Skip to content

Airlux vs TEXANAIR: heat pump ratings compared

Against heat pumps of the same size and type, a typical Airlux model beats 63% and a typical TEXANAIR model 53%. Airlux rates higher overall.

Covers older R-410A heat pumps, no longer installed new. See models sold today · Updated

Airlux

63%

of similar heat pumps beaten by its typical model

Well above average

13 models listed

TEXANAIR

53%

of similar heat pumps beaten by its typical model

About average

13 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FAirlux: Beats 57%TEXANAIR: Beats 53%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FAirlux: Beats 44%TEXANAIR: Beats 63%
  • Winter-long heating efficiencyHSPF2Airlux: Beats 73%TEXANAIR: Beats 80%
  • Summer-long cooling efficiencySEER2Airlux: Beats 74%TEXANAIR: Beats 53%
  • Hot-day cooling efficiencyEER2Airlux: Beats 58%TEXANAIR: Beats 28%

Average (50%)Dashed outline: the other brand, for comparison

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    Airlux
    77%
    TEXANAIR
    54%
  • Xcel CC

    Airlux
    46%
    TEXANAIR
    54%
  • CEE Advanced

    Airlux
    0%
    TEXANAIR
    0%
  • ENERGY STAR CC

    Airlux
    0%
    TEXANAIR
    0%

All-around best, ducted 2.5 to 3 tons

Showing Ducted, 2.5 to 3 tons (27,000 to 38,999 Btu/h cooling), the most-listed ducted size. Pick yours above. What size is my system?

Airlux

  1. 1AM3M27O/2022Airlux2.5 tons · 28,000 Btu/h · DuctedCold-climate pick, score 57.6Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    71% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.83 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.2 (HSPF2)
    Good
    Cooling efficiency
    21.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.7 (EER2)
    Good
    71.7score / 100Heating 58 · Cooling 86
  2. 2AM4M36O/2022Airlux3 tons · 36,000 Btu/h · DuctedNot a cold-climate pick: keeps 64% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    65% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.68 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.2 (HSPF2)
    Good
    Cooling efficiency
    20.0 (SEER2)
    Top 10%
    Hot-day cooling
    11.0 (EER2)
    Below the middle
    56.5score / 100Heating 44 · Cooling 69
  3. 3ASZ36O/2022with ducted air handler AMD36IAirlux3 tons · 36,000 Btu/h · DuctedNot a cold-climate pick: keeps 55% of its heat at 5°FMeets none of the standards tracked here
    Heat kept at 5°F
    55% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.91 (COP at 5°F)
    Good
    Winter efficiency
    8.8 (HSPF2)
    Good
    Cooling efficiency
    15.8 (SEER2)
    Below the middle
    Hot-day cooling
    8.8 (EER2)
    Below the middle
    37.7score / 100Heating 48 · Cooling 28

TEXANAIR

  1. 1TEXAN036HHCU2with ducted air handler TEXAN036AHU1TEXANAIR3 tons · 35,000 Btu/h · DuctedCold-climate pick, score 68.9Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    97% (Capacity at 5°F vs 47°F)
    Top 10%
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    16.3 (SEER2)
    Good
    Hot-day cooling
    11.7 (EER2)
    Good
    68.6score / 100Heating 69 · Cooling 68
  2. 2TEXAN036HHCU1with ducted air handler TEXANWM36A1TEXANAIR3 tons · 36,000 Btu/h · DuctedCold-climate pick, score 78.7Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    88% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.81 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.2 (HSPF2)
    Good
    Cooling efficiency
    17.6 (SEER2)
    Great
    Hot-day cooling
    10.2 (EER2)
    Below the middle
    57.5score / 100Heating 64 · Cooling 51
  3. 3TEXAN030HHCU1with ducted air handler TEXANDF36A1TEXANAIR2.5 tons · 30,000 Btu/h · DuctedCold-climate pick, score 68.2Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    82% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    1.85 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.7 (HSPF2)
    Great
    Cooling efficiency
    15.5 (SEER2)
    Below the middle
    Hot-day cooling
    10.5 (EER2)
    Below the middle
    52.5score / 100Heating 68 · Cooling 37

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

Advanced view: ranks, both brands’ models inside every size class, the standout model on each rating, cold-weather curves.

Open the advanced view

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter