Non-ducted | 76% | 2.21 | 10.0 | 13,600 | 21.0 | CEE 25CEE 26XcelES CC | 3 | 218593147 | Non-ducted, up to 1.5 tons | 74.0 |
| 4WLWHD(18)ND3POTRUENORTH · M-Series | 1.5 tons18,000 Btu/h · Non-ducted | 72% | 2.20 | 10.0 | 13,600 | 21.0 | CEE 25CEE 26XcelES CC | 3 | 218593161 | Non-ducted, up to 1.5 tons | 70.6 |
| 5WLWHD(36)ND3MOTRUENORTH · M-Series | 3 tons34,000 Btu/h · Non-ducted | 90% | 1.82 | 10.0 | 32,400 | 21.0 | CEE 25CEE 26XcelES CC | 3 | 218593145 | Non-ducted, 2.5 to 3 tons | 65.5 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1WLWHD(24)ND3MOTRUENORTH · M-Series | 2 tons23,200 Btu/h · Non-ducted | 90% | 2.10 | 10.0 | 21.0 | 12.5 | CEE 25CEE 26XcelES CC | 3 | 218593148 | Non-ducted, 2 tons | 72.2 | 77.3 | 67.1 | 77.3 |
| 2WLWHD(42)ND3MOTRUENORTH · M-Series | 3 tons36,000 Btu/h · Non-ducted | 81% | 1.92 | 10.0 | 21.0 | 12.0 | CEE 25CEE 26XcelES CC | 3 | 218593146 | Non-ducted, 2.5 to 3 tons | 70.9 | 74.7 | 67.1 | 74.7 |
| 3WLWHD(30)ND3MOTRUENORTH · M-Series | 2.5 tons28,400 Btu/h · Non-ducted | 76% | 1.84 | 10.0 | 21.0 | 12.5 | CEE 25CEE 26XcelES CC | 3 | 218593149 | Non-ducted, 2.5 to 3 tons | 70.2 | 65.0 | 75.4 | 65.0 |
| 4WLWHD(36)ND3MOTRUENORTH · M-Series | 3 tons34,000 Btu/h · Non-ducted | 90% | 1.82 | 10.0 | 21.0 | 12.0 | CEE 25CEE 26XcelES CC | 3 | 218593145 | Non-ducted, 2.5 to 3 tons | 66.3 | 65.5 | 67.1 | 65.5 |
| 5WLUD60W/A-D(U)TRUENORTH · FLEXX High-efficiency Serieswith ducted air handler WLUD48AH2/A-D(U) | 4 tons48,000 Btu/h · Ducted | 81% | 1.80 | 9.0 | 17.0 | 11.0 | CEE 25CEE 26XcelES CC | 5 | 218828999 | Ducted, 3.5 to 4.5 tons | 63.3 | 58.2 | 68.3 | 58.2 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | WLWHD(18)ND3MO | 2.21 | Non-ducted, up to 1.5 tons | 89% | 218593147 |
| Capacity retention at 5°F | WLWHD(30)ND3MO | 89% | Ducted, 2.5 to 3 tons | 86% | 218593152 |
| HSPF2 | WLWHD(36)ND3MO | 10.0 | Non-ducted, 2.5 to 3 tons | 82% | 218593145 |
| SEER2 | WLUD60W/A-D(U) | 17.0 | Ducted, 3.5 to 4.5 tons | 77% | 218828999 |
| EER2 | WLWHD(30)ND3MO | 12.5 | Non-ducted, 2.5 to 3 tons | 84% | 218593149 |
| Heating capacity at 5°F | WLWHD(18)ND3MO | 13,800 Btu/h | Non-ducted, up to 1.5 tons | 85% | 218593155 |
TRUENORTH size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 36.3(50 is the typical model of its size class)WLWHD(18)ND3MO3 of 3 models qualify · AHRI 218593150 | 31.8(50 is the typical model of its size class)WLWHD(18)ND3MO3 of 3 models have all five ratings · AHRI 218593150 |
| Ducted, 2 tons | 50.3(50 is the typical model of its size class)WLWHD(24)ND3MO4 of 4 models qualify · AHRI 218593151 | 60.8(50 is the typical model of its size class)WLUD36W/A-D(U)with ducted air handler WLUD24AH2/A-D(U)5 of 5 models have all five ratings · AHRI 218828996 |
| Ducted, 2.5 to 3 tons | 55.4(50 is the typical model of its size class)WLUD36W/A-D(U)with ducted air handler WLUD36AH2/A-D(U)4 of 4 models qualify · AHRI 218828997 | 53.0(50 is the typical model of its size class)WLWHD(30)ND3MO3 of 3 models have all five ratings · AHRI 218593152 |
| Ducted, 3.5 to 4.5 tons | 58.2(50 is the typical model of its size class)WLUD60W/A-D(U)with ducted air handler WLUD48AH2/A-D(U)1 of 3 models qualify · AHRI 218828999 | 63.3(50 is the typical model of its size class)WLUD60W/A-D(U)with ducted air handler WLUD48AH2/A-D(U)3 of 3 models have all five ratings · AHRI 218828999 |
| Non-ducted, up to 1.5 tons | 74.0(50 is the typical model of its size class)WLWHD(18)ND3MO5 of 6 models qualify · AHRI 218593147 | 58.6(50 is the typical model of its size class)WLWHD(18)ND3MO6 of 6 models have all five ratings · AHRI 218593147 |
| Non-ducted, 2 tons | 77.3(50 is the typical model of its size class)WLWHD(24)ND3MO1 of 2 models qualify · AHRI 218593148 | 72.2(50 is the typical model of its size class)WLWHD(24)ND3MO1 of 2 models have all five ratings · AHRI 218593148 |
| Non-ducted, 2.5 to 3 tons | 74.7(50 is the typical model of its size class)WLWHD(42)ND3MO3 of 3 models qualify · AHRI 218593146 | 70.9(50 is the typical model of its size class)WLWHD(42)ND3MO3 of 3 models have all five ratings · AHRI 218593146 |
Newest TRUENORTH certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| WLUD60W2/D-D(U)TRUENORTHwith ducted air handler WLCAT48H/NAA | 4 tons46,500 Btu/h · Ducted | 1.90 | 64% | 7.5 | 14.5 | None | 3 | 218861268 |
| WLUD60W/A-D(U)TRUENORTHwith ducted air handler WLCAT48H/NAA | 4 tons47,000 Btu/h · Ducted | 1.80 | 70% | 8.5 | 15.2 | CEE 25CEE 26XcelES CC | 5 | 218861267 |
| WLUD36W/A-D(U)TRUENORTHwith indoor coil WLCAT24*/NAA and furnace WPV035T2AA | 2 tons22,000 Btu/h · Ducted | 1.80 | 80% | 8.5 | 15.2 | CEE 25CEE 26XcelES CC | 31 | 218854121 |
| WLUD36W2/D-D(U)TRUENORTHwith ducted air handler WLCAT24F/NAA | 2 tons23,000 Btu/h · Ducted | 1.80 | 85% | 8.5 | 15.2 | Xcel | 3 | 218829004 |
| WLUD42W2/D-D(U)TRUENORTHwith ducted air handler WLCAT24F/NAA | 2 tons23,000 Btu/h · Ducted | 1.80 | 81% | 8.5 | 15.2 | Xcel | 3 | 218829003 |