Skip to content

AIRTEMP vs DIAL heat pumps

Measured against models of the same size and duct type, DIAL scores higher on 4 of the 6 ratings. AIRTEMP has 25 outdoor models, DIAL has 40 outdoor models. AIRTEMP and DIAL have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
AIRTEMP and DIAL on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, DIAL scores higher on 4 of the 6 ratings.
  • AIRTEMP
  • DIAL
  • Other ranked manufacturers
AIRTEMPDIAL

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingAIRTEMPDIAL
Efficiency index46%median —52%median —
COP at 5°F33%median 1.8141%median 1.80
Capacity retention at 5°F66% (higher)median 77%58% (higher)median 71%
HSPF237%median 8.552%median 9.0
SEER239%median 17.055%median 20.5
EER245%median 11.054%median 12.5
Heating capacity at 5°F64% (higher)median 19,800 Btu/h53% (higher)median 12,700 Btu/h
Outdoor models2540
AHRI certifications6250

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardAIRTEMPDIAL
CEE 2025 Tier 1 (Split ASHP)48%12 models90%36 models
CEE 2026 Tier 1 (Split ASHP)48%12 models90%36 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)52%13 models80%32 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate32%8 models42.5%17 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 7 groups where both have models
  • AIRTEMP
  • DIAL
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeAIRTEMPDIAL
Ducted, up to 1.5 tons2 · index 32%4 · index 50%
Ducted, 2 tons3 · index 53%4 · index 62%
Ducted, 2.5 to 3 tons6 · index 52%4 · index 72%
Ducted, 3.5 to 4.5 tons4 · index 63%2 · index 51%
Non-ducted, up to 1.5 tons8 · index 29%24 · index 45%
Non-ducted, 2 tons2 · index 58%8 · index 55%
Non-ducted, 2.5 to 3 tons5 · index 61%4 · index 64%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeAIRTEMPCold-climate score, best modelDIALCold-climate score, best model
Ducted, up to 1.5 tons36.3(50 is the typical model of its size class)GXH18(5.3)FMK4DH-11 of 2 models qualify · AHRI 21027681856.7(50 is the typical model of its size class) (higher)9000-UNI-Owith ducted air handler 9000Z-DUC-I3 of 4 models qualify · AHRI 206838609
Ducted, 2 tons50.3(50 is the typical model of its size class)GXH24(7.0)FMK4DH-11 of 2 models qualify · AHRI 21027681965.2(50 is the typical model of its size class) (higher)24000-UNI-Owith ducted air handler 24000Z-DUC-I4 of 4 models qualify · AHRI 206838612
Ducted, 2.5 to 3 tons55.4(50 is the typical model of its size class)GXH24-36MSK4DHwith ducted air handler GMH**-36MSK4DH14 of 7 models qualify · AHRI 20672440978.4(50 is the typical model of its size class) (higher)36000-UNI-Owith ducted air handler 36000U-DUC-I4 of 4 models qualify · AHRI 206838613
Ducted, 3.5 to 4.5 tons58.3(50 is the typical model of its size class)GXH48-60MSK4DHwith ducted air handler GMH48-**MSK4DH11 of 4 models qualify · AHRI 206724410None on this board (0 of 2 models qualify)
Non-ducted, up to 1.5 tons74.0(50 is the typical model of its size class)GXH18(5.3)FMK4DH-17 of 8 models qualify · AHRI 21027680580.3(50 is the typical model of its size class) (higher)9000-UNI-Owith ductless indoor unit 9000Z-CAS-I19 of 24 models qualify · AHRI 206838614
Non-ducted, 2 tons77.3(50 is the typical model of its size class) (higher)GXH24(7.0)FMK4DH-12 of 2 models qualify · AHRI 21027680673.4(50 is the typical model of its size class)24000-UNI-Owith ductless indoor unit 24000Z-CAS-IAlso listed as SZUN24WW2307 of 8 models qualify · AHRI 206838617
Non-ducted, 2.5 to 3 tons74.7(50 is the typical model of its size class)GXH42(12.3)FMK4DH-15 of 5 models qualify · AHRI 21027680478.2(50 is the typical model of its size class) (higher)36000-UNI-Owith ductless indoor unit 36000U-CAS-IAlso listed as SZUN36WW2304 of 4 models qualify · AHRI 206838618

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeAIRTEMPAll-around score, best modelDIALAll-around score, best model
Ducted, up to 1.5 tons31.8(50 is the typical model of its size class)GXH18(5.3)FMK4DH-11 of 2 models have all five ratings · AHRI 21027681858.1(50 is the typical model of its size class) (higher)9000-UNI-Owith ducted air handler 9000Z-DUC-I4 of 4 models have all five ratings · AHRI 206838609
Ducted, 2 tons60.8(50 is the typical model of its size class)GXH24-36MSK4DHwith ducted air handler GMH24-**MSK4DH12 of 3 models have all five ratings · AHRI 20672440872.5(50 is the typical model of its size class) (higher)24000Z-03-OAlso listed as MZME24WW3P230BBJ4 of 4 models have all five ratings · AHRI 204793304
Ducted, 2.5 to 3 tons53.0(50 is the typical model of its size class)GXH30(8.8)FMK4DH-13 of 6 models have all five ratings · AHRI 21027682078.7(50 is the typical model of its size class) (higher)36000Z-04-OAlso listed as MZME36WW4P230BAJ4 of 4 models have all five ratings · AHRI 204793305
Ducted, 3.5 to 4.5 tons63.3(50 is the typical model of its size class) (higher)GXH48-60MSK4DHwith ducted air handler GMH48-**MSK4DH11 of 4 models have all five ratings · AHRI 20672441057.1(50 is the typical model of its size class)48000-CHP-Owith ducted air handler 48000-CHP-AHU2 of 2 models have all five ratings · AHRI 207027469
Non-ducted, up to 1.5 tons58.6(50 is the typical model of its size class)GXH18(5.3)FMK4DH-18 of 8 models have all five ratings · AHRI 21027680566.4(50 is the typical model of its size class) (higher)9000-UNI-Owith ductless indoor unit 9000Z-CAS-I24 of 24 models have all five ratings · AHRI 206838614
Non-ducted, 2 tons72.2(50 is the typical model of its size class) (higher)GXH24(7.0)FMK4DH-12 of 2 models have all five ratings · AHRI 21027680672.1(50 is the typical model of its size class)24000Z-03-OAlso listed as MZME24WW3P230BBJ8 of 8 models have all five ratings · AHRI 204793306
Non-ducted, 2.5 to 3 tons70.9(50 is the typical model of its size class) (higher)GXH42(12.3)FMK4DH-15 of 5 models have all five ratings · AHRI 21027680470.2(50 is the typical model of its size class)36000Z-04-OAlso listed as MZME36WW4P230BAJ4 of 4 models have all five ratings · AHRI 204793307

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingAIRTEMPDIAL
COP at 5°Fbeats 89% · 2.21GXH18(5.3)FMK4DH-1Non-ducted, up to 1.5 tonsbeats 96% · 2.2836000-UNI-OAlso listed as SZUN36WW230Non-ducted, 2.5 to 3 tons
Capacity retention at 5°Fbeats 86% · 89%GXH30(8.8)FMK4DH-1Ducted, 2.5 to 3 tonsbeats 99% · 113%36000Z-04-OAlso listed as MZME36WW4P230BAJNon-ducted, 2.5 to 3 tons
HSPF2beats 82% · 10.0GXH36(10.6)FMK4DH-1Non-ducted, 2.5 to 3 tonsbeats 83% · 9.536000-UNI-ODucted, 2.5 to 3 tons
SEER2beats 83% · 24.0GXH12(3.5)LSK4DH2Non-ducted, up to 1.5 tonsbeats 96% · 21.024000Z-03-OAlso listed as MZME24WW3P230BBJDucted, 2 tons
EER2beats 84% · 12.5GXH30(8.8)FMK4DH-1Non-ducted, 2.5 to 3 tonsbeats 84% · 12.536000Z-04-OAlso listed as MZME36WW4P230BAJNon-ducted, 2.5 to 3 tons
Heating capacity at 5°Fbeats 87% · 14,500 Btu/hGXH18(5.3)LSK4DH2Non-ducted, up to 1.5 tonsbeats 93% · 36,000 Btu/h36000Z-04-OAlso listed as MZME36WW4P230BAJDucted, 2.5 to 3 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter