Both views use the same certified data. This device remembers your choice.
ApooDr vs HAIER heat pumps
Measured against models of the same size and duct type, ApooDr and HAIER split the 6 ratings 3 to 3. ApooDr has 44 outdoor models, HAIER has 38 outdoor models. ApooDr and HAIER have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- ApooDr
- HAIER
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | ApooDr | HAIER |
|---|---|---|
| Efficiency index | 59% (higher)median — | 51% (higher)median — |
| COP at 5°F | 64% (higher)median 2.01 | 32% (higher)median 1.80 |
| Capacity retention at 5°F | 46%median 71% | 62%median 80% |
| HSPF2 | 66%median 9.6 | 68%median 9.5 |
| SEER2 | 65% (higher)median 20.1 | 53% (higher)median 20.0 |
| EER2 | 55% (higher)median 12.0 | 42% (higher)median 12.0 |
| Heating capacity at 5°F | 53%median 17,950 Btu/h | 64%median 19,950 Btu/h |
| Outdoor models | 44 | 38 |
| AHRI certifications | 61 | 2,395 |
Share of models meeting each standard
| Standard | ApooDr | HAIER |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 90.9%40 models | 94.7%36 models |
| CEE 2026 Tier 1 (Split ASHP) | 86.4%38 models | 84.2%32 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 75%33 models | 81.6%31 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 77.3%34 models | 71.1%27 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- ApooDr
- HAIER
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | ApooDr | HAIER |
|---|---|---|
| Ducted, up to 1.5 tons | 5 · index 71% | 9 · index 52% |
| Ducted, 2 tons | 4 · index 67% | 6 · index 45% |
| Ducted, 2.5 to 3 tons | 6 · index 61% | 8 · index 52% |
| Ducted, 3.5 to 4.5 tons | 7 · index 64% | 7 · index 54% |
| Ducted, 5 tons and up | 2 · index 65% | 1 · index 75% |
| Non-ducted, up to 1.5 tons | 19 · index 60% | 14 · index 49% |
| Non-ducted, 2 tons | 5 · index 53% | 5 · index 51% |
| Non-ducted, 2.5 to 3 tons | 4 · index 43% | 5 · index 45% |
| Non-ducted, 3.5 to 4.5 tons | 2 · index 43% | 2 · index 50% |
| Non-ducted, 5 tons and up | 1 · index 27% | 1 · index 68% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | ApooDrCold-climate score, best model | HAIERCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 81.6(50 is the typical model of its size class) (higher)ALC24-09H1Bwith ducted air handler DIU-09HWFN104 of 5 models qualify · AHRI 217563492 | 68.2(50 is the typical model of its size class)2Q20RT2BE**9 of 9 models qualify · AHRI 217021965 |
| Ducted, 2 tons | 77.1(50 is the typical model of its size class) (higher)ALC24-24H1Bwith ducted air handler DIU-24HWFN104 of 4 models qualify · AHRI 217563495 | 74.5(50 is the typical model of its size class)1U24T3PS*HEwith ducted air handler PE(S,T)35J5 of 6 models qualify · AHRI 218857291 |
| Ducted, 2.5 to 3 tons | 77.7(50 is the typical model of its size class)AHU3G-36HFN-Bwith ducted air handler AHU3G-36HFN-A4 of 6 models qualify · AHRI 217563475 | 79.1(50 is the typical model of its size class) (higher)AU36VFPTYA6 of 8 models qualify · AHRI 218394141 |
| Ducted, 3.5 to 4.5 tons | 78.1(50 is the typical model of its size class)AM6OG-48HFN17 of 7 models qualify · AHRI 217563515 | 80.4(50 is the typical model of its size class) (higher)AU48VFPTYA5 of 7 models qualify · AHRI 218394142 |
| Ducted, 5 tons and up | None on this board (0 of 2 models qualify) | 81.8(50 is the typical model of its size class)AU60VFPTYA1 of 1 models qualify · AHRI 218394143 |
| Non-ducted, up to 1.5 tons | 85.7(50 is the typical model of its size class) (higher)ASG24-09H220V1Bwith ductless indoor unit ASG24-09H220V1A15 of 19 models qualify · AHRI 217563488 | 67.4(50 is the typical model of its size class)1Q09RT2BE**with ductless indoor unit US09AB2BE14 of 14 models qualify · AHRI 218073018 |
| Non-ducted, 2 tons | 75.9(50 is the typical model of its size class) (higher)ALC24-24H1Bwith ductless indoor unit CCA22-24HRFN15 of 5 models qualify · AHRI 217563502 | 62.9(50 is the typical model of its size class)3Q24RT2BE**4 of 5 models qualify · AHRI 217009757 |
| Non-ducted, 2.5 to 3 tons | 63.6(50 is the typical model of its size class)ALC24-36H1Bwith ductless indoor unit CCA22-36HRFN12 of 4 models qualify · AHRI 217563503 | 74.4(50 is the typical model of its size class) (higher)AU36VFPTYA4 of 5 models qualify · AHRI 218394138 |
| Non-ducted, 3.5 to 4.5 tons | 60.8(50 is the typical model of its size class)AM6OG-48HFN12 of 2 models qualify · AHRI 217563516 | 67.6(50 is the typical model of its size class) (higher)AU48VFPTYA2 of 2 models qualify · AHRI 218394139 |
| Non-ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 64.2(50 is the typical model of its size class)AU60VFPTYA1 of 1 models qualify · AHRI 218394140 |
All-around best
| Size and duct type | ApooDrAll-around score, best model | HAIERAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 81.1(50 is the typical model of its size class) (higher)ALC24-09H1Bwith ducted air handler DIU-09HWFN105 of 5 models have all five ratings · AHRI 217563492 | 66.5(50 is the typical model of its size class)1Q09RT2BE**with ducted air handler US09MB2BE9 of 9 models have all five ratings · AHRI 217036491 |
| Ducted, 2 tons | 78.9(50 is the typical model of its size class) (higher)ALC24-24H1Bwith ducted air handler DIU-24HWFN104 of 4 models have all five ratings · AHRI 217563495 | 67.3(50 is the typical model of its size class)1U24T3PS*HEwith ducted air handler NAM30E3TA56 of 6 models have all five ratings · AHRI 217270222 |
| Ducted, 2.5 to 3 tons | 75.1(50 is the typical model of its size class) (higher)AHU3G-36HFN-Bwith ducted air handler AHU3G-36HFN-A6 of 6 models have all five ratings · AHRI 217563475 | 75.0(50 is the typical model of its size class)AU36VFPTYA8 of 8 models have all five ratings · AHRI 218394141 |
| Ducted, 3.5 to 4.5 tons | 85.3(50 is the typical model of its size class) (higher)AM6OG-48HFN17 of 7 models have all five ratings · AHRI 217563515 | 70.2(50 is the typical model of its size class)AU48VFPTYA7 of 7 models have all five ratings · AHRI 218394142 |
| Ducted, 5 tons and up | 65.9(50 is the typical model of its size class)ALC24-60H1Bwith ducted air handler DIU-60HWFN102 of 2 models have all five ratings · AHRI 217563498 | 74.8(50 is the typical model of its size class) (higher)AU60VFPTYA1 of 1 models have all five ratings · AHRI 218394143 |
| Non-ducted, up to 1.5 tons | 86.8(50 is the typical model of its size class) (higher)ASG24-09H220V1Bwith ductless indoor unit ASG24-09H220V1A19 of 19 models have all five ratings · AHRI 217563488 | 78.7(50 is the typical model of its size class)1Q09RT2BE**with ductless indoor unit US09AB2BE14 of 14 models have all five ratings · AHRI 218073018 |
| Non-ducted, 2 tons | 68.9(50 is the typical model of its size class) (higher)ALC24-24H1Bwith ductless indoor unit CCA22-24HRFN15 of 5 models have all five ratings · AHRI 217563502 | 68.8(50 is the typical model of its size class)3Q24RT2BE**5 of 5 models have all five ratings · AHRI 217009757 |
| Non-ducted, 2.5 to 3 tons | 59.3(50 is the typical model of its size class)AM5OG-36HFN14 of 4 models have all five ratings · AHRI 217563511 | 76.7(50 is the typical model of its size class) (higher)AU36VFPTYA5 of 5 models have all five ratings · AHRI 218394138 |
| Non-ducted, 3.5 to 4.5 tons | 53.1(50 is the typical model of its size class)AM6OG-48HFN12 of 2 models have all five ratings · AHRI 217563516 | 73.9(50 is the typical model of its size class) (higher)AU48VFPTYA2 of 2 models have all five ratings · AHRI 218394139 |
| Non-ducted, 5 tons and up | 32.9(50 is the typical model of its size class)AM6OG-55HFN11 of 1 models have all five ratings · AHRI 217563517 | 68.0(50 is the typical model of its size class) (higher)AU60VFPTYA1 of 1 models have all five ratings · AHRI 218394140 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | ApooDr | HAIER |
|---|---|---|
| COP at 5°F | beats 99% · 2.51ALC24-12H1BNon-ducted, up to 1.5 tons | beats 93% · 2.491U36T3PC*HEDucted, 2.5 to 3 tons |
| Capacity retention at 5°F | beats 94% · 100%AHU3G-48HFN-BDucted, 3.5 to 4.5 tons | beats 97% · 82%AU60VFPTYADucted, 5 tons and up |
| HSPF2 | beats 98% · 10.8AHU3G-30HFN-BDucted, 2.5 to 3 tons | beats 100% · 13.5AU36VFPTYADucted, 2.5 to 3 tons |
| SEER2 | beats 96% · 20.4AM6OG-48HFN1Ducted, 3.5 to 4.5 tons | beats 95% · 27.01Q09RT2BE**Non-ducted, up to 1.5 tons |
| EER2 | beats 91% · 13.3ALC24-18H1BDucted, up to 1.5 tons | beats 99% · 14.4AU36VFPTYANon-ducted, 2.5 to 3 tons |
| Heating capacity at 5°F | beats 98% · 54,000 Btu/hAHU3G-50HFN-BAlso listed as AHU3G-60HFN-BDucted, 3.5 to 4.5 tons | beats 99% · 20,000 Btu/h2Q20RT2BE**Ducted, up to 1.5 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- ApooDr (median, middle 50%)
- HAIER (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| ApooDr, 47°F | 44 | 100% | 100% | 100% | 100% | 100% |
| ApooDr, 17°F | 44 | 65% | 67% | 72% | 74% | 80% |
| ApooDr, 5°F | 44 | 57% | 59% | 63% | 67% | 82% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| ApooDr, 47°F | 44 | 2.77 | 2.98 | 3.16 | 3.47 | 3.69 |
| ApooDr, 17°F | 44 | 2.12 | 2.2 | 2.27 | 2.46 | 2.59 |
| ApooDr, 5°F | 44 | 1.84 | 1.93 | 2.01 | 2.15 | 2.3 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| HAIER, 47°F | 35 | 100% | 100% | 100% | 100% | 100% |
| HAIER, 17°F | 35 | 59% | 60% | 64% | 76% | 80% |
| HAIER, 5°F | 35 | 63% | 70% | 73% | 81% | 91% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| HAIER, 47°F | 35 | 3.08 | 3.2 | 3.5 | 3.65 | 3.76 |
| HAIER, 17°F | 35 | 2.21 | 2.4 | 2.5 | 2.6 | 2.8 |
| HAIER, 5°F | 35 | 1.8 | 1.8 | 1.8 | 1.83 | 2.06 |
Source: NEEP ccASHP list · as of