Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
AIRDACH vs Della heat pumps
Measured against models of the same size and duct type, AIRDACH scores higher on 6 of the 6 ratings. AIRDACH has 23 outdoor models, Della has 22 outdoor models. AIRDACH has no QMID on file and is not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- AIRDACH
- Della
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | AIRDACH | Della |
|---|---|---|
| Efficiency index | 57% (higher)median — | 39% (higher)median — · 27th ranked |
| COP at 5°F | 47% (higher)median 1.91 | 42% (higher)median 1.80 · 25th ranked |
| Capacity retention at 5°F | 39% (higher)median 67% | 37% (higher)median 70% · 26th ranked |
| HSPF2 | 49% (higher)median 8.1 | 23% (higher)median 8.5 · 27th ranked |
| SEER2 | 54% (higher)median 16.0 | 35% (higher)median 19.0 · 27th ranked |
| EER2 | 58% (higher)median 11.7 | 28% (higher)median 10.0 · 27th ranked |
| Heating capacity at 5°F | 41% (higher)median 14,000 Btu/h | 37% (higher)median 11,600 Btu/h · 26th ranked |
| Outdoor models | 23 | 22 |
| AHRI certifications | 34 | 22 |
Share of models meeting each standard
| Standard | AIRDACH | Della |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 39.1%9 models | 54.5%12 models |
| CEE 2026 Tier 1 (Split ASHP) | 39.1%9 models | 45.5%10 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 21.7%5 models | 36.4%8 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 18.2%4 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- AIRDACH
- Della
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | AIRDACH | Della |
|---|---|---|
| Ducted, up to 1.5 tons | 2 · index 57% | None |
| Ducted, 2 tons | 2 · index — | None |
| Ducted, 2.5–3 tons | 5 · index 66% | None |
| Ducted, 3.5–4.5 tons | 6 · index 64% | None |
| Non-ducted, up to 1.5 tons | 6 · index 58% | 16 · index 43% |
| Non-ducted, 2 tons | 1 · index 56% | 3 · index 39% |
| Non-ducted, 2.5–3 tons | 4 · index 50% | 3 · index 27% |
| Non-ducted, 3.5–4.5 tons | 1 · index 52% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | AIRDACHCold-climate score, best model | DellaCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 46.5(50 is the typical model of its size class)AMSH1800VM1-D1 of 2 models qualify · AHRI 210474672 | No models in this size class |
| Ducted, 2 tons | None on this board (0 of 2 models qualify) | No models in this size class |
| Ducted, 2.5–3 tons | None on this board (0 of 5 models qualify) | No models in this size class |
| Ducted, 3.5–4.5 tons | None on this board (0 of 6 models qualify) | No models in this size class |
| Non-ducted, up to 1.5 tons | 70.6(50 is the typical model of its size class) (higher)ACSH1823VM2-Dwith ductless indoor unit AIWH1800VM2-D3 of 6 models qualify · AHRI 209948207 | 68.8(50 is the typical model of its size class)048-TP-12K2V-23S-OUTwith ductless indoor unit 048-TP-12K2V-23S-IN8 of 16 models qualify · AHRI 213927343 |
| Non-ducted, 2 tons | None on this board (0 of 1 models qualify) | None on this board (0 of 3 models qualify) |
| Non-ducted, 2.5–3 tons | 50.1(50 is the typical model of its size class)AMSH2700VM1-D1 of 4 models qualify · AHRI 210474674 | None on this board (0 of 3 models qualify) |
| Non-ducted, 3.5–4.5 tons | 39.4(50 is the typical model of its size class)AMSH4800VM1-D1 of 1 models qualify · AHRI 210474680 | No models in this size class |
All-around best
| Size and duct type | AIRDACHAll-around score, best model | DellaAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 56.7(50 is the typical model of its size class)AMSH1800VM1-D1 of 2 models have all five ratings · AHRI 210474672 | No models in this size class |
| Ducted, 2 tons | None on this board (0 of 2 models have all five ratings) | No models in this size class |
| Ducted, 2.5–3 tons | 75.5(50 is the typical model of its size class)AMSH2700VM1-D2 of 5 models have all five ratings · AHRI 210474675 | No models in this size class |
| Ducted, 3.5–4.5 tons | 63.5(50 is the typical model of its size class)AMSH4800VM1-D1 of 6 models have all five ratings · AHRI 210474681 | No models in this size class |
| Non-ducted, up to 1.5 tons | 75.9(50 is the typical model of its size class) (higher)ACSH1823VM2-Dwith ductless indoor unit AIWH1800VM2-D6 of 6 models have all five ratings · AHRI 209948207 | 70.8(50 is the typical model of its size class)048-TP-12K2V-23S-OUTwith ductless indoor unit 048-TP-12K2V-23S-IN10 of 16 models have all five ratings · AHRI 213927343 |
| Non-ducted, 2 tons | 56.2(50 is the typical model of its size class) (higher)ACSH2421VM2-Dwith ductless indoor unit AIWH2400VM2-D1 of 1 models have all five ratings · AHRI 209948204 | 53.0(50 is the typical model of its size class)048-TP-24K2V-20S-OUTwith ductless indoor unit 048-TP-24K2V-20S-IN2 of 3 models have all five ratings · AHRI 213927345 |
| Non-ducted, 2.5–3 tons | 67.1(50 is the typical model of its size class) (higher)AMSH2700VM1-D3 of 4 models have all five ratings · AHRI 210474674 | 29.5(50 is the typical model of its size class)048-TL-36K-MODU3 of 3 models have all five ratings · AHRI 211042067 |
| Non-ducted, 3.5–4.5 tons | 51.7(50 is the typical model of its size class)AMSH4800VM1-D1 of 1 models have all five ratings · AHRI 210474680 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | AIRDACH | Della |
|---|---|---|
| COP at 5°F | beats 96% · 2.38ACSH1823VM2-DNon-ducted, up to 1.5 tons | beats 89% · 2.21048-TP-18K2V-22S-OUTNon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 67% · 80%ACSH0924VM2-DNon-ducted, up to 1.5 tons | beats 64% · 77%048-TP-9K2V-23S-OUTNon-ducted, up to 1.5 tons |
| HSPF2 | beats 95% · 9.7AMSH4800VM1-DDucted, 3.5–4.5 tons | beats 57% · 9.5048-TP-12K2V-23S-OUTNon-ducted, up to 1.5 tons |
| SEER2 | beats 98% · 21.0AMSH2700VM1-DDucted, 2.5–3 tons | beats 79% · 23.5048-TP-9K2V-23S-OUTNon-ducted, up to 1.5 tons |
| EER2 | beats 85% · 14.0ACSH0924VM2-DNon-ducted, up to 1.5 tons | beats 68% · 13.0048-TP-9K2V-23S-OUTNon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 85% · 14,000 Btu/hAMSH1800VM1-DNon-ducted, up to 1.5 tons | beats 78% · 13,000 Btu/h048-TL-18K-MODUNon-ducted, up to 1.5 tons |