Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
TRUST AIR CONDITIONERS heat pump efficiency: 42 outdoor models compared
TRUST AIR CONDITIONERS has 42 heat pump outdoor models certified with this refrigerant group, in 103 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes TRUST AIR CONDITIONERS makes. TRUST AIR CONDITIONERS has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 42
- AHRI certifications
- 103
- Efficiency index
- 59%
- Typical model vs same-size, same-type peers (63 models)
- Meet CEE 2025
- 69%
- 29 models
How TRUST AIR CONDITIONERS compares with comparable models
- TRUST AIR CONDITIONERS
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index63 models scored | 59% | Not ranked | — |
| COP at 5°F63 models scored | 52% | Not ranked | 1.98 |
| Capacity retention at 5°F63 models scored | 57% | Not ranked | 70% |
| HSPF263 models scored | 72% | Not ranked | 9.5 |
| SEER263 models scored | 65% | Not ranked | 19.8 |
| EER263 models scored | 50% | Not ranked | 11.4 |
| Heating capacity at 5°F63 models scored | 57% | Not ranked | 20,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 69% | 29 |
| CEE 2026 Tier 1 (Split ASHP) | 66.7% | 28 |
| CEE Advanced Tier (Split ASHP) | 2.4% | 1 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 52.4% | 22 |
| DOE Cold Climate Heat Pump Challenge | 2.4% | 1 |
| ENERGY STAR Cold Climate | 57.1% | 24 |
Sizes and duct types offered
- TRUST AIR CONDITIONERS (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 10 | 62% | 52% | 71% | 69% |
| Ducted, 2 tons | 4 | 65% | 60% | 88% | 68% |
| Ducted, 2.5–3 tons | 10 | 57% | 43% | 81% | 66% |
| Ducted, 3.5–4.5 tons | 8 | 57% | 45% | 87% | 65% |
| Ducted, 5 tons and up | 1 | 42% | 41% | 85% | 35% |
| Non-ducted, up to 1.5 tons | 14 | 59% | 60% | 65% | 63% |
| Non-ducted, 2 tons | 3 | 61% | 73% | 73% | 61% |
| Non-ducted, 2.5–3 tons | 8 | 60% | 55% | 60% | 66% |
| Non-ducted, 3.5–4.5 tons | 5 | 54% | 43% | 57% | 60% |
Every TRUST AIR CONDITIONERS model in the market
- TRUST AIR CONDITIONERS models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top TRUST AIR CONDITIONERS models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1OUS09H/O4S4PTRUST AIR CONDITIONERS · O-serieswith ductless indoor unit IUMW106H/I41P | 0.5 tons6,000 Btu/h · Non-ducted | 107% | 2.09 | 13.6 | 7,500 | 26.5 | CEE 25CEE 26XcelES CC | 4 | 208816913 | Non-ducted, up to 1.5 tons | 89.3 |
| 2OAH48H/O4S41PTRUST AIR CONDITIONERS · O-serieswith ducted air handler IUMDL48H/I43P | 4 tons48,000 Btu/h · Ducted | 88% | 2.02 | 10.3 | 46,000 | 14.3 | None | 3 | 208280127 | Ducted, 3.5–4.5 tons | 86.4 |
| 3OAH24H/O4S4PTRUST AIR CONDITIONERS · O-serieswith ductless indoor unit IUMC424H/I41P | 2 tons24,000 Btu/h · Non-ducted | 103% | 2.00 | 11.5 | 25,800 | 20.5 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 208816925 | Non-ducted, 2 tons | 86.1 |
| 4OUS24H/O4S4PTRUST AIR CONDITIONERS · O-serieswith ducted air handler IUMDL24H/I43P | 2 tons23,000 Btu/h · Ducted | 80% | 2.30 | 11.2 | 20,000 | 19.0 | CEE 25CEE 26XcelES CC | 4 | 208816929 | Ducted, 2 tons | 80.3 |
| 5OAH36H/O4S41PTRUST AIR CONDITIONERS · O-serieswith ducted air handler IUMDL36H/I43P | 3 tons36,000 Btu/h · Ducted | 86% | 1.98 | 11.0 | 36,000 | 16.5 | ES CC | 3 | 208280125 | Ducted, 2.5–3 tons | 79.9 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1OUS09H/O4S4PTRUST AIR CONDITIONERS · O-serieswith ductless indoor unit IUMW106H/I41P | 0.5 tons6,000 Btu/h · Non-ducted | 107% | 2.09 | 13.6 | 26.5 | 15.8 | CEE 25CEE 26XcelES CC | 4 | 208816913 | Non-ducted, up to 1.5 tons | 92.0 | 89.3 | 94.6 | 89.3 |
| 2OAH09H/O4S4PTRUST AIR CONDITIONERS · O-serieswith ductless indoor unit IUMW109H/I41P | 1 ton9,000 Btu/h · Non-ducted | 88% | 1.97 | 11.5 | 28.1 | 16.2 | CEE 25CEE 26XcelES CC | 3 | 208816914 | Non-ducted, up to 1.5 tons | 87.0 | 76.2 | 97.9 | 76.2 |
| 3OAH09H/O4S4PTRUST AIR CONDITIONERS · O-serieswith ducted air handler IUMDL09H/I43P | 1 ton9,000 Btu/h · Ducted | 108% | 1.90 | 12.0 | 20.2 | 13.2 | CEE 25CEE 26XcelES CC | 3 | 208816930 | Ducted, up to 1.5 tons | 85.2 | 74.9 | 95.5 | 74.9 |
| 4OAH24H/O4S4PTRUST AIR CONDITIONERS · O-serieswith ductless indoor unit IUMW124H/I41P | 2 tons24,000 Btu/h · Non-ducted | 86% | 2.21 | 11.4 | 21.5 | 13.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 4 | 208816917 | Non-ducted, 2 tons | 84.3 | 84.5 | 84.1 | 86.1 |
| 5OUS24H/O4S4PTRUST AIR CONDITIONERS · O-serieswith ducted air handler IUMDL24H/I43P | 2 tons23,000 Btu/h · Ducted | 80% | 2.30 | 11.2 | 19.0 | 12.5 | CEE 25CEE 26XcelES CC | 4 | 208816929 | Ducted, 2 tons | 83.8 | 80.3 | 87.4 | 80.3 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | OUS12H/O4S4P | 2.39 | Non-ducted, up to 1.5 tons | 97% | 208816910 |
| Capacity retention at 5°F | OAH36H/O4S41P | 103% | Non-ducted, 2.5–3 tons | 95% | 208280093 |
| HSPF2 | OAH48H/O4S41P | 10.3 | Ducted, 3.5–4.5 tons | 99% | 208280127 |
| SEER2 | M3S27H/O4S4P | 24.6 | Non-ducted, 2.5–3 tons | 99% | 208284476 |
| EER2 | OAH09H/O4S4P | 16.2 | Non-ducted, up to 1.5 tons | 98% | 208816914 |
| Heating capacity at 5°F | OAH36H/O4S41P | 41,000 Btu/h | Non-ducted, 2.5–3 tons | 98% | 208280093 |
TRUST AIR CONDITIONERS size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 74.9(50 is the typical model of its size class)OAH09H/O4S4Pwith ducted air handler IUMDL09H/I43P8 of 10 models qualify · AHRI 208816930 | 85.2(50 is the typical model of its size class)OAH09H/O4S4Pwith ducted air handler IUMDL09H/I43P10 of 10 models have all five ratings · AHRI 208816930 |
| Ducted, 2 tons | 80.3(50 is the typical model of its size class)OUS24H/O4S4Pwith ducted air handler IUMDL24H/I43P4 of 4 models qualify · AHRI 208816929 | 83.8(50 is the typical model of its size class)OUS24H/O4S4Pwith ducted air handler IUMDL24H/I43P4 of 4 models have all five ratings · AHRI 208816929 |
| Ducted, 2.5–3 tons | 79.9(50 is the typical model of its size class)OAH36H/O4S41Pwith ducted air handler IUMDL36H/I43P5 of 10 models qualify · AHRI 208280125 | 75.4(50 is the typical model of its size class)M3S27H/O4S4P10 of 10 models have all five ratings · AHRI 208284477 |
| Ducted, 3.5–4.5 tons | 86.4(50 is the typical model of its size class)OAH48H/O4S41Pwith ducted air handler IUMDL48H/I43P5 of 8 models qualify · AHRI 208280127 | 82.0(50 is the typical model of its size class)M5H48H/O4S4P8 of 8 models have all five ratings · AHRI 208284495 |
| Ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 41.7(50 is the typical model of its size class)AH60H/O44Pwith ducted air handler AH60H/I44P1 of 1 models have all five ratings · AHRI 208284013 |
| Non-ducted, up to 1.5 tons | 89.3(50 is the typical model of its size class)OUS09H/O4S4Pwith ductless indoor unit IUMW106H/I41P8 of 14 models qualify · AHRI 208816913 | 92.0(50 is the typical model of its size class)OUS09H/O4S4Pwith ductless indoor unit IUMW106H/I41P14 of 14 models have all five ratings · AHRI 208816913 |
| Non-ducted, 2 tons | 86.1(50 is the typical model of its size class)OAH24H/O4S4Pwith ductless indoor unit IUMC424H/I41P2 of 3 models qualify · AHRI 208816925 | 84.3(50 is the typical model of its size class)OAH24H/O4S4Pwith ductless indoor unit IUMW124H/I41P3 of 3 models have all five ratings · AHRI 208816917 |
| Non-ducted, 2.5–3 tons | 79.3(50 is the typical model of its size class)M4H36H/O4S4P3 of 8 models qualify · AHRI 208284491 | 82.8(50 is the typical model of its size class)M4H36H/O4S4P8 of 8 models have all five ratings · AHRI 208284491 |
| Non-ducted, 3.5–4.5 tons | 76.2(50 is the typical model of its size class)M5H48H/O4S4P4 of 5 models qualify · AHRI 208284494 | 77.9(50 is the typical model of its size class)M5H48H/O4S4P5 of 5 models have all five ratings · AHRI 208284494 |
Newest TRUST AIR CONDITIONERS certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| AA60H/O44PTRUST AIR CONDITIONERS · Arcticwith ducted air handler AH60H/I44P | 4.5 tons55,000 Btu/h · Ducted | 1.91 | 82% | 9.4 | 15.3 | ES CC | 2 | 216778966 |
| AA30H/O44PTRUST AIR CONDITIONERS · Arcticwith ducted air handler CX36M/W4T4 | 2.5 tons30,000 Btu/h · Ducted | 1.85 | 82% | 9.7 | 15.5 | CEE 25CEE 26XcelES CC | 2 | 216778965 |
| AA24H/O44PTRUST AIR CONDITIONERS · Arcticwith ducted air handler CX24M/W4T3 | 2 tons24,000 Btu/h · Ducted | 1.95 | 80% | 9.5 | 16.5 | CEE 25CEE 26XcelES CC | 2 | 216778964 |
| AA18H/O44PTRUST AIR CONDITIONERS · Arcticwith ducted air handler CX24M/W4T3 | 1.5 tons18,000 Btu/h · Ducted | 2.20 | 79% | 9.5 | 16.1 | CEE 25CEE 26XcelES CC | 2 | 216778963 |
| AH30H/O44PTRUST AIR CONDITIONERS · Infinitywith ducted air handler CX36M/W4T4 | 2.5 tons30,000 Btu/h · Ducted | 1.81 | 61% | 9.3 | 14.9 | None | 2 | 216778962 |
Compare TRUST AIR CONDITIONERS
TRUST AIR CONDITIONERS includes these brand names as listed in AHRI: TRUST AIR CONDITIONERS. Standards are checked against published thresholds; program rules beyond ratings are not checked.