Skip to content

Airdach vs Della heat pumps

Measured against models of the same size and duct type, Della scores higher on 4 of the 6 ratings. Airdach has 29 outdoor models, Della has 94 outdoor models. Airdach has no QMID on file and is not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Airdach and Della on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Della scores higher on 4 of the 6 ratings.
  • Airdach
  • Della
  • Other ranked manufacturers
AirdachDella

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingAirdachDella
Efficiency index40%median —48%median — · 24th ranked
COP at 5°F48% (higher)median 1.9443% (higher)median 1.93 · 26th ranked
Capacity retention at 5°F34%median 71%44%median 73% · 21st ranked
HSPF228%median 7.550%median 9.5 · 16th ranked
SEER229%median 14.355%median 21.0 · 14th ranked
EER249% (higher)median 11.441% (higher)median 11.2 · 23rd ranked
Heating capacity at 5°F31%median 15,700 Btu/h46%median 12,250 Btu/h · 21st ranked
Outdoor models2994
AHRI certifications45133

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardAirdachDella
CEE 2025 Tier 1 (Split ASHP)24.1%7 models68.1%64 models
CEE 2026 Tier 1 (Split ASHP)24.1%7 models68.1%64 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)31%9 models66%62 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models43.6%41 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 7 groups where both have models
  • Airdach
  • Della
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeAirdachDella
Ducted, up to 1.5 tons2 · index —3 · index 67%
Ducted, 2 tons3 · index 36%2 · index 46%
Ducted, 2.5–3 tons7 · index 48%6 · index 65%
Ducted, 3.5–4.5 tons10 · index 54%6 · index 54%
Non-ducted, up to 1.5 tons5 · index 30%60 · index 46%
Non-ducted, 2 tons1 · index 25%13 · index 45%
Non-ducted, 2.5–3 tons1 · index 30%12 · index 42%
Non-ducted, 3.5–4.5 tonsNone5 · index 44%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeAirdachCold-climate score, best modelDellaCold-climate score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 2 models qualify)57.7(50 is the typical model of its size class)048-TLP-MODU-1D23 of 3 models qualify · AHRI 217568631
Ducted, 2 tonsNone on this board (0 of 3 models qualify)56.4(50 is the typical model of its size class)048-TCQ-MODU-1D32 of 2 models qualify · AHRI 218718736
Ducted, 2.5–3 tons59.2(50 is the typical model of its size class)A3TH36180OV1DGwith ducted air handler A3DH36000OE1DT1 of 7 models qualify · AHRI 21879704563.1(50 is the typical model of its size class) (higher)048-TPH-MODU-1D46 of 6 models qualify · AHRI 218718740
Ducted, 3.5–4.5 tons69.8(50 is the typical model of its size class) (higher)A3TH60180OV1DGwith ducted air handler A3DH60000OE1DT1 of 10 models qualify · AHRI 21879704663.6(50 is the typical model of its size class)048-TCQ-MODU-1D56 of 6 models qualify · AHRI 218718738
Non-ducted, up to 1.5 tons41.6(50 is the typical model of its size class)ACSH0920VR1-D3with ductless indoor unit AIWH0900VR1-D35 of 5 models qualify · AHRI 21710199270.9(50 is the typical model of its size class) (higher)048-TPH-MODU-1D342 of 60 models qualify · AHRI 218471007
Non-ducted, 2 tons13.5(50 is the typical model of its size class)ACSH2419VR1-D3with ductless indoor unit AIWH2400VR1-D31 of 1 models qualify · AHRI 21710199177.5(50 is the typical model of its size class) (higher)048-MS-24K2VR-22S-MX-OUTwith ductless indoor unit 048-MS-24K2VR-22S-MX-IN6 of 13 models qualify · AHRI 218043770
Non-ducted, 2.5–3 tons22.3(50 is the typical model of its size class)ACSH3621VR1-D3with ductless indoor unit AIWH3600VR1-D31 of 1 models qualify · AHRI 21710199068.0(50 is the typical model of its size class) (higher)048-TPH-MODU-1D48 of 12 models qualify · AHRI 218471008
Non-ducted, 3.5–4.5 tonsNo models in this size class48.1(50 is the typical model of its size class)048-TPH-MODU-1D64 of 5 models qualify · AHRI 218471010

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeAirdachAll-around score, best modelDellaAll-around score, best model
Ducted, up to 1.5 tonsNone on this board (0 of 2 models have all five ratings)72.9(50 is the typical model of its size class)048-TPH-MODU-1D33 of 3 models have all five ratings · AHRI 218718739
Ducted, 2 tons35.7(50 is the typical model of its size class)A4TH24152MN1DLwith ducted air handler A4DH2400ME1DT1 of 3 models have all five ratings · AHRI 21833177254.0(50 is the typical model of its size class) (higher)048-TCQ-MODU-1D32 of 2 models have all five ratings · AHRI 218718736
Ducted, 2.5–3 tons57.4(50 is the typical model of its size class)A3TH36180OV1DGwith ducted air handler A3DH36000OE1DT3 of 7 models have all five ratings · AHRI 21879704579.9(50 is the typical model of its size class) (higher)048-TPH-MODU-1D46 of 6 models have all five ratings · AHRI 218718740
Ducted, 3.5–4.5 tons59.5(50 is the typical model of its size class)A3TH60180OV1DGwith ducted air handler A3DH60000OE1DT4 of 10 models have all five ratings · AHRI 21879704667.5(50 is the typical model of its size class) (higher)048-TLP-MODU-1D56 of 6 models have all five ratings · AHRI 217568634
Non-ducted, up to 1.5 tons44.9(50 is the typical model of its size class)ACSH0920VR1-D3with ductless indoor unit AIWH0900VR1-D35 of 5 models have all five ratings · AHRI 21710199282.6(50 is the typical model of its size class) (higher)048-TPH-MODU-1D355 of 60 models have all five ratings · AHRI 218471007
Non-ducted, 2 tons24.5(50 is the typical model of its size class)ACSH2419VR1-D3with ductless indoor unit AIWH2400VR1-D31 of 1 models have all five ratings · AHRI 21710199168.1(50 is the typical model of its size class) (higher)048-MS-24K2VR-22S-MX-OUTwith ductless indoor unit 048-MS-24K2VR-22S-MX-IN12 of 13 models have all five ratings · AHRI 218043770
Non-ducted, 2.5–3 tons30.4(50 is the typical model of its size class)ACSH3621VR1-D3with ductless indoor unit AIWH3600VR1-D31 of 1 models have all five ratings · AHRI 21710199083.1(50 is the typical model of its size class) (higher)048-TPH-MODU-1D412 of 12 models have all five ratings · AHRI 218471008
Non-ducted, 3.5–4.5 tonsNo models in this size class70.2(50 is the typical model of its size class)048-TPH-MODU-1D65 of 5 models have all five ratings · AHRI 218471010

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingAirdachDella
COP at 5°Fbeats 86% · 2.30A4TH42152MN1DLDucted, 3.5–4.5 tonsbeats 89% · 2.27048-MS-24K2VR-21S-OUTNon-ducted, 2 tons
Capacity retention at 5°Fbeats 55% · 73%A3TH36180OV1DGDucted, 2.5–3 tonsbeats 95% · 105%048-TPH-MODU-1D3Ducted, up to 1.5 tons
HSPF2beats 64% · 8.8A3TH60180OV1DGDucted, 3.5–4.5 tonsbeats 96% · 10.5048-TPH-MODU-1D4Ducted, 2.5–3 tons
SEER2beats 76% · 18.0A3TH60180OV1DGDucted, 3.5–4.5 tonsbeats 99% · 26.5048-TPH-MODU-1D4Non-ducted, 2.5–3 tons
EER2beats 83% · 12.0A4TH48152MN1DLDucted, 3.5–4.5 tonsbeats 97% · 14.0048-TPH-MODU-1D4Non-ducted, 2.5–3 tons
Heating capacity at 5°Fbeats 69% · 12,100 Btu/hACSH1820VR1-D3Non-ducted, up to 1.5 tonsbeats 98% · 19,800 Btu/h048-TPH-MODU-1D3Non-ducted, up to 1.5 tons

More comparisons