Skip to content

ApooDr vs HAIER heat pumps

Measured against models of the same size and duct type, HAIER scores higher on 4 of the 6 ratings. ApooDr has 52 outdoor models, HAIER has 53 outdoor models. ApooDr and HAIER have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
ApooDr and HAIER on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, HAIER scores higher on 4 of the 6 ratings.
  • ApooDr
  • HAIER
  • Other ranked manufacturers
ApooDrHAIER

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingApooDrHAIER
Efficiency index43%median —45%median —
COP at 5°F42% (higher)median 1.8034% (higher)median 1.80
Capacity retention at 5°F37%median 65%48%median 72%
HSPF245%median 8.857%median 9.5
SEER248% (higher)median 19.047% (higher)median 20.0
EER238%median 10.540%median 12.0
Heating capacity at 5°F37%median 11,600 Btu/h51%median 15,454 Btu/h
Outdoor models5253
AHRI certifications62112

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardApooDrHAIER
CEE 2025 Tier 1 (Split ASHP)69.2%36 models49.1%26 models
CEE 2026 Tier 1 (Split ASHP)57.7%30 models49.1%26 models
CEE Advanced Tier (Split ASHP)0%0 models7.5%4 models
Xcel Energy Colorado cold-climate ASHP (2025)38.5%20 models41.5%22 models
DOE Cold Climate Heat Pump Challenge0%0 models7.5%4 models
ENERGY STAR Cold Climate21.2%11 models30.2%16 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • ApooDr
  • HAIER
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeApooDrHAIER
Ducted, up to 1.5 tons2 · index 47%6 · index 36%
Ducted, 2 tons1 · index 52%6 · index 42%
Ducted, 2.5 to 3 tons4 · index 55%7 · index 38%
Ducted, 3.5 to 4.5 tons3 · index 56%6 · index 34%
Ducted, 5 tons and up1 · index 42%None
Non-ducted, up to 1.5 tons30 · index 42%27 · index 57%
Non-ducted, 2 tons6 · index 33%10 · index 48%
Non-ducted, 2.5 to 3 tons8 · index 39%7 · index 34%
Non-ducted, 3.5 to 4.5 tons2 · index 44%5 · index 15%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeApooDrCold-climate score, best modelHAIERCold-climate score, best model
Ducted, up to 1.5 tons52.6(50 is the typical model of its size class)AM2OA-18HFN11 of 2 models qualify · AHRI 20915709653.8(50 is the typical model of its size class) (higher)2U20EH2HD**4 of 6 models qualify · AHRI 210151026
Ducted, 2 tons63.2(50 is the typical model of its size class) (higher)AHU19-24HN1-MRwith ducted air handler AHU19-24HN1-M1 of 1 models qualify · AHRI 20927030857.6(50 is the typical model of its size class)3U24EH2HD**2 of 6 models qualify · AHRI 210082199
Ducted, 2.5 to 3 tons57.6(50 is the typical model of its size class)AM3OJ-27HFN11 of 4 models qualify · AHRI 20915709961.9(50 is the typical model of its size class) (higher)4U36EH2HD**2 of 7 models qualify · AHRI 210151027
Ducted, 3.5 to 4.5 tonsNone on this board (0 of 3 models qualify)53.6(50 is the typical model of its size class)1U4248LP2HD**with ducted air handler USYM42UCDD1 of 6 models qualify · AHRI 211729105
Ducted, 5 tons and upNone on this board (0 of 1 models qualify)No models in this size class
Non-ducted, up to 1.5 tons86.6(50 is the typical model of its size class)AGN24-09H220V1Bwith ductless indoor unit AGN24-09H220V1A16 of 30 models qualify · AHRI 20915709096.0(50 is the typical model of its size class) (higher)1U12EH2HE**with ductless indoor unit AW12EH2HE14 of 27 models qualify · AHRI 212409448
Non-ducted, 2 tons56.8(50 is the typical model of its size class)AGN24-24H1Bwith ductless indoor unit AGN24-24H1A1 of 6 models qualify · AHRI 20915709463.3(50 is the typical model of its size class) (higher)3U24EH2HD**4 of 10 models qualify · AHRI 210082198
Non-ducted, 2.5 to 3 tons51.5(50 is the typical model of its size class)AM3OJ-27HFN11 of 8 models qualify · AHRI 20915709868.2(50 is the typical model of its size class) (higher)4U36EH2HD**3 of 7 models qualify · AHRI 210082201
Non-ducted, 3.5 to 4.5 tonsNone on this board (0 of 2 models qualify)19.1(50 is the typical model of its size class)1U4248LP2HD**with ductless indoor unit USYL42UCDD1 of 5 models qualify · AHRI 211744605

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeApooDrAll-around score, best modelHAIERAll-around score, best model
Ducted, up to 1.5 tons59.8(50 is the typical model of its size class) (higher)AM2OA-18HFN12 of 2 models have all five ratings · AHRI 20915709645.0(50 is the typical model of its size class)1U09EH2HE**with ducted air handler USYM09UCDSA5 of 6 models have all five ratings · AHRI 212409472
Ducted, 2 tons51.9(50 is the typical model of its size class)AHU19-24HN1-MRwith ducted air handler AHU19-24HN1-M1 of 1 models have all five ratings · AHRI 20927030854.0(50 is the typical model of its size class) (higher)3U24EH2HD**3 of 6 models have all five ratings · AHRI 210082199
Ducted, 2.5 to 3 tons71.7(50 is the typical model of its size class) (higher)AM3OJ-27HFN14 of 4 models have all five ratings · AHRI 20915709944.4(50 is the typical model of its size class)4U36EH2HD**4 of 7 models have all five ratings · AHRI 210151027
Ducted, 3.5 to 4.5 tons63.5(50 is the typical model of its size class) (higher)AM5OG-48HFN13 of 3 models have all five ratings · AHRI 20915710538.5(50 is the typical model of its size class)1U4248LP2HD**with ducted air handler USYM42UCDD4 of 6 models have all five ratings · AHRI 211729105
Ducted, 5 tons and up41.9(50 is the typical model of its size class)AHU19-60HN1-MRwith ducted air handler AHU19-60HN1-M1 of 1 models have all five ratings · AHRI 209270312No models in this size class
Non-ducted, up to 1.5 tons87.1(50 is the typical model of its size class)AGN24-09H220V1Bwith ductless indoor unit AGN24-09H220V1A30 of 30 models have all five ratings · AHRI 20915709095.4(50 is the typical model of its size class) (higher)1U09EH2VHE*with ductless indoor unit AW09EH2VHD21 of 27 models have all five ratings · AHRI 206445819
Non-ducted, 2 tons67.4(50 is the typical model of its size class) (higher)AGN24-24H1Bwith ductless indoor unit AGN24-24H1A6 of 6 models have all five ratings · AHRI 20915709460.7(50 is the typical model of its size class)3U24MS2HD**7 of 10 models have all five ratings · AHRI 207698998
Non-ducted, 2.5 to 3 tons68.0(50 is the typical model of its size class) (higher)AM3OJ-27HFN17 of 8 models have all five ratings · AHRI 20915709849.7(50 is the typical model of its size class)4U36EH2HD**5 of 7 models have all five ratings · AHRI 210082201
Non-ducted, 3.5 to 4.5 tons48.3(50 is the typical model of its size class) (higher)AM5OG-48HFN12 of 2 models have all five ratings · AHRI 20915710418.2(50 is the typical model of its size class)5U42MS2HD**4 of 5 models have all five ratings · AHRI 210404027

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingApooDrHAIER
COP at 5°Fbeats 97% · 2.22AGN24-24H1BNon-ducted, 2 tonsbeats 94% · 2.341U18EH2HE**Non-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 73% · 86%AGN24-09H220V1BNon-ducted, up to 1.5 tonsbeats 97% · 120%1U09EH2VHE*Non-ducted, up to 1.5 tons
HSPF2beats 95% · 9.7AM5OG-48HFN1Ducted, 3.5 to 4.5 tonsbeats 99% · 14.01U09EH2VHE*Non-ducted, up to 1.5 tons
SEER2beats 98% · 21.0AM3OJ-27HFN1Ducted, 2.5 to 3 tonsbeats 100% · 30.01U09EH2VHE*Non-ducted, up to 1.5 tons
EER2beats 90% · 14.7AGN24-09H220V1BNon-ducted, up to 1.5 tonsbeats 97% · 16.01U09EH2VHE*Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 79% · 13,000 Btu/hATM19-18H2DNon-ducted, up to 1.5 tonsbeats 96% · 20,000 Btu/h1U18EH2HE**Non-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
ApooDr vs HAIER: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,710 models (37.8% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • ApooDr (median, middle 50%)
  • HAIER (median, middle 50%)
Heating capacity, % of its 47°F maximum59%73%COP at maximum capacity1.991.80

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,710100%100%100%100%100%
All rated models, 17°F3,71065%68%76%83%92%
All rated models, 5°F3,71055%58%66%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7102.642.873.13.323.53
All rated models, 17°F3,7101.982.052.22.342.49
All rated models, 5°F3,7101.81.831.922.032.21
ApooDr: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
ApooDr, 47°F23100%100%100%100%100%
ApooDr, 17°F2363%67%70%73%75%
ApooDr, 5°F2354%55%59%64%65%
ApooDr: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
ApooDr, 47°F232.652.953.043.243.43
ApooDr, 17°F231.982.112.22.442.65
ApooDr, 5°F231.81.831.992.092.22
HAIER: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
HAIER, 47°F18100%100%100%100%100%
HAIER, 17°F1864%65%69%80%83%
HAIER, 5°F1856%66%73%80%85%
HAIER: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
HAIER, 47°F182.893.013.353.64.21
HAIER, 17°F182.142.32.492.52.62
HAIER, 5°F181.81.81.81.942.09

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter