Skip to content

York heat pumps: how do their ratings compare?

A typical York heat pump beats 51% of similar heat pumps (same size and type), which is about average. York has 181 heat pump models in this list, also sold as Champion, Champion Heating and Cooling, Coleman, Evcon, Fraser-Johnston and 5 more names.

Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated

Overall score

51%

of similar heat pumps beaten by its typical model

About average

Ranked 18 among brands with a QMID on file. Based on 138 models with every rating.

York, rating by ratingStrongest on efficiency on a 5°f day (beats 69%), weakest on winter-long heating efficiency (beats 37%).
  • Efficiency on a 5°F dayCOP at 5°FBeats 69%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FBeats 50%
  • Winter-long heating efficiencyHSPF2Beats 37%
  • Summer-long cooling efficiencySEER2Beats 38%
  • Hot-day cooling efficiencyEER2Beats 57%

Average (50%)

Each bar: the share of similar heat pumps a typical model beats on that rating.

Rebate standards

Share of this brand’s models that meet the efficiency levels rebate programs use. Programs can have other rules too.
  • 27%

    meet CEE 2025 Tier 1, the level many utility rebates use.

    48 models. All brands: 49%.

    See them

  • 26%

    meet Xcel Energy Colorado’s cold-climate rebate levels.

    47 models. All brands: 38%.

    See them

  • 1%

    reach the cold-climate tier: full heating output and a COP of 2.1 or more at 5°F.

    1 model. All brands: 1%.

    See them

York all-around best, by size

Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?

34 of York’s 51 models of this size and type have all five ratings.

  1. 1YMSJYH048BAAND-1with ducted air handler YMSJXH048BAAN--5York3 tons · 34,200 Btu/h · DuctedNot a cold-climate pick: keeps 61% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    62% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    2.02 (COP at 5°F)
    Good
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    12.0 (EER2)
    Great
    76.1score / 100Heating 66 · Cooling 86
  2. 2YZT36B21with ducted air handler AE(D,N,U)+CM48E44+TDRYork2.5 tons · 32,600 Btu/h · DuctedNot a cold-climate pick: keeps 68% of its heat at 5°FMeets CEE 2025, CEE 2026
    Heat kept at 5°F
    68% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.78 (COP at 5°F)
    Top 10%
    Winter efficiency
    7.8 (HSPF2)
    Below the middle
    Cooling efficiency
    18.2 (SEER2)
    Great
    Hot-day cooling
    13.0 (EER2)
    Top 10%
    75.7score / 100Heating 62 · Cooling 89
  3. 3YZV36B21with ducted air handler JHVVB36DE2C2N1+CCYork2.5 tons · 32,000 Btu/h · DuctedCold-climate pick, score 65.4Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    79% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Good
    Winter efficiency
    8.5 (HSPF2)
    Good
    Cooling efficiency
    19.5 (SEER2)
    Great
    Hot-day cooling
    12.4 (EER2)
    Top 10%
    74.5score / 100Heating 58 · Cooling 91
  4. 4YVAHP036B21S*YorkAlso sold as Coleman CVAHP036B21S3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 58.3Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    79% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.77 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    18.5 (SEER2)
    Great
    Hot-day cooling
    13.2 (EER2)
    Top 10%
    74.3score / 100Heating 58 · Cooling 90
  5. 5THF2B36T21with ducted air handler AE(D,N,U)+CM48C34+TDRYork (sold as Luxaire)3 tons · 34,200 Btu/h · DuctedCold-climate pick, score 69.5Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    74% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    3.16 (COP at 5°F)
    Top 10%
    Winter efficiency
    8.1 (HSPF2)
    Below the middle
    Cooling efficiency
    15.5 (SEER2)
    Below the middle
    Hot-day cooling
    12.1 (EER2)
    Top 10%
    69.3score / 100Heating 70 · Cooling 69

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

What to do next

Advanced view: York’s rank on each rating, its models inside every size and type, cold-weather curves, newest certifications.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter